Serviceline Industrial Sensors
Serviceline Explosion Protection

Ultrasonic sensor UB2000-30GM-H3-Y48481

UB2000-30GM-H3-Y48481
  • Separate evaluation
  • Direct detection mode

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  UB2000-30GM-H3-Y48481

Product Description
Single head system
General specifications
Sensing range200 ... 2000 mm
Dead band0 ... 200 mm
Standard target plate100 mm x 100 mm
Transducer frequencyapprox. 175 kHz
Electrical specifications
Operating voltage10 ... 30 V DC , ripple 10 %SS
No-load supply current≤ 30 mA
Input
Input type1 pulse input for transmitter pulse, activation through open collector npn
< 1 V: emitter active, > 4 V: emitter inactive
Pulse length20 ... 200 µs
Pause length≥ 50 x pulse length
Output
Output type1 pulse output for echo propagation time, high-active, short-circuit proof
Signal level1-level: ≥ UB - 3 V ; ≤ 10 mA
level 0: ≤ 1 V; ≤ 0,1 mA
Temperature influencethe echo propagation time: 0.17 % / K
Compliance with standards and directives
Standard conformity
StandardsEN IEC 60947-5-2:2020
IEC 60947-5-2:2019
Approvals and certificates
UL approvalcULus Listed, General Purpose
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Degree of protectionIP65
Connection2 m PVC cable 0.75 mm2
Material
Housingnickel plated brass; plastic components: PBT
Transducerepoxy resin/hollow glass sphere mixture; polyurethane foam
Mass300 g
Dimensions
Length93 mm
Diameter30 mm

Classifications

SystemClasscode
ECLASS 13.027272803
ECLASS 12.027272803
ECLASS 11.027272803
ECLASS 10.0.127272803
ECLASS 9.027272803
ECLASS 8.027272803
ECLASS 5.127272803
ETIM 9.0EC001849
ETIM 8.0EC001849
ETIM 7.0EC001849
ETIM 6.0EC001849
ETIM 5.0EC001847
UNSPSC 12.141111960

Details: UB2000-30GM-H3-Y48481

Informative Literature: UB2000-30GM-H3-Y48481

Language Selection:
LiteratureLanguageFile TypeFile Size
/doct/tdoct9470__eng.pdfENGPDF452 KB
Application Report - Rugged Collision Protection for Cleaning RobotsENGPDF313 KB

Product Documentation: UB2000-30GM-H3-Y48481

Language Selection:
Brief InstructionsLanguageFile TypeFile Size
Instruction leaflet / BeipackzettelALLPDF586 KB
Safety and Security Documentation
Instruction manualENGPDF150 KB

Design / Simulation: UB2000-30GM-H3-Y48481

Language Selection:
CADLanguageFile TypeFile Size
CAD 3-D / CAD 3-DALLSTP28 KB
CAD Portal / CAD PortalALLLINK---

Approvals: UB2000-30GM-H3-Y48481

Language Selection:
CertificatesCertificate No.LanguageFile TypeFile Size
Canada USA UL Ordinary LocationUL-US-2140156-4 / UL-CA-2133660-4ALLPDF284 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-7420ALLPDF108 KB
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F)DOC-7421ALLPDF107 KB

Associated Products: UB2000-30GM-H3-Y48481

Accessories

Mounting flange, 30 mmfa

Universal mounting bracket for cylindrical sensors with a diameter of 5 ... 30 mmfa
Plastic mounting adapter, 30 mmfa
Ultrasonic -deflector, Universal mounting possibilities, 90° sound deflection for difficult installation circumstances, Focussing effectfa
Ultrasonic -deflector, Clamp mounting, 90° sound deflection for difficult installation circumstances, Universal Orientationfa
Plastic nuts with centering ring for the vibration-free mounting of cylindrical sensors, For insulated mountingfa
USi-safety Sensor System

The USi-safety ultrasonic sensor system is breaking new ground for safety applications—whether in challenging, dusty environments or in outdoor areas.

Pepperl+Fuchs offers you various downloadable documents containing knowledge on ultrasonic sensors.