Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
Product Description |
---|
6000 series purge and pressurization system vent |
General specifications | ||
---|---|---|
Series | 6000 Series | |
System | Type X Purge ; Ex pxb Purge | |
Number of volume exchanges | 4 to 19 | |
Hazardous environment | gas, dust, gas and dust | |
Electrical specifications | ||
Connection | ||
Power | Intrinsically Safe back to 6000 control unit | |
Signal | BUS back to 6000 control unit | |
Connection | M12 connector, 4-pin | |
Indicators/settings | ||
LED indication | power: green vent number: yellow, on for second vent |
|
Pneumatic parameters | ||
Protective gas supply | instrument grade air or inert gas | |
Safe pressure | Gas: 0.25" wc (6.4 mm wc) (0.625 mbar) (62 Pa) Dust: 0.65" wc (16.5 mm wc) (1.6 mbar) (162 Pa) Gas and Dust: 0.65" wc (16.5 mm wc) (1.6 mbar) ( 162 Pa) |
|
Enclosure pressure | 0 ... 9.9" wc (25 mbar) (250 mm wc) | |
Max. enclosure pressure | 25" wc (62 mbar) (625 mm wc) | |
Purge flow rate | Maximum flow rate measurement for enclosure size (enclosure volume:flow rate): < 20 ft3 (0.57 m3): 5, 12 SCFM (141, 340 l/min), or dynamic 20 ... 30 ft3 (0.57 ... 0.85 m3): 5, 12, 20 SCFM (141, 340, 565 l/min), or dynamic > 30 ft3 (0.85 m3): 5, 12, 20, 30 SCFM (141, 340, 565, 850 l/min), or dynamic |
|
Purge flow and enclosure pressure rate | With EPV-6000-xx-01, EPV-6000-xx-02 141 l/min @ 3.7 mbar, (5 SCFM @ 1.5" wc) 340 l/min @ 5.0 mbar, (12 SCFM @ 2.0" wc) 565 l/min @ 6.7 mbar, (20 SCFM @ 2.7" wc) 850 l/min @ 10.2 mbar, (30 SCFM @ 4.1" wc) With EPV-6000-xx-03, EPV-6000-xx-04 141 l/min @ 5.2 mbar, (5 SCFM @ 2.1" wc) 340 l/min @ 6.5 mbar, (12 SCFM @ 2.6" wc) 565 l/min @ 10.2 mbar, (20 SCFM @ 4.1" wc) 850 l/min @ 13.2 mbar, (30 SCFM @ 5.3" wc) With EPV-6000-xx-05, 06 141.6 l/min @ 4.1 mbar, (5 SCFM @ 1.64" wc) 339.8 l/min @ 5.5 mbar, (12 SCFM @ 2.20" wc) 566.3 l/min @ 14.9 mbar, (20 SCFM @ 6.00" wc) |
|
Flow rate for leakage compensation | Depends on enclosure seal. With EPV-6000-xx-01, EPV-6000-xx-02 0.35 SCFM @ 0.25" wc (10.0 l/min @ 0.63 mbar) 1.0 SCFM @ 0.75" wc (28.0 l/min @ 1.9 mbar) With EPV-6000-xx-03, EPV-6000-xx-03 0.22 SCFM @ 0.25" wc (6.2 l/min @ 0.63 mbar) 0.58 SCFM @ 0.75" wc (16.4 l/min @ 1.9 mbar) With EPV-6000-xx-05, EPV-6000-xx-06 0.15 SCFM @ 0.25" wc (4.2 l/min @ 0.63 mbar) 0.35 SCFM @ 0.75" wc (10.0 l/min @ 1.9 mbar) |
|
Breaking pressure | EPV-6000-xx-01, EPV-6000-xx-02: 0.8" wc (2.0 mbar) EPV-6000-xx-03, EPV-6000-xx-04: 1.3" to 1.4" wc (3.2 to 3.5 mbar) EPV-6000-xx-05, EPV-6000-xx-06: 1.4" to 1.5" wc (3.5 to 3.8 mbar) |
|
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 EN 61000-6-2:2005 |
|
RoHS | ||
Directive 2011/65/EU (RoHS) | EN IEC 63000:2018 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Storage temperature | -30 ... 80 °C (-22 ... 176 °F) | |
Relative humidity | 5 ... 95 %, noncondensing | |
Vibration resistance | 5 ... 100 Hz , 1 g, 12 m/s2, all axes | |
Impact resistance | 30 g, 11 ms, all axes | |
Mechanical specifications | ||
Material | EPV-6000-AA-.... Cap: marine grade 5052 anodized aluminum, marine grade 6061T6 anodized aluminum EPV-6000-SS-.... Cap: 316L (UNS S31603) stainless steel; Body: marine grade 6061T6 anodized aluminum |
|
Spark arrestor | 304 (UNS S30400) stainless steel | |
