Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
Product Description |
---|
AS-Interface power supply, data decoupling, 4 A |
General specifications | ||
---|---|---|
UL File Number | E223176 | |
MTBF | 100 a | |
Indicators/operating means | ||
Reset push-button switch | earth fault simulation/reset of earth fault display | |
LED EFD | earth fault display; LED red | |
LED AS-i ok | LED green: ON: AS-Interface voltage OK OFF: overload or no supply voltage |
|
Electrical specifications | ||
Fusing | T3A 15/250 V HBC (not accessible) | |
Rated operating voltage | 85 … 132 VAC 184 … 264 VAC 240 … 300 VDC |
|
Rated operating current | 2.7 A at 115 VAC 1.3 A at 230 VAC |
|
Supply frequency | 47 ... 63 Hz (alternatively, DC possible) | |
Efficiency | typ. 90 % (230 VAC, 4 A) | |
Galvanic isolation | SELV/PELV | |
Peak inrush current | < 3.7 A2s (120 VAC) < 4.6 A2s (132 VAC) < 2.5 A2s (230 VAC) < 3.3 A2s (264 VAC) |
|
Output | ||
Short-circuit protection/overload | > 4,2 A < 6.5 A |
|
Current limit | starts at > 4.2 A | |
Voltage | 30.5 VDC ±3 % fixed setting | |
Current | 4 A | |
Residual ripple | < 50 mVSS (500 kHz bandwidth, 50 Ω measurement, with resistive load) | |
Voltage limitation | limited to max. 55 V | |
Compliance with standards and directives | ||
Directive conformity | ||
EMC Directive 2004/108/EC | EN 55022:2006, EN 55011:2009 Class B EN 61000-6-3:2001 , EN 61204-3:2001 |
|
Standard conformity | ||
Noise immunity | EN 61000-6-2:2005 | |
Emitted interference | EN 61000-6-3:2007 EN 61000-3-2:2010 EN 61000-3-3:2009 |
|
Galvanic isolation | IEC 60364-4-41:2005 (PELV) IEC 60950:1999 (SELV) |
|
Degree of protection | IEC 60529:2001 | |
Pollution degree | EN 50178:1997 | |
Mech. capacity | EN 60068-2-6:2008 (Sinus) EN 60068-2-64:2009 (Random) |
|
Shock and impact resistance | EN 60068-2-27:1995 | |
Ambient conditions | ||
Ambient temperature | -10 ... 70 °C (14 ... 158 °F) note derating |
|
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Shock and impact resistance | 15g/6 ms 10g/11 ms |
|
Vibration resistance | Sine 2 - 17.8 Hz: ± 1.6 mm Sine 17.8 ... 500 Hz : 2 g Random 2 … 500 Hz: 0.5 m2 (s³) |
|
Pollution degree | 2 | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Protection class | 1 (IEC 60536); Protective conductor connection necessary | |
Connection | Connection terminals, max. conductor cross-section Flexible cable: 0.5 … 4 mm2 Rigid cable: 0.5 … 6 mm2 Stripping length 7 mm |
|
Mass | 650 g | |
Dimensions | ||
Height | 124 mm | |
Width | 73 mm | |
Length | 102 mm | |
Mounting | DIN mounting rail |
System | Classcode |
---|---|
ECLASS 13.0 | 27040301 |
ECLASS 12.0 | 27040301 |
ECLASS 11.0 | 27040301 |
ECLASS 10.0.1 | 27040301 |
ECLASS 9.0 | 27040301 |
ECLASS 8.0 | 27040301 |
ECLASS 5.1 | 27040301 |
ETIM 9.0 | EC002540 |
ETIM 8.0 | EC002540 |
ETIM 7.0 | EC002540 |
ETIM 6.0 | EC002540 |
ETIM 5.0 | EC002540 |
UNSPSC 12.1 | 39121004 |
The primary switched-mode power supply was designed for fieldbus applications that transfer energy and data together via a two-wire cable
(AS-Interface concept). It supplies a fully extended AS-Interface system with a maximum output current of 4.0 A. Due to the sinusoidal current consumption of the network, harmonics are avoided.
The power supply assumes the function of supplying power, data decoupling for the power source and balancing both output lines
(AS-Interface + and AS-Interface -) with respect to the machine ground (shielded connection). The transformer allows the use of unshielded load cables. The power supply is protected by an internal fuse that eliminates the need for additional device protection measures.
Ground fault monitor GF:
The switch output of the ground fault monitor evaluates any short circuits detected in the AS-Interface system. With the potential-free transistor output, the system can be shut down using the control program. The output is normally closed, but opens when a ground fault is detected. The "GF" LED also signals the presence of a ground fault. This output will close when the power supply is restarted or the reset button is pressed for (> 2 seconds). It is essential to connect the shield to PE or the machine ground to guarantee proper operation.
Checking the ground fault monitor:
Pressing the reset button briefly (< 2 seconds) simulates a ground fault in the device. Detection, evaluation and signaling of a ground fault and the switch output can be tested at suitable intervals. A ground fault generated in this way can be reset by pressing the reset button for (> 2 seconds).
Brief Instructions | Language | File Type | File Size |
---|---|---|---|
Instruction leaflet / Beipackzettel | ALL | 350 KB |
CAD | Language | File Type | File Size |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 2062 KB |
CAD Portal / CAD Portal | ALL | LINK | --- |
CAE | |||
CAE EPLAN Data Portal / CAE EPLAN Data Portal | ALL | LINK | --- |
CAE EPLAN macro EDZ / CAE EPLAN Makro EDZ | ALL | EDZ | 98 KB |
Certificates | Certificate No. | Language | File Type | File Size |
---|---|---|---|---|
US CA UL | E223176 | ALL | LINK | --- |
US CA UL | CoC E223176 RptRef E223176-20070416 | ALL | 444 KB | |
Worldwide AS-International Association AS-Interface | 95001 | ALL | 389 KB | |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-4815A | ALL | 164 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|