Serviceline Industrial Sensors
Serviceline Explosion Protection

Mounting adapter MONAD-M08-1,25-1,2Z-BSPT/36

MONAD-M08-1,25-1,2Z-BSPT/36
  • Usable for VIM3* / VIM6* vibration sensors with external thread
  • Robust due to stainless steet 1.4404 / AISI 316L (V4A)
  • Screw-in thread for simple installation

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Ladda ned datablad som PDF::


Utdrag ur datablad: Tekniska data för  MONAD-M08-1,25-1,2Z-BSPT/36

Product Description
Mounting adapter for VIM3*/VIM6* vibration sensors, internal thread M8 x 1.25 x 10, external thread NPT1/2", screw-in depth 24
General specifications
Suitable componentsVIM3* vibration sensors
VIM6* vibration sensors
Mechanical specifications
External threadfor machine mounting
Thread typeNPT
Thread sizeNPT 1/2''
Screw-in depth24 mm
Internal threadfor sensor mounting
Thread typemetric
Thread sizeM8 x 1.25
Thread length10 mm
Length41 mm
Diameter27.71 mm
MaterialStainless steel 1.4404 / AISI 316L
Mass115 g

Classifications

SystemClasscode
ECLASS 13.027273701
ECLASS 12.027273701
ECLASS 11.027273792
ECLASS 10.0.127273792
ECLASS 9.027273792
ECLASS 8.027279202
ECLASS 5.127279202
ETIM 9.0EC003015
ETIM 8.0EC003015
ETIM 7.0EC003015
ETIM 6.0EC003015
ETIM 5.0EC003015
UNSPSC 12.131162301

Details: MONAD-M08-1,25-1,2Z-BSPT/36

Design / Simulation: MONAD-M08-1,25-1,2Z-BSPT/36

Language Selection:
CADLanguageFile TypeFile Size
CAD 3-D / CAD 3-DALLSTP74 KB
CAD Portal / CAD PortalALLLINK---