Installation | - any orientation to enclosure - not gravity dependent - internal and external mounting possible |
|
Mass | approx. 1.4 kg (3.1 lb) | |
Dimensions | 127.5 x 146 x 82.5 mm (5.05 x 5.75 x 3.25 inch) | |
Height | 146 mm | |
Width | 127.5 mm | |
Depth | 82.5 mm | |
Mounting | 1 1/2" NPT knockout (50.8 mm (2") hole) with sealed nut |
|
Data for application in connection with hazardous areas | ||
EU-type examination certificate | DEMKO 15 ATEX 1622X | |
Marking | II 2 G Ex ib [pxb Gb] IIC T4 Gb II 2 D Ex ib [pxb Db] IIIC T135 °C Db -20 °C ≤ Ta ≤ 60 °C |
|
Directive conformity | ||
Directive 2014/34/EU | EN IEC 60079-0:2018 , EN 60079-2:2014 , EN 60079-11:2012 | |
International approvals | ||
UL approval | cULus Class I, Division 1, Groups A, B, C, D IP66/Type 4X Class I, Zone 1, Groups IIC, T4 Class II, Division 1, Groups E, F, G Class II, Zone 21, Group IIIC T135 °C -20 °C ≤ TA ≤ 60 °C Ex i intrinsically safe |
|
IECEx approval | Ex ib [pxb Gb] IIC T4 Gb Ex ib [pxb Db] IIIC T135 °C Db -20 °C ≤ Ta ≤ 60 °C IECEx UL 15.0147X |
|
General information | ||
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
System | Classcode |
---|---|
ECLASS 13.0 | 27180591 |
ECLASS 12.0 | 27180591 |
ECLASS 11.0 | 27180591 |
ECLASS 10.0.1 | 27292190 |
ECLASS 9.0 | 27292190 |
ECLASS 8.0 | 27292190 |
ECLASS 5.1 | 40050501 |
ETIM 9.0 | EC000243 |
ETIM 8.0 | EC000243 |
ETIM 7.0 | EC000243 |
ETIM 6.0 | EC000243 |
ETIM 5.0 | EC000243 |
UNSPSC 12.1 | 39121303 |
The EPV-6000 vent exhausts excess pressure from the enclosure and measures flow and pressure during operation. The 6000 series vent has a pressure transducer and thermal flow sensor that is connected to the 6000 EPCU. It is intrinsically safe through the galvanic isolation barrier within the 6000 EPCU.
Because measurement of the flow is always at the exhaust of the pressurized enclosure, the vent is located on the enclosure(s) such that it is venting to the atmosphere.The EPV-6000 vent can be mounted vertically or horizontally and is not gravity dependent.
The EPV-6000 vent can be mounted externall or internally to the enclosure. When mounting internally, only the vent cap is exposed to the outside atmosphere.
Safety and Security Documentation | Language | File Type | File Size |
---|---|---|---|
Instruction manual | ENG | 174 KB | |
Manuals | |||
Manual | ENG | 10850 KB |
CAD | Language | File Type | File Size |
---|---|---|---|
3D drawing for EPV-6000 and EPV-6500 Vent / 3-D-Modell für EPV-6000 und EPV-6500 Druckwächter | ALL | STP | 7814 KB |
CAD Portal / CAD Portal | ALL | LINK | --- |
Certificates | Certificate No. | Language | File Type | File Size |
---|---|---|---|---|
ATEX Certificate | DEMKO 15 ATEX 1622X Rev. 1 | ALL | 256 KB | |
China SITIIAS CCC Ex Certificate | 2020322304002499 (Katy, TX USA) | ALL | 1041 KB | |
IECEx Certificate of Conformity | IECEx UL 15.0147X | ALL | LINK | --- |
UK-Type Examination Certificate | UL21UKEX2016X | ALL | 231 KB | |
UL Hazardous Location | E184741 (RFPW, RFPW7 , RFPZ7) | ALL | 741 KB | |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-B067C | ALL | 145 KB | |
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F) | DOC-B0G1A | ALL | 157 KB |
Accessory of | ||||||
---|---|---|---|---|---|---|
|