Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Ladda ned datablad som PDF::
Utdrag ur datablad: Tekniska data för
OQD8000-R300-2EP-V1-L
Product Description |
Diffuse sensor with measurement core technology |
General specifications |
Detection range | 0.03 ... 8 m |
Adjustment range | 0.05 ... 8 m |
Reference target | Kodak white (90%) |
Light type | modulated visible red light |
Laser nominal ratings | |
| Note | LASER LIGHT , DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS |
| Laser class | 1M |
| Wave length | 660 nm |
| Beam divergence | < 25 mrad |
| Pulse length | 4 ns |
| Repetition rate | 250 kHz |
| max. pulse energy | < 2.4 nJ |
Black-white difference (6 %/90 %) | < 0.5 % |
Angle deviation | max. ± 2° |
Measuring method | Pulse Ranging Technology (PRT) |
Diameter of the light spot | vertical 60 mm , horizontal 30 mm at a distance of 2 m |
Ambient light limit | 50000 Lux |
Functional safety related parameters |
MTTFd | 100 a |
Mission Time (TM) | 10 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means |
Operation indicator | LED green |
Function indicator | 2 LEDs yellow for switching state |
Teach-in indicator | Teach-In: LED green/yellow equiphase flashing; 2.5 Hz Teach Error:LED green/yellow non equiphase flashing; 8.0 Hz |
Control elements | 5-step rotary switch for operating modes selection (threshold setting and operating modes) |
Control elements | Switch for setting the threshold values |
Electrical specifications |
Operating voltage | 10 ... 30 V DC |
Ripple | 10 % within the supply tolerance |
No-load supply current | ≤ 80 mA / 24 V DC |
Time delay before availability | < 0.7 s , for temperatures <-30°C compliance of the specification 5 mins after power on |
Output |
Signal output | 2 push-pull (4 in 1) outputs, short-circuit protected, reverse polarity protected |
Switching voltage | max. 30 V DC |
Switching current | max. 100 mA |
Switching frequency | 50 Hz |
Response time | 5 ms |
Conformity |
Product standard | EN 60947-5-2 |
Laser safety | EN 60825-1:2014 |
Approvals and certificates |
UL approval | E87056 , cULus Listed , class 2 power supply , type rating 1 |
FDA approval | IEC 60825-1:2014 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007 |
Ambient conditions |
Ambient temperature | -40 ... 55 °C (-40 ... 131 °F) |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) |
Mechanical specifications |
Degree of protection | IP67 |
Connection | 4-pin, M12 x 1 connector |
Material | |
| Housing | Plastic ABS |
| Optical face | PMMA |
Mass | 90 g |
Dimensions | |
| Height | 88 mm |
| Width | 25.8 mm |
| Depth | 54.3 mm |
Classifications
System | Classcode |
ECLASS 13.0 | 27270903 |
ECLASS 12.0 | 27270903 |
ECLASS 11.0 | 27270903 |
ECLASS 10.0.1 | 27270903 |
ECLASS 9.0 | 27270903 |
ECLASS 8.0 | 27270903 |
ECLASS 5.1 | 27270903 |
ETIM 9.0 | EC001821 |
ETIM 8.0 | EC001821 |
ETIM 7.0 | EC001821 |
ETIM 6.0 | EC001821 |
ETIM 5.0 | EC001821 |
UNSPSC 12.1 | 39121528 |
Details:
OQD8000-R300-2EP-V1-L
Product Documentation:
OQD8000-R300-2EP-V1-L
Design / Simulation:
OQD8000-R300-2EP-V1-L
Approvals:
OQD8000-R300-2EP-V1-L
Associated Products:
OQD8000-R300-2EP-V1-L
Accessories |
|
|
|
Mounting aid for round steel ø 12 mm or sheet 1.5 mm ... 3 mmfa |
|
|
|
|
Mounting bracket: mounting aid for sensors in the RL* seriesfa |
|
|
|
|
Mounting aid for RL* seriesfa |
|
|
|
|
Mounting bracket for rear wall mountingfa |
|
|
|
|
dove tail mounting clampfa |
|
|
|
|
dove tail mounting clampfa |
|
|
|
|
Metal enclosure for inserting protective panes or aperturesfa |
|
|
|
|
Mounting and fine adjustment device for sensors from the 28 seriesfa |
|
|
|
|
Mounting aid for round steel ø 12 mm or sheet 1.5 mm ... 3 mmfa |
|