Associated Products: MONAD-M08-1,25-1,2Z-BSPT/36

Accessory of
Vibration sensor with switching output and analog current output, Series: Performance Line, Measured variable: Vibration velocity, Output type: analog output, current
output of the vibration variable, Output type: PNP, Ordinary Location: E468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only.
adapters providing field wiring on request, Adaption: M8 x 1.25 external thread
, Connection type: plugfa
Vibration sensor with switching output and analog current output, Series: Performance Line, Measured variable: Vibration velocity, Output type: analog output, current
output of the vibration variable, Output type: PNP, Ordinary Location: E468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only.
adapters providing field wiring on request, Adaption: M8 x 1.25 external thread
, Connection type: plugfa
Vibration sensor with switching output and analog current output, Series: Performance Line, Measured variable: Vibration velocity, Output type: analog output, current
output of the vibration variable, Output type: PNP, Ordinary Location: E468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only.
adapters providing field wiring on request, Adaption: M8 x 1.25 external thread
, Connection type: plugfa
Vibration sensor with analog current output, Series: Performance Line, Measured variable: Vibration velocity, Output type: analog output, current
output of the vibration variable, Ordinary Location: E468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only.
adapters providing field wiring on request, Adaption: M8 x 1.25 external thread
, Connection type: plugfa
Vibration sensor with analog current output, Series: Performance Line, Measured variable: Vibration acceleration, Vibration acceleration: 0 ... 10 g rms, Output type: analog output, current
output of the vibration variable, Ordinary Location: E468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only.
adapters providing field wiring on request, Adaption: M8 x 1.25 external thread
, Connection type: plugfa
Vibration sensor with IO-Link and programmable switching output or analog current output, Series: Performance Line, Measured variable: Vibration velocity
Vibration acceleration
Temperature, Vibration acceleration: 0 ... 10 g rms, Interface type: IO-Link (via C/Q = Pin 4), Device profile: Identification and Diagnosis - I&D, Output type: C/Q - Pin 4 in SIO mode (switching signal of the measured variable is programmable)fa
Vibration sensor with IO-Link and programmable switching output or analog current output, Series: Performance Plus Line, Measured variable: Vibration velocity
Vibration acceleration
Bearing status parameter
Crest factor
Temperature, Vibration acceleration: 0 ... 34 g rms, Vibration acceleration: 0 ... 48 g peak value per 1 s, Vibration acceleration: -48 ... 48 g by means of BLOB transferfa
Vibration sensor with analog current output and increased temperature resistance, Series: Performance Line, Measured variable: Vibration velocity, Output type: analog output, current
output of the vibration variable, Ordinary Location: E468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only.
adapters providing field wiring on requestfa
Vibration sensor with analog current output and increased temperature resistance, Series: Performance Line, Measured variable: Vibration velocity
Temperature, Output type: analog output, current
output of the vibration variable, Output type: analog output, current
output of the temperaturefa
Vibration sensor with analog current output and increased temperature resistance, Series: Performance Line, Measured variable: Vibration velocity
Temperature, Output type: analog output, current
output of the vibration variable, Output type: analog output, current
output of the temperaturefa
Vibration sensor with analog current output and increased temperature resistance, Series: Performance Line, Measured variable: Vibration acceleration, Vibration acceleration: 0 ... 10 g rms, Output type: analog output, current
output of the vibration variable, Ordinary Location: E468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only.
adapters providing field wiring on requestfa
Vibration sensor with analog current output, increased temperature resistance, suitable up to Zone 1/21 with type of protection explosionproof enclosure, Series: Performance Plus Line, Measured variable: Vibration velocity, Output type: analog output, current
output of the vibration variable, Equipment protection level Gb: IECEx CSAE 22.0042X, Equipment protection level Db: IECEx CSAE 22.0042X, Equipment protection level Gb: CSANe 21 ATEX 1074 X, Equipment protection level Db: CSANe 21 ATEX 1074 Xfa
Vibration sensor with analog current output, increased temperature resistance, suitable up to Zone 1/21 with type of protection explosionproof enclosure, Series: Performance Plus Line, Measured variable: Vibration velocity, Output type: analog output, current
output of the vibration variable, Equipment protection level Gb: IECEx CSAE 22.0042X, Equipment protection level Db: IECEx CSAE 22.0042X, Equipment protection level Gb: CSANe 21 ATEX 1074 X, Equipment protection level Db: CSANe 21 ATEX 1074 Xfa
Vibration sensor with analog current output, increased temperature resistance, suitable up to Zone 1/21 with type of protection explosionproof enclosure, Series: Performance Plus Line, Measured variable: Vibration velocity
Temperature, Output type: analog output, current
output of the vibration variable, Equipment protection level Gb: IECEx CSAE 22.0042X, Equipment protection level Db: IECEx CSAE 22.0042X, Equipment protection level Gb: CSANe 21 ATEX 1074 Xfa
Vibration sensor with analog current output and increased temperature resistance, Series: Performance Line, Measured variable: Vibration acceleration, Vibration acceleration: 0 ... 10 g rms, Output type: analog output, current
output of the vibration variable, Ordinary Location: E468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only.
adapters providing field wiring on requestfa
Vibration sensor with analog current output, increased temperature resistance, suitable up to Zone 1/21 with type of protection intrinsic safety, Series: Performance Plus Line, Measured variable: Vibration velocity, Output type: analog output, current
output of the vibration variable, Equipment protection level Gb: IECEx CSAE 22.0042X, Equipment protection level Db: IECEx CSAE 22.0042X, Equipment protection level Gb: CSANe 21 ATEX 1074 X, Equipment protection level Db: CSANe 21 ATEX 1074 Xfa
Vibration sensor with analog current output, increased temperature resistance, suitable for Class I/II and Division 2, Series: Performance Plus Line, Measured variable: Vibration velocity, Output type: analog output, current
output of the vibration variable, Ordinary Location: E468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only.
adapters providing field wiring on request, Hazardous Location: E106378fa
De fotoelektriska sensorerna i R10x- och R20x-serierna

För första gången finns ett konsekvent utbud av produkter med fotoelektriska funktionsprinciper och innovativa tekniker i identiska kapslingar. Användarna kommer att uppskatta detta enhetliga driftskoncept genom hela sortimentet. Upptäck serierna R100, R101, R103, R200 och R201 …

Fotocell ML100

Oavsett om det gäller glas, solcellsskivor eller kretskort: De fotoelektriska sensorerna i ML100-serien är exakt skräddarsydda för att uppfylla kraven för olika komplexa detekteringsuppgifter. Läs mer om sortimentet …