Serviceline Industrial Sensors
Serviceline Explosion Protection

Static Inclination Sensors

Choose your product

Next PageLast Page
Product


E1-Type approval, Measuring range 0 ... 360°, High shock resistance, Extended temperature range
-40 ... +85 °C, CANopen interface, Increased noise immunity 100 V/mfa


E1-Type approval, Measuring range 0 ... 360°, Analog output 4 mA ... 20 mA, Evaluation limits can be taught-in, 2 programmable switch outputs, High shock resistance, Increased noise immunity 100 V/mfa


E1-Type approval, Measuring range 0 ... 360°, Analog output 4 mA ... 20 mA, Evaluation limits can be taught-in, 2 programmable switch outputs, High shock resistance, Increased noise immunity 100 V/mfa


E1-Type approval, Measuring range 0 ... 360°, Analog output 4 mA ... 20 mA, Evaluation limits can be taught-in, 2 programmable switch outputs, High shock resistance, Increased noise immunity 100 V/mfa


E1-Type approval, Measuring range 0 ... 360°, High shock resistance, Extended temperature range
-40 ... +85 °C, CANopen interface, Increased noise immunity 100 V/mfa

Inertial measurement unit for inclination, acceleration and rotation rate measurement in 3-axis each, Dynamic inclination measurement despite external acceleration, Adjustable ranges for compensation of external accelerations, disturbances, Adjustable thresholds for detection of measured value overruns, Measurement of inclination, acceleration and rotation rate in 3 axis each, CAN bus with CANopenfa

Inertial measurement unit for inclination, acceleration and rotation rate measurement in 3-axis each, Dynamic inclination measurement despite external acceleration, Adjustable ranges for compensation of external accelerations, disturbances, Adjustable thresholds for detection of measured value overruns, Measurement of inclination, acceleration and rotation rate in 3 axis each, CAN bus with SAE J1939 protocolfa

E1-Type approval, Measuring range 0 ... 360°, Analog output 4 mA ... 20 mA, Evaluation limits can be taught-in, 2 programmable switch outputs, High shock resistance, Increased noise immunity 100 V/mfa

E1-Type approval, Measuring range 0 ... 360°, Analog output 0 V ... 5 V, Evaluation limits can be taught-in, 2 programmable switch outputs, High shock resistance, Increased noise immunity 100 V/mfa

E1-Type approval, Measuring range 0 ... 360°, Analog output 0 V ... 5 V, Evaluation limits can be taught-in, 2 programmable switch outputs, High shock resistance, Increased noise immunity 100 V/mfa
Next PageLast Page

Filtrera sökning