Serviceline Industrial Sensors
Serviceline Explosion Protection

6500 digital valve 6500-MAN-DV

6500-MAN-DV
  • Suitable for Zone 1&21 operation, ATEX/IECE certification
  • Intrinsically safe when connected to the 6000 or 6500 control unit
  • Manifold combines the digital valve for purging and the needle valve for pressurization in one housing
  • Suitable for steel or plastic tubing
  • Mounting hardware, pneumatic fittings and tubing included

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  6500-MAN-DV

Product Description
Type Ex px purge and pressurization system
General specifications
Operating modeautomatic purging + pressurization
Hazardous environmentgas or dust
Supply
Rated powerIntrinsically safe supply from the 6500 control unit
Pneumatic parameters
Protective gas supplyinstrument grade air or inert gas
Pressure requirement1.4 (20 psig) to 8.3 bar (120 psig)
Safe pressureGas: 0.35'' wc (8,88 mm wc) (0.88 mbar/ 88 pa)
Dust: 0.35'' wc (8,88 mm wc) (0.88 mbar/ 88 pa)
Gas+Dust: 0.35'' wc (8,88 mm wc) (0.88 mbar/ 88 pa)
Purge flow rateDigital valve : Cv (flow coefficient) = 1.4
needle valve : Cv (flow coefficient) = 0.24
ConnectionsInlet and outlet of valves
3/8"NPT, double ferrule 10mm compression fittings (included)
Ambient conditions
Ambient temperature-28 ... 65 °C (-18.4 ... 149 °F)
Storage temperature-28 ... 65 °C (-18.4 ... 149 °F)
Mechanical specifications
Connection type10 mm stainless steel ferrule tube fittings
Cable glandI.S. connection: Hirschmann DIN 43650-A connector
Degree of protectionIP65 (DIN connector)
MaterialHousing: anodized aluminum
3/8" compression fittings: 316L stainless steel
Pressure ports: 10 mm
Bulkhead fitting: 10 mm fitting, 316L stainless steel
Mounting bolts: 1/4 - 20, 316 stainless steel
Sealing washers: silicone rubber
Input/Output ports: 10 mm tube compression fittings
Mass850 g (1,87 lbs)
Dimensions153 x 105 x 56 mm (6.0'' x 4.2'' x 2.2'')

Classifications

SystemClasscode
ECLASS 13.027180591
ECLASS 12.027180591
ECLASS 11.027180591
ECLASS 10.0.127291390
ECLASS 9.027291390
ECLASS 8.027291390
ECLASS 5.140050501
ETIM 9.0EC000243
ETIM 8.0EC000243
ETIM 7.0EC000243
ETIM 6.0EC000243
ETIM 5.0EC000243
UNSPSC 12.139121303

Details: 6500-MAN-DV

Function

The 6500-MAN-DV-01 combines a digital valve for purging and a needle valve for pressurization in to one manifold design. When the valve is energized, the digital valve opens and allows for a high flow rate of protective gas into the enclosure. When the valve is de-energized, the flow through the internal needle valve is adjustable by a flathead screw driver through the needle stem on the manifold. The digital valve is used for purging, excess leakage compensation (pressure as input), and temperature control through user selected functions in the 6000/6500 control unit.

Mounting hardware includes 10 mm tube compression fittings mounted on the manifold for input and output flow, 10mm tube compression bulkhead fitting for getting flow into the enclosure, and seal washers with bolts to mount the manifold to the enclosure. Also included is a 1 meter of 3/8" polytubing with 10 mm poly tube stiffener inserts which allows the connection of plastic tubing to compression fittings without collapsing the tubing.

Informative Literature: 6500-MAN-DV

Language Selection:
LiteratureLanguageFile TypeFile Size
Application Report - Hydrogen Analysis with Reliable Explosion ProtectionENGPDF253 KB
Application Report - Label Printer Solution for Zone 1/21 and Zone 2/22 ApplicationsENGPDF135 KB

Product Documentation: 6500-MAN-DV

Language Selection:
Safety and Security DocumentationLanguageFile TypeFile Size
Instruction manualENGPDF168 KB

Approvals: 6500-MAN-DV

Language Selection:
CertificatesCertificate No.LanguageFile TypeFile Size
ATEX CertificatePTB 02 ATEX 2154ALLPDF3145 KB
China SITIIAS CCC Ex Certificate2021322307003982 (Katy, TX USA)ALLPDF2905 KB
IECEx Certificate of ConformityIECEx PTB 08.0023ALLLINK---
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-B0G8ALLPDF229 KB
EU Declaration of Conformity (External) / EU-Konformitätserklärung (extern)DOC-B0D6AALLPDF54 KB
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F)DOC-B0H0ALLPDF155 KB

Get to know the smartest way to ensure hazardous location protection and configure your individual purge and pressurization system!