|
| |
Product |
|
|
'KCD0-SD3-Ex1.1045' är nu tillagd på din bevakniningslista.
KCD0-SD3-Ex1.1045` finns redan på din bevakniningslista.
|
1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 10 V DC, Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: loop powered, Type: logic input, Type [2]: field device supply, Test pulse immunity, Field device: 1 x Valve, Field device [2]: 1 x audible alarm, Field device [3]: 1 x visual alarmpa |
|
|
|
'KCD0-SD3-Ex1.1245' är nu tillagd på din bevakniningslista.
KCD0-SD3-Ex1.1245` finns redan på din bevakniningslista.
|
1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: loop powered, Type: logic input, Type [2]: field device supply, Test pulse immunity, Field device: 1 x Valve, Field device [2]: 1 x audible alarm, Field device [3]: 1 x visual alarmpa |
|
|
|
'KCD2-SLD-Ex1.1065' är nu tillagd på din bevakniningslista.
KCD2-SLD-Ex1.1065` finns redan på din bevakniningslista.
|
1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 65 mA at 10 V DC, Line fault transparency (LFT), Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Line fault transparency, Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC loop powered, Type: logic input, Type [2]: field device supply, Test pulse immunity, Field device: 1 x Valvepa |
|
|
|
'KCD2-SLD-Ex1.1245' är nu tillagd på din bevakniningslista.
KCD2-SLD-Ex1.1245` finns redan på din bevakniningslista.
|
1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 12 V DC, Line fault transparency (LFT), Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Line fault transparency, Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC loop powered, Type: logic input, Type [2]: field device supply, Test pulse immunity, Field device: 1 x Valvepa |
|
|
|
'KFD0-SD2-Ex1.10100' är nu tillagd på din bevakniningslista.
KFD0-SD2-Ex1.10100` finns redan på din bevakniningslista.
|
1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 100 mA at 10 V DC, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 3, Rated voltage: 20 ... 35 V DC , loop powered, Type: field device supply, Field device: 1 x Valve, Field device [2]: 1 x audible alarm, Field device [3]: 1 x visual alarm, Current: ≥ 100 mA, Voltage: ≥ 9.5 Vpa |
|
|
|
'KFD0-SD2-Ex1.1180' är nu tillagd på din bevakniningslista.
KFD0-SD2-Ex1.1180` finns redan på din bevakniningslista.
|
1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 80 mA at 11 V DC, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 3, Rated voltage: 20 ... 35 V DC , loop powered, Type: field device supply, Field device: 1 x Valve, Field device [2]: 1 x audible alarm, Field device [3]: 1 x visual alarm, Current: ≥ 80 mA, Voltage: ≥ 11 Vpa |
|
|
|
'KFD2-VM-Ex1.35.L' är nu tillagd på din bevakniningslista.
KFD2-VM-Ex1.35.L` finns redan på din bevakniningslista.
|
1-channel isolated barrier, 24 V DC supply (Power Rail), Output 15.3 V DC at 17 mA, 3 logic inputs with AND/OR logic, Service port for isolator function test, Housing width: 20 mm, Number of channels: 1-channel, Rated voltage: 20 ... 30 V DC, Type: logic input, Field device: 1 x Valve, Current: typ. 18 mA, Voltage: typ. 16 Vpa |
|
|
|
'KCD0-SD3-Ex2.1545-Y1' är nu tillagd på din bevakniningslista.
KCD0-SD3-Ex2.1545-Y1` finns redan på din bevakniningslista.
|
2-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 15 V DC, Test pulse immunity, Housing width 12.5 mm, Housing width: 12.5 mm, Number of channels: 2-channel, Rated voltage: loop powered, Type: logic input, Type [2]: field device supply, Test pulse immunity, Field device: 2 x Valve, Field device [2]: 2 x audible alarm, Field device [3]: 2 x visual alarm, Current: typ. 45 mA, Voltage: ≥ 15 Vpa |
|
|
|
'KCD0-SD3-Ex2.1545-Y1.SP' är nu tillagd på din bevakniningslista.
KCD0-SD3-Ex2.1545-Y1.SP` finns redan på din bevakniningslista.
|
2-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 15 V DC, Test pulse immunity, Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Housing width: 12.5 mm, Number of channels: 2-channel, Rated voltage: loop powered, Type: logic input, Type [2]: field device supply, Test pulse immunity, Field device: 2 x Valve, Field device [2]: 2 x audible alarm, Field device [3]: 2 x visual alarm, Current: typ. 45 mA, Voltage: ≥ 15 Vpa |
|
|
|
'KCD2-SLD-Ex1.1045' är nu tillagd på din bevakniningslista.
KCD2-SLD-Ex1.1045` finns redan på din bevakniningslista.
|
1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 10 V DC, Line fault transparency (LFT), Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Line fault transparency, Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC loop powered, Type: logic input, Type [2]: field device supply, Test pulse immunity, Field device: 1 x Valvepa |
|
|
| |