Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
Datasheet excerpt: Technical data of
UC10000-F260-UE8R2
Product Description |
Single head system |
General specifications |
Sensing range | 800 ... 10000 mm |
Adjustment range | 800 ... 10000 mm |
Dead band | 0 ... 800 mm |
Standard target plate | 100 mm x 100 mm |
Transducer frequency | approx. 60 kHz |
Nominal ratings |
Time delay before availability | 280 ms |
Limit data |
Permissible cable length | max. 300 m |
Indicators/operating means |
LED yellow | solid: switching state switch output flashing: misadjustment |
Electrical specifications |
Rated operating voltage | 24 V DC |
Operating voltage | 15 ... 30 V (including ripple) In supply voltage interval 15 ... 20 V sensitivity reduced to 20% ... 0% |
Ripple | ≤ 10 % |
No-load supply current | ≤ 75 mA |
Input/Output |
Input/output type | 1 synchronization connection, bidirectional |
| 0 Level | ≤ 3 V |
| 1 Level | 15 ... 30 V |
| Input impedance | typ. 0.9 kΩ |
| Number of sensors | max. 10 |
Switching output |
Output type | 2 switch outputs PNP, NO |
Repeat accuracy | ± 15 mm |
Operating current | 300 mA , short-circuit/overload protected |
Voltage drop | ≤ 3 V |
Switch-on delay | 800 ms |
Analog output |
Output type | 1 voltage output: 0 ... 10 V rising ramp |
Default setting | 800 ... 10000 mm |
Linearity error | ≤ 1.5 % |
Load resistor | > 2 kΩ |
Compliance with standards and directives |
Standard conformity | |
| Standards | EN 60947-5-2:2007+A1:2012 IEC 60947-5-2:2007 + A1:2012 EN 60947-5-7:2003 IEC 60947-5-7:2003 |
Approvals and certificates |
UL approval | cULus Listed, General Purpose |
CSA approval | cCSAus Listed, General Purpose |
Ambient conditions |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Shock resistance | 30 g , 11 ms period |
Vibration resistance | 10 ... 55 Hz , Amplitude ± 1 mm |
Mechanical specifications |
Connection type | screw terminals , PG 13.5 cable gland |
Degree of protection | IP65 |
Material | |
| Housing | UP 1225 SF/R8 |
| Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam |
Installation position | any position |
Mass | 1800 g |
Dimensions | |
| Depth | 112 mm |
| Diameter | 160 mm |
Classifications
System | Classcode |
ECLASS 13.0 | 27272803 |
ECLASS 12.0 | 27272803 |
ECLASS 11.0 | 27272803 |
ECLASS 10.0.1 | 27272803 |
ECLASS 9.0 | 27272803 |
ECLASS 8.0 | 27272803 |
ECLASS 5.1 | 27272803 |
ETIM 9.0 | EC001849 |
ETIM 8.0 | EC001849 |
ETIM 7.0 | EC001849 |
ETIM 6.0 | EC001849 |
ETIM 5.0 | EC001849 |
UNSPSC 12.1 | 41111960 |
Details:
UC10000-F260-UE8R2
Product Documentation:
UC10000-F260-UE8R2
Design / Simulation:
UC10000-F260-UE8R2
Approvals:
UC10000-F260-UE8R2
Associated Products:
UC10000-F260-UE8R2
Accessories |
|
|
|
Male cordset single-ended M12 straight A-coded, 5-pin, PVC cable greyfa |
|