Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
Datasheet excerpt: Technical data of
RLK39-54/31/40a/116
Product Description |
Retroreflective sensor for standard applications, polarization filter, detection range 7 m, red light, sensitivity adjuster, light/dark on, relay contact output, terminal compartment |
General specifications |
Effective detection range | 0 ... 5 m |
Reflector distance | 0.1 ... 5 m |
Threshold detection range | 6 m |
Reference target | H50 reflector |
Light source | LED red |
Light type | modulated visible red light |
Polarization filter | yes |
Ambient light limit | IEC / EN 60947-5-2 , 10000 Lux |
Functional safety related parameters |
MTTFd | 803 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means |
Function indicator | LED yellow: switching state LED red: pre-fault indication |
Control elements | Sensing range adjuster, light-on/dark-on changeover switch |
Electrical specifications |
Operating voltage | 12 ... 240 V DC 24 ... 240 V AC (50 ... 60 Hz) |
Ripple | 10 % |
No-load supply current | ≤ 50 mA |
Protection class | II, rated voltage ≤ 250 V AC with pollution degree 1-2 according to IEC 60664-1 Caution! The protection class 2 is only valid when the terminal compartment is closed. output circuit has basic insulation to control circuit according to IEC/EN 61140 |
Power consumption | ≤ 3 VA |
Time delay before availability | ≤ 300 ms |
Output |
Switching type | light/dark on |
Signal output | 1 relay output |
Switching voltage | max. 240 V AC ; 150 V DC |
Switching current | max. 3 A |
Switching power | DC: max. 90 W AC: max. 750 VA |
Switching frequency | ≤ 25 Hz |
Response time | ≤ 20 ms |
Conformity |
Product standard | EN 60947-5-2 |
Approvals and certificates |
CCC approval | Certified by China Compulsory Certification (CCC) |
Approvals | CE |
Ambient conditions |
Ambient temperature | -25 ... 55 °C (-13 ... 131 °F) |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) |
Mechanical specifications |
Degree of protection | IP54 |
Connection | terminal compartment PG9 , ≤ 0.75 mm2 |
Material | |
| Housing | PBT |
| Optical face | PMMA |
Mass | approx. 110 g |
Dimensions | |
| Height | 64 mm |
| Width | 25 mm |
| Depth | 75 mm |
General information |
Scope of delivery | Mounting aid , Reflector |
Classifications
System | Classcode |
ECLASS 13.0 | 27270902 |
ECLASS 12.0 | 27270902 |
ECLASS 11.0 | 27270902 |
ECLASS 10.0.1 | 27270902 |
ECLASS 9.0 | 27270902 |
ECLASS 8.0 | 27270902 |
ECLASS 5.1 | 27270902 |
ETIM 9.0 | EC002717 |
ETIM 8.0 | EC002717 |
ETIM 7.0 | EC002717 |
ETIM 6.0 | EC002717 |
ETIM 5.0 | EC002717 |
UNSPSC 12.1 | 39121528 |
Details:
RLK39-54/31/40a/116
Product Documentation:
RLK39-54/31/40a/116
Design / Simulation:
RLK39-54/31/40a/116
Approvals:
RLK39-54/31/40a/116
Associated Products:
RLK39-54/31/40a/116
Accessories |
|
|
|
Mounting bracket for RL39 series Sensorsfa |
|