Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Download the complete datasheet as a PDF:
Product Description |
---|
Direct Monitor - System with Enclosure |
General specifications | ||
---|---|---|
Type | Direct Monitor | |
Supply | ||
Power consumption | ||
AC | 115/230 V a.c. (100 ... 240 V a.c.), max. 0.4 A , max. 40 W For connections designation refer to the Power Supply PS1000-A6-24.5 manual. |
|
DC | 20 ... 28 V d.c. / 1.5 A (SELV/PELV or class 2) For connections designation refer to the VisuNet FLX Panel Mount manual. |
|
Indicators/operating means | ||
Display | ||
Type | Liquid Crystal Display (LCD) with LED backlight | |
Screen diagonal | 54.61 cm (21,5 '') | |
Resolution | 1920 x 1080 pixels (Full HD) Aspect ratio 16:9 |
|
Color depth | 24 bit (16.7 M) color | |
Contrast | 22FC: 5000:1 | |
Brightness | 22FC: 300 cd/m2 | |
Reading angle | 22FC: 170 ° horizontal, 160 ° vertical | |
Life span | 22FC: back lamp life: 50.000 hrs typical half life, at 25 °C (77 °F) | |
Input devices | ||
Touch screen | 10-finger multi-touch, glove-friendly Configurable display options: 22FC: Capacitive touch, optical bonding |
|
Keyboard | Optional: Foil keyboard with different pointing device options available (see EXTA4 datasheet) | |
Interface | ||
Interface type | 1x Power input w/ 3 pin terminal block 1x HDMI 1x DVI-I 1x VGA 1x USB 1x 3,5mm audio jack (Line-out) 1x OSD Menu w/ power button |
|
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (ind. Locations) EN 61000-6-4:2007+A1:2011 |
|
Explosion protection | ||
Directive 2014/34/EU | EN IEC 60079-0:2018 EN IEC 60079-7:2015/A1:2018 EN 60079-31:2014 |
|
RoHS | ||
Directive 2011/65/EU (RoHS) | EN IEC 63000:2018 | |
Ambient conditions | ||
Operating temperature | -20 ... 50 °C (-4 ... 122 °F) |
|
Storage temperature | -20 ... 65 °C (-4 ... 149 °F) | |
Relative humidity | max. relative humidity 93% at 50°C (non-condensing) according to EN60068-2-78 | |
Climatic conditions | Passive cooling, no rotating parts. | |
Altitude | Operating altitude max. 2000 m | |
Shock resistance | 18 shocks 15 g, 11 ms all axis, IEC 60068-2-27 | |
Vibration resistance | 10 ... 150 Hz, +/- 0.075 mm, 1g, 10 cycles per axis according to EN60068-2-6 | |
Mechanical specifications | ||
Degree of protection | IP66/Type 4X | |
Material | Housing: Powder-coated marine-grade aluminum alloy (EN AW-5754) | |
Installation | System with enclosure | |
Mass | Approx. 11.4 kg Approx. 13.4 kg with AC power supply with top sunshield: + Approx. 1.6 kg with top and side sunshield: + Approx. 3 kg |
|
Dimensions | 577 mm x 466 mm x 233 mm | |
International approvals | ||
UL approval | ||
Approved for | UL OrdLoc UL approval E223772 UL61010-1 Ed.3 UL 61010-2-201 Ed2 CAN/CSA C22.2 No 61010-1-12 CAN/CSA C22.2 No 61010-2-201 UL HazLoc Mounting in CL I, DIV 2, GP A-D, T4 CL II, DIV 2, GP F, G, T4 CL III Mounting in CL I, ZN 2, IIC, T4 CL II, ZN 22, IIIB, T85°C CL III, ZN 22, IIIA, T85°C |
|
ATEX approval | ||
ATEX certificate | UL 22 ATEX 2481X | |
ATEX marking | II 3 G Ex ec [ic] IIC T4 Gc II 3 D Ex tc IIIC T85°C Dc |
|
IECEx approval | ||
IECEx certificate | IECEx ULD 22.0019X | |
IECEx marking | Ex ec IIC T4 Gc Ex tc IIIC T85°C Dc |
|
IECEx standard | IEC 60079-0:2017 Ed 7.0 IEC 60079-7:2017 Ed 5.1 IEC 60079-31:2013 Ed. 2 |
System | Classcode |
---|---|
ECLASS 13.0 | 27330190 |
ECLASS 12.0 | 27330190 |
ECLASS 11.0 | 27330190 |
ECLASS 10.0.1 | 27330190 |
ECLASS 9.0 | 27330190 |
ECLASS 8.0 | 27330190 |
ECLASS 5.1 | 27242301 |
ETIM 9.0 | EC002504 |
ETIM 8.0 | EC002504 |
ETIM 7.0 | EC002504 |
ETIM 6.0 | EC002504 |
ETIM 5.0 | EC001412 |
UNSPSC 12.1 | 39121106 |
The VisuNet FLX Systems are designed for Zone 2/22 (Div. 2) and non-Ex applications.
The VisuNet FLX's rugged aluminum enclosure provides optimized thermal conductivity for improved heat transfer and temperature management. The high corrosion resistance of the housing makes the VisuNet FLX platform attractive for industries with high ambient temperatures, such as manufacturing, oil & gas, water & wastewater, and loading & filling. Industries such as life science, (petro)chemical and pharmaceutical also benefit from the advantages of the aluminum variant of the VisuNet FLX.
The various mounting and configuration options provide maximum application flexibility. Thanks to its fully modular design, the new platform, which is tailored to the needs of the (petro)chemical and pharmaceutical industries, the HMIs can be configured to fit exactly and allow for easy and quick adjustments in the field. The modern, compact design requires less installation space. The low weight allows for cost-effective and easy installation.
Safety and Security Documentation | Language | File Type | File Size |
---|---|---|---|
Instruction manual | ENG | 249 KB | |
Manuals | |||
Manual | ENG | 32436 KB |
Certificates | Certificate No. | Language | File Type | File Size |
---|---|---|---|---|
ATEX | UL 22 ATEX 2481X | ALL | 592 KB | |
IECEx Certificate of Conformity | IECEx ULD 22.0019X | ALL | LINK | --- |
UL Hazardous Location | E492874 | ALL | 194 KB | |
UL Ordinary Location | E223772 | ALL | 194 KB | |
Declaration of Conformity | ||||
EU-Declaration of Conformity VisuNet FLX System DC (Non-Ex) / EU-Konformitätserkärung VisuNet FLX System DC (Non-Ex) | DOC-4983B | ALL | 211 KB | |
EU-Declaration of conformity ATEX RM-320S-L / PC-320S-L / DM-320S-L / EU-Konformitätserklärung ATEX RM-320S-L / PC-320S-L / DM-320S-L | DOC-5836C | ALL | 215 KB | |
EU-Declaration of conformity VisuNet FLX System AC (Non-Ex) / EU-Konformitätserklärung VisuNet FLX System AC (Non-Ex) | DOC-5300B | ALL | 211 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|