Support Industrielle sensorer
Support Explosion Protection

RFID read/write device IUT-F191-IO-V1-FR1-01

IUT-F191-IO-V1-FR1-01
  • Flexible UHF read/write device with short detection range
  • Ready-made PLC function blocks designed for quick and easy system integration
  • Compact and robust housing for harsh industrial environments
  • Multi-tag reading of up to 20 tags ensures increased productivity
  • Circular antenna polarization ensures reliable transponder detection and improves process flow
  • For connection to IO-Link master
  • Degree of protection IP67

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Hent hele databladet som PDF:


Uddrag af datablad: Tekniske data for   IUT-F191-IO-V1-FR1-01

Produkt beskrivelse
UHF RFID read/write device with IO-Link, Europe
General specifications
Operating frequency865 … 868 MHz: EU, Turkey
Transmission licenses for other countries on request
Emitted power3 … 100 mW ERP adjustable
MTBF127 a (Operation at +40 °C)
Indicators/operating means
LED green/redSolid green: Ready for operation, no IO-Link communication
Flashing green (1 Hz): IO-Link operation
LED yellowRead/write operation successful
LED blueTransmission mode
Electrical specifications
Operating voltage18 ... 30 V DC (IO-Link)
Current consumption≤ 90 mA ( at 24 V DC )
Interface
Interface typeIO-Link
IO-Link revision1.1
Device profileIdentification and Diagnosis - I&D
Process dataInput 32 Byte
Output 32 Byte
Vendor ID1 (0x0001)
Device ID4194817 (0x400201)
Data transfer rateCOM3 (230.4 kbits/s)
Min. cycle time4 ms
SIO mode supportno
Compatible master port typeClass A
Class B
Directive conformity
Radio equipment
Directive 2014/53/EUEN 301489-1
EN 301489-3
EN 302208
EN 62368-1
EN 50364
RoHS
Directive 2011/65/EU (RoHS)IEC/EN 63000
Standard conformity
Degree of protectionEN 60529
Communication interfaceIEC 61131-9 / IO-Link V1.1.3
RFIDISO/IEC 18000-63
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F) (Operation with nontransmission periods)
-25 ... 60 °C (-13 ... 140 °F) (Continuous transmission mode)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Degree of protectionIP67
Connectionconnector M12 x 1
Material
HousingPA 6.6
BaseAluminum
Mass700 g
Dimensions
Height47 mm
Width165 mm
Length165 mm

Classifications

SystemClasscode
ECLASS 13.027280401
ECLASS 12.027280401
ECLASS 11.027280401
ECLASS 10.0.127280401
ECLASS 9.027280401
ECLASS 8.027280401
ECLASS 5.127280401
ETIM 9.0EC002998
ETIM 8.0EC002998
ETIM 7.0EC002998
ETIM 6.0EC002998
ETIM 5.0EC002998
UNSPSC 12.143211710

Details: IUT-F191-IO-V1-FR1-01

Informative Literature: IUT-F191-IO-V1-FR1-01

Language Selection:
LiteratureSprogFil typeFil størrelse
Application Report - RFID Systems in Industrial Metal StampingENGPDF1773 KB

Product Documentation: IUT-F191-IO-V1-FR1-01

Language Selection:
ManualsSprogFil typeFil størrelse
Manual IUT-F191-IO-V1-FR*ENGPDF9393 KB
Parameter Information
IO-Link Parameter Datasheet IUT-F191-IO-V1-FR1-01 / IO-Link-Parameter-Datenblatt IUT-F191-IO-V1-FR1-01ALLPDF531 KB

Design / Simulation: IUT-F191-IO-V1-FR1-01

Language Selection:
CADSprogFil typeFil størrelse
CAD 3-D / CAD 3-DALLSTP1114 KB

Approvals: IUT-F191-IO-V1-FR1-01

Language Selection:
CertificatesCertifikat nr.SprogFil typeFil størrelse
IO-Link Manufacturer DeclarationCERT-6856ALLPDF363 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-7064ALLPDF109 KB
Simplified EU Declaration of Conformity / Vereinfachte EU-Konformitätserklärung   ALLPDF61 KB
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F)DOC-7065ALLPDF107 KB

Tilhørende produkter: IUT-F191-IO-V1-FR1-01

Accessories

EtherNet/IP IO-Link master with 8 inputs/outputsfa

PROFINET IO IO-Link master with 8 inputs/outputsfa

Cordset M12 socket straight to M12 plug straight A-coded, 4-pin, PVC cable greyfa
Ethernet IO-Link module with 8 inputs/outputsfa
Ethernet IO-Link master with PROFINET S2 redundancyfa
Ethernet IO-Link module with 8 inputs/outputsfa
EtherNet/IP IO-Link master with 8 inputs/outputs, DIN rail, screw terminalfa
EtherNet/IP IO-Link master with 8 inputs/outputs, DIN rail, push-in connectorsfa
PROFINET IO IO-Link master with 8 inputs/outputs, DIN rail, screw terminalfa
PROFINET IO IO-Link master with 8 inputs/outputs, DIN rail, push-in terminalsfa
IO-Link master, supply via USB port or separate power supply, LED indicators, M12 plug for sensor connectionfa
RFID Transponderfa
RFID Transponderfa
RFID Transponderfa
RFID Transponderfa
Tag for standard applicationsfa
Tag for paint shop applicationsfa
Tag for autoclave applicationsfa
IIoT Starter Kit

Connect your factory floor sensors to the cloud and start your digital transformation with the new IIoT starter kits.