PS1000-D2-24.20.RM Redundancy Module
Key Benefits at a Glance
- 24 V DC to 28 V DC input
- 2 inputs with 1 output
- Output 24 V DC, 20 A
- Housing width 32 mm
- Built-in decoupling mosfets for 1+1 and N+1 redundancy
- Automatic load sharing
- Reverse input polarity protection
- Easy wiring: distribution terminal for negative pole included
- Redundancy status indicator
- Suitable for Zone 2/Div. 2 mounting
Show more


Note
All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
DE
- DE
- EN
- ES
- FR
- PL
DatasheetFunctionClassificationInformative LiteratureProduct DocumentationDesign / SimulationApprovalsRelated Products
Technical data of PS1000-D2-24.20.RM
Voltage drop | input to output 0.1 ... 0.5 V at input 2 x 5 A 0.2 ... 0.5 V at input 2 x 10 A 0.24 ... 0.5 V at input 2 x 12 A load share dependent | |
Power dissipation | 1.7 W no load 2.6 ... 4.7 W at input 2 x 5 A 5.6 ... 8.7 W at input 2 x 10 A |
Rated voltage | Ur | 24 ... 28 V |
Voltage range | 18 ... 35 V DC | |
Current | 2 x 12 A at ambient temperature < 45 °C (113 °F) 2 x 10 A at ambient temperature 70 °C (158 °F) 2x 17 mA for max. 5 s for lower output currents see technical information |
Voltage range | 24 ... 28 V DC | |
Current | 24 A at ambient temperature < 45 °C (113 °F) 20 A at ambient temperature < 70 °C (158 °F) 32.5 A for max. 5 s max. 26 A in overload or short circuit mode (voltage < 6 V DC) |
Connection | terminals 13, 14 : relay contact load share terminals 23, 24 : relay contact redundancy | |
Output type | relay contact load share - contact is closed if the adjustment of the output voltages are sufficient - contact is open if an even load share does not occur and readjustment of the output voltage is required relay contact redundancy - contact is closed if no fault is detected - contact is open if one or both input voltages are below 22 V DC or above 30 V DC - contact is open if the output current is higher than the adjusted value of the output current - contact is open if an internal defect of the device is detected | |
Contact loading | max. 60 V DC/0.3 A ; 30 V DC/1 A ; 30 V AC/0.5 A resistive load min. 1 mA at 5 V DC |
Input/Output | SELV/PELV |
Display elements | LED green: output status - LED lights up if the output current is smaller than the adjusted value of the output current LEDs green: load share status - LEDs indicate the load share status between the two power supplies LED green: redundancy status - LED lights up if no fault is detected - LED flashes if one ore both input values are below 22 V or above 30 V - LED flashes if the output current is higher than the adjusted value of the output current - LED flashes if an internal defect is detected | |
Control elements | rotary switch | |
Configuration | setting of the output current via rotary switch - switch setting to 5 A in combination with two 5A power supplies (1+1 redundancy) - switch setting to 10 A in combination with two 10A power supplies (1+1 redundancy) - switch setting to 20 A for N+1 redundant systems |
Electromagnetic compatibility | |||||
| |||||
Low voltage | |||||
| |||||
RoHS | |||||
|
Degree of protection | EN 60529 | |
Shock resistance | EN 60068-2-27 | |
Vibration resistance | EN 60068-2-6 |
Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) , see technical information | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Relative humidity | 5 ... 95 %, noncondensing | |
Shock resistance | 20 g , 11 ms or 30 g , 6 ms | |
Vibration resistance | 2 ... 17.8 Hz : ± 1.6 mm , 17.8 ... 500 Hz : 2 g |
Housing material | aluminum alloy , galvanized steel | ||||||||||
Degree of protection | IP20 | ||||||||||
Connection | |||||||||||
| |||||||||||
Mass | approx. 310 g | ||||||||||
Dimensions | 32 x 124 x 117 mm (W x H x D) , without DIN mounting rail | ||||||||||
| |||||||||||
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
ATEX approval | ||||||||
| ||||||||
Directive conformity | ||||||||
|
UL approval | E223176 | ||||||||||
IECEx approval | |||||||||||
|
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |