Serviceline Industrial Sensors
Serviceline Explosion Protection

Ex pz digital valve 7500-MAN-BK-**-*

7500-MAN-BK-**-*
  • Optional digital valve
  • Compensates for pressure fluctuations
  • 230 VAC, 115 VAC, or 24 VDC
  • Contacts are powered by the 7500 control unit

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  7500-MAN-BK-**-*

General specifications
Series7500
Hazardous environmentgas or dust
Supply
Rated voltage230 VAC ±10%
115 VAC ± 10%
24 VDC ±10%
Power consumption230 VAC @ 1.8 W
115 VAC @ 9 W
24 VDC @ 9 W
Pneumatic parameters
Protective gas supplyinstrument grade air or inert gas
Pressure requirementT6 version: 0.2 bar (2.9 psi) to 4.0 bar (58 psi)
T4 version: 0.2 bar (2.9 psi) to 16 bar (232 psi)
Purge flow rateKv value water 3.8 m3/h
ConnectionsG1/2 (13 mm)
Ambient conditions
Ambient temperature-40 ... 55 °C (-40 ... 131 °F)
Storage temperature-40 ... 80 °C (-40 ... 176 °F)
Mechanical specifications
Connection typeInlet/outlet size: G 1/2 (13 mm)
Jet size: 3.0 mm and 4.5 mm size (included)


Degree of protectionIP65
MaterialBody: brass
Valve (intenal): brass
Seal: NBR
Data for application in connection with hazardous areas
EU-type examination certificate
MarkingEx-Hexagon II 2 G Ex mb IIC T4/T6 Gb
Ex-Hexagon II 2 D Ex mb IIIC T130 °C / T80 °C Db
Protection by encapsulation

EPS 18 ATEX 1232 X
CertificateCCC approvals
MarkingEx mb IIC T4/T5/T6 Gb
Ex mbD 21 T80°C/T95°C/T130°C
Directive conformity
Directive 2014/34/EUEN IEC 60079-0:2018, EN IEC 60079-7:2015/A1:2018, EN 60079-18:2015/A1:2017, EN 60079-31:2014
International approvals
IECEx approvalIECEx EPS 18.0110X
Ex mb IIC T4/T6 Gb
Ex mb IIIC T130 °C/T80 °C Db

Classifications

SystemClasscode
ECLASS 13.027180591
ECLASS 12.027180591
ECLASS 11.027180591
ECLASS 10.0.127291390
ECLASS 9.027291390
ECLASS 8.027291390
ECLASS 5.140050501
ETIM 9.0EC000243
ETIM 8.0EC000243
ETIM 7.0EC000243
ETIM 6.0EC000243
ETIM 5.0EC000243
UNSPSC 12.139121303

Details: 7500-MAN-BK-**-*

Function

The 7500 series Type Z/Ex pz purge and pressurization system allows general purpose equipment to be mounted in enclosures and operate safely in Division 2, Zone 2, or Zone 22 hazardous areas. The 7500 digital valve is used to pressurize the enclosure by adjusting an internal needle valve for pressure; purging of the enclosure is accomplished via a two-way valve. The 7500 control unit is set up to work with and power up the 7500 digital valve. The digital valve is Ex rated for hazardous areas.

The 7500-MAN-BK-**-* digital valve works with the 7500 control unit and is ATEX and CCC certified for use in Zone 2 or Zone 22 applications.

Approvals: 7500-MAN-BK-**-*

Language Selection:
CertificatesCertificate No.LanguageFile TypeFile Size
/cert/certb150.pdfEPS 18 ATEX 1232 XALLPDF1906 KB
China SITIIAS CCC Ex Certificate2021322307003982 (Katy, TX USA)ALLPDF2905 KB
IECEx Certificate of ConformityIECEx EPS 18.0110XALLLINK---
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-B0G9ALLPDF238 KB
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-B0H3ALLPDF48 KB
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F)DOC-B0H1ALLPDF163 KB

Get to know the smartest way to ensure hazardous location protection and configure your individual purge and pressurization system!

This purge and pressurization system takes hazardous area protection to a new level of innovation and confidence. Designed for Class I or II/Div. 2 and Zone 2/22 locations, it provides unique features in an extremely small housing …