Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Hent hele databladet som PDF:
Uddrag af datablad: Tekniske data for
P-LB-1.E.23
General specifications |
Number of protected signal lines | 2 |
Functional safety related parameters |
Safety Integrity Level (SIL) | SIL 3 |
Signal lines |
Connection | terminals 2, 3 |
Rated voltage | max. 30 V |
Rated current | max. 250 mA |
Leakage current | max. 5 µA |
On-state voltage | max. 45 V |
Ground insulation | max. 500 V breakdown voltage |
Conformity |
Degree of protection | IEC 60529:2001 |
Ambient conditions |
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Mechanical specifications |
Degree of protection | IP20 |
Mass | approx. 70 g |
Dimensions | 20 x 104 x 127 mm (0.8 x 4.1 x 5 inch) (W x H x D) |
| Height | 104 mm |
| Width | 20 mm |
| Depth | 127 mm |
Mounting | on the KF module |
Data for application in connection with hazardous areas |
EU-type examination certificate | PTB 02 ATEX 2044 |
| Marking | II (1)G [Ex ia Ga] IIC |
| Voltage | 30 V |
| Current | 250 mA |
| Internal capacitance | negligible |
| Internal inductance | 200 µH |
Maximum leakage current | 10 kA (8/20 µs) per conductor |
Nominal response time | |
| Symmetrical | 1 ns |
| Asymmetric | 100 ns |
Series resistor | ≤ 0.5 Ω per wire |
Bandwidth | ≥ 40 kHz |
Certificate | PF 16 CERT 3908 X |
| Marking | II 3G Ex nA IIC T4 Gc |
Directive conformity | |
| Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 |
International approvals |
IECEx approval | |
| IECEx certificate | IECEx BAS 12.0123 |
| IECEx marking | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I |
General information |
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
Classifications
System | Classcode |
ECLASS 13.0 | 27171202 |
ECLASS 12.0 | 27171202 |
ECLASS 11.0 | 27130805 |
ECLASS 10.0.1 | 27130805 |
ECLASS 9.0 | 27130805 |
ECLASS 8.0 | 27130805 |
ECLASS 5.1 | 27130801 |
ETIM 9.0 | EC000941 |
ETIM 8.0 | EC000941 |
ETIM 7.0 | EC000941 |
ETIM 6.0 | EC000941 |
ETIM 5.0 | EC000941 |
UNSPSC 12.1 | 39121610 |
Details:
P-LB-1.E.23
Product Documentation:
P-LB-1.E.23
Design / Simulation:
P-LB-1.E.23
Tilhørende produkter:
P-LB-1.E.23
Accessories |
|
|
|
Accessory Zener Barriers, Accessory Surge Protection, For individual grounding through insulated mounting, Packaging unit: 10 piecespa |
|
|
|
|
Accessory Zener Barriers, Accessory Surge Protection, For individual grounding through insulated mountingpa |
|
|
|
|
Accessory Zener Barriers, Accessory Surge Protection, For individual grounding through insulated mountingpa |
|