Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Hent hele databladet som PDF:
General specifications | ||
---|---|---|
Measuring method | The device is a measuring system that functions according to the time-of-flight method. The distance from the reference point (process connection of the measuring device) to the product surface is measured. | |
Construction type | compact device | |
Series | LCR | |
Supply | ||
Rated voltage | 10.5 ... 30 V DC | |
Current consumption | input current : max. 25 mA start-up current : max. 3.6 mA |
|
Power consumption | input power : max. 675 mW | |
Electrical specifications | ||
Surge protection | integrated | |
Start-up time | first stable measured value after 20 s at 24 V DC | |
Interface | ||
Interface type | Bluetooth | |
Detection range | max. 25 m | |
Configuration | commissioning, operation and maintenance via P+F Level app - can be activated/deactivated - password encryption |
|
Communication | encrypted | |
Input | ||
Measured variable | distance between reference point and product surface | |
Measuring range | - device with 40 mm (1.5 inch) antenna: max. 8 m (26 foot) - device with 40 mm (1.5 inch) antenna and flooding protection tube (accessory): max. 12 m (39 foot) |
|
Operating frequency | approx. 26 GHz , K-Band | |
Transmitter radiated power | mean power density in the direction of the beam - at a distance of 1 m (3.3 foot): < 12 nW/cm2 - at a distance of 5 m (16 foot): < 0.4 nW/cm2 |
|
Output | ||
Output signal | 4 ... 20 mA , measured value output and power supply | |
Signal on alarm | current output: 22.5 mA (in accordance with NAMUR recommendation NE 43) P+F Level (app) - status signal (as per NAMUR Recommendation NE 107) - plain text display with remedial action |
|
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Low voltage | ||
Directive 2014/35/EU | EN 61010-1:2010 | |
Conformity | ||
Electromagnetic compatibility | NE 21 | |
Degree of protection | IEC 60529:2001 | |
Vibration resistance | DIN EN 60068-2-64 / IEC 60068-2-64 | |
Climate class | DIN EN 60068-2-38/IEC 68-2-38 | |
Bluetooth | IEEE 802.15.1 | |
Measurement accuracy | ||
Accuracy | up to ± 5 mm | |
Operating conditions | ||
Process conditions | ||
Process temperature | -40 ... 60 °C (-40 ... 140 °F) | |
Process pressure | relative pressure : -1 ... 3 bar (-14.5 ... 43.5 psi) absolute pressure : < 4 bar (58 psi) |
|
State of aggregation | liquid | |
Dielectric constant | 4 ... 10 , e. g. concentrated acid, organic solvents, ester, aniline, alcohol, acetone, ... > 10 , e.g. conductive liquids, aqueous solutions, diluted acids and bases |
|
Ambient conditions | ||
Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) | |
Storage temperature | -40 ... 80 °C (-40 ... 176 °F) | |
Vibration resistance | 20 ... 2000 Hz, 1 (m/s2)2/Hz | |
Mechanical specifications | ||
Degree of protection | IP68, NEMA 6P (24 hours in water 1.83 m (6 ft) deep) IP66, NEMA 4X |
|
Connection | cable 2 x 0,75 mm2 | |
Material | sensor housing: PVDF seal: EPDM back side process connection: PVDF cable gland: PA conduit adapter: CuZn nickel-plated O-ring: EPDM counter nut: PA6.6 design ring: PBT-PC front side process connection: PVDF cable: PVC |
|
Cable | ||
Length | 10 m | |
Mass | approx. 3 kg | |
Dimensions | ∅75 x 140 mm | |
Length | 140 mm | |
Diameter | 75 mm | |
Process connection | Back side: thread ISO228 G1, ASME MNPT1 Front side: thread ISO228 G1-1/2, ASME MNPT1-1/2 |
|
Certificates and approvals | ||
Telecommunications | radio license FCC | |
General information | ||
Supplementary documentation | technical information (TI) manuals, brief instructions (BA, KA) |
|
Accessories | ||
Designation | see technical information (TI) |
System | Classcode |
---|---|
ECLASS 13.0 | 27200513 |
ECLASS 12.0 | 27200513 |
ECLASS 11.0 | 27200513 |
ECLASS 10.0.1 | 27200513 |
ECLASS 9.0 | 27200513 |
ECLASS 8.0 | 27200513 |
ECLASS 5.1 | 27200513 |
ETIM 9.0 | EC002995 |
ETIM 8.0 | EC002995 |
ETIM 7.0 | EC002995 |
ETIM 6.0 | EC002995 |
ETIM 5.0 | EC001447 |
UNSPSC 12.1 | 41111950 |
Product information | Sprog | Fil type | Fil størrelse |
---|---|---|---|
TI01266O Technical information LCR10 | ENG | 2726 KB | |
Brief Instructions | |||
KA01247O, Brief instructions LCR10 | ENG | 3282 KB | |
Manuals | |||
BA01577O, Manual LCR10 | ENG | 3889 KB |
Certificates | Certifikat nr. | Sprog | Fil type | Fil størrelse |
---|---|---|---|---|
Canada Radio Approval | 7037A-2KL | ALL | 1256 KB | |
Canada Radio Approval | 7037A-2KT | ALL | 1256 KB | |
USA FCC Approval | IRELCR2XKT | ALL | 183 KB | |
USA FCC Approval | IRELCR2XKL | ALL | 186 KB | |
USA FCC Approval | IRELCR2XKL | ALL | 183 KB | |
USA FCC Approval | IRELCR2XKT | ALL | 183 KB | |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-4999 | ALL | 84 KB |