Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Ladda ned datablad som PDF::
Utdrag ur datablad: Tekniska data för
ML100-8-H-100/95/127/162
Product Description |
Diffuse mode sensor with special light spots for detecting PCBs, background suppression, miniature design, 100 mm detection range, red light, light on, NPN outputs, M8 plug |
General specifications |
Detection range | 20 ... 100 mm |
Detection range min. | 10 ... 25 mm |
Detection range max. | 25 ... 100 mm |
Adjustment range | 25 ... 100 mm |
Reference target | standard white, 100 mm x 100 mm |
Light source | LED |
Light type | modulated visible red light |
Polarization filter | no |
Black-white difference (6 %/90 %) | < 20 % |
Diameter of the light spot | 3 light spots, spotsize 4 mm at a distance of 50 mm, spots are 8 mm apart; spotsize 2.5 mm at a distance of 80 mm, spots are 12 mm apart; spotsize 4 mm at a distance of 100 mm, spots are 15 mm apart (outer spot to outer spot) |
Optical face | frontal |
Ambient light limit | EN 60947-5-2:2007+A1:2012 |
Functional safety related parameters |
MTTFd | 1100 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means |
Operation indicator | LED green: power on |
Function indicator | LED yellow: lights when object is detected , flashes when in adjustment mode |
Control elements | Sensing range adjuster |
Control elements | Light-on/dark-on changeover switch |
Electrical specifications |
Operating voltage | 10 ... 30 V DC |
Ripple | max. 10 % |
No-load supply current | < 15 mA |
Output |
Switching type | The switching type of the sensor is adjustable. The default setting is: light-on |
Signal output | 2 NPN outputs, independent short-circuit protected , reverse polarity protected , open collector transistor |
Switching voltage | max. 30 V DC |
Switching current | max. 100 mA , resistive load |
Voltage drop | ≤ 1.5 V DC |
Switching frequency | 500 Hz |
Response time | 1 ms |
Conformity |
Product standard | EN 60947-5-2 |
Approvals and certificates |
UL approval | cULus Listed, Class 2 Power Source or listed Power Supply with a limited voltage output with (maybe integrated) fuse (max. 3.3 A according UL248), Type 1 enclosure |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Ambient temperature | -30 ... 60 °C (-22 ... 140 °F) |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) |
Mechanical specifications |
Degree of protection | IP67 |
Connection | Connector M8 x 1 , 4-pin |
Material | |
| Housing | PC (Polycarbonate) |
| Optical face | PMMA |
Mass | approx. 10 g |
Tightening torque, fastening screws | 0.6 Nm |
Dimensions | |
| Height | 31 mm |
| Width | 11 mm |
| Depth | 20 mm |
Classifications
System | Classcode |
ECLASS 13.0 | 27270903 |
ECLASS 12.0 | 27270903 |
ECLASS 11.0 | 27270904 |
ECLASS 10.0.1 | 27270904 |
ECLASS 9.0 | 27270904 |
ECLASS 8.0 | 27270904 |
ECLASS 5.1 | 27270904 |
ETIM 9.0 | EC002719 |
ETIM 8.0 | EC002719 |
ETIM 7.0 | EC002719 |
ETIM 6.0 | EC002719 |
ETIM 5.0 | EC002719 |
UNSPSC 12.1 | 39121528 |
Details:
ML100-8-H-100/95/127/162
Product Documentation:
ML100-8-H-100/95/127/162
Design / Simulation:
ML100-8-H-100/95/127/162
Approvals:
ML100-8-H-100/95/127/162
Associated Products:
ML100-8-H-100/95/127/162
Accessories |
|
|
|
Female cordset single-ended M8 straight A-coded, 4-pin, PUR cable greyfa |
|
|
|
|
Female cordset single-ended M8 angled A-coded, 4-pin, PUR cable greyfa |
|
|
|
|
Mounting aid for round steel ø 12 mm or sheet 1.5 mm ... 3 mmfa |
|
|
|
|
Mounting aid for ML100 series, Mounting bracketfa |
|
|
|
|
Mounting aid for round steel ø 12 mm or sheet 1.5 mm ... 3 mmfa |
|
|
|
|
Mounting aid for ML100 series, Mounting bracketfa |
|
|
|
|
Mounting aid for ML100 series, Mounting bracketfa |
|