Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
Product Description |
---|
KE1-Safety module for the control cabinet 2 safety-related inputs and 2 conventional electronic outputs |
General specifications | ||
---|---|---|
Node type | Safety-Slave | |
AS-Interface specification | V3.0 | |
Required gateway specification | ≥ V2.1 | |
UL File Number | E223772 | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 3 | |
Performance level (PL) | PL e | |
Category | Cat. 4 | |
Mission Time (TM) | 20 a | |
PFHd | 2.83 E-9 | |
PFD | 8 E-7 | |
Indicators/operating means | ||
LED FAULT | Fault indication: red LED Red: communication error or address is 0 Red flashing: peripheral fault |
|
LED AS-i | AS-Interface voltage; LED green | |
LED AUX | auxiliary voltage UAUX ; LED green | |
LED IN | switching state (input); 2 LED yellow | |
LED OUT | Switching state (output); 2 LED yellow | |
Electrical specifications | ||
Auxiliary voltage (output) | 24 V (20 VDC… 30 VDC) | |
Rated operating voltage | 22 ... 31.6 V | |
Rated operating current | ≤ 70 mA | |
Protection class | III | |
Current consumption | max. 35 mA (AS-Interface) max. 4 A (AUX) |
|
Surge protection | UAUX, Ue: overvoltage category II, safe isolated power supplies (PELV) | |
Input | ||
Number/Type | 2 inputs for a 2-channel active optoelectronic protective devices (AOPD) for safeguarding positions and areas of danger up to PL e in accordance with EN / ISO 13849-1 | |
Supply | from AUX | |
Voltage | 20 ... 30 V DC pulsed | |
Current loading capacity | 1800 mA for power supply of external sensors from AUX | |
Switching point | Vin> 11 V for high level, input current ≥ 2.5 mA at 15 V | |
Output | ||
Number/Type | 2 conventional electronic outputs, short-circuit proof | |
Supply | from AUX | |
Current | 1 A per output note derating |
|
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 62026-2:2013 EN 61326-3-1:2008 | |
Standard conformity | ||
Electromagnetic compatibility | EN 61000-6-2:2005, EN 61000-6-3:2007/A1:2011 EN 61131-2:2007 | |
Degree of protection | EN 60529:2000 | |
Fieldbus standard | EN 62026-2:2013 | |
AS-Interface | EN 62026-2:2013 | |
Functional safety | EN ISO 13849-1:2008 up to PL e EN 62061:2005/A1:2013 up to SIL 3 | |
Programming instructions | ||
Profile | S-7.B.1. | |
IO code | 7 | |
ID code | B | |
ID1 code | F | |
ID2 code | 1 | |
Data bits (function via AS-Interface) | ||
D0 | ||
D1 | ||
D2 | ||
D3 | ||
Parameter bits (programmable via AS-i) | function | |
P0 | Communication monitoring P0 = 0 monitoring = off, the outputs maintain the status if communication fails P0 = 1 monitoring = on, i.e. if communication fails, the outputs are deenergised (default settings) |
|
P1 | not used | |
P2 | not used | |
P3 | not used | |
Ambient conditions | ||
Ambient temperature | 0 ... 55 °C (32 ... 131 °F) , no moisture condensation | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Altitude | ≤ 2000 m above MSL | |
Shock and impact resistance | ≤ 15 g at T ≤ 11 ms, 10 ... 55 Hz, 0,5 mm amplitude | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | removable terminals, terminal connection 0.2 ... 2.5 mm2 | |
Material | ||
Housing | PA 66-FR | |
Mass | 60 g | |
Dimensions | ||
Height | 99.6 mm | |
Width | 22.5 mm | |
Length | 48.5 mm | |
Mounting | DIN mounting rail | |
Tightening torque of clamping screws | 0.5 Nm ... 0.6 Nm |
System | Classcode |
---|---|
ECLASS 13.0 | 27272603 |
ECLASS 12.0 | 27242604 |
ECLASS 11.0 | 27242604 |
ECLASS 10.0.1 | 27242604 |
ECLASS 9.0 | 27242604 |
ECLASS 8.0 | 27242604 |
ECLASS 5.1 | 27242604 |
ETIM 9.0 | EC001599 |
ETIM 8.0 | EC001599 |
ETIM 7.0 | EC001599 |
ETIM 6.0 | EC001599 |
ETIM 5.0 | EC001599 |
UNSPSC 12.1 | 39121535 |
The VAA-2E2A-KE1-SE is an AS-Interface safety module with two safety-related inputs and two outputs. A self-testing electronic protective system can be connected to the two safety-related inputs. The outputs are conventional electronic outputs that can be loaded to a total of 3 A (max. 1 A per output).
The housing is only 22.5 mm wide and 48.5 mm tall and takes up little space in the switch cabinet. A snap-on function mounts the module onto the 35 mm mounting strip in line with EN 50022. An addressing socket is integrated in the module.
The connection is made via plug-in terminals. A four-way (black) terminal block is used for the inputs. The AS-Interface is connected via a two-way (yellow) terminal block.
Each channel has an LED mounted on the top side of the module to display the current switching status. There is an LED for monitoring AS-Interface communication and for displaying that the module has the address 0. In the event of communication faults, the outputs are disconnected from the power supply (only for P0 = 1).
If a noncontact protective system is connected, the module can be upgraded to performance level e in accordance with EN ISO 13849-1 if wired appropriately. As per the approval in accordance with EN 62061, a Safety Integrity Level of up to SIL 3 can be reached.
Brief Instructions | Language | File Type | File Size |
---|---|---|---|
Instruction manual VAA-2E2A-KE1-SE / Betriebsanleitung VAA-2E2A-KE1-SE | ALL | 434 KB | |
Mounting Instruction VAA-2E2A-KE1-SE / Montageanleitung VAA-2E2A-KE1-SE | ALL | 1192 KB | |
Manuals | |||
Manual VAA-2E2A-KE1-SE | ENG | 1595 KB |
CAD | Language | File Type | File Size |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 1743 KB |
CAD Portal / CAD Portal | ALL | LINK | --- |
CAE | |||
CAE EPLAN Data Portal / CAE EPLAN Data Portal | ALL | LINK | --- |
CAE EPLAN macro EDZ / CAE EPLAN Makro EDZ | ALL | EDZ | 43 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|