请注意:所有以Pepperl + Fuchs GmbH或Pepperl + Fuchs AG名义发行的产品相关文件,例如证书,合格声明等,同样适用于Pepperl + Fuchs SE。
將完整的規格書下載為PDF:
產品描述 |
---|
Single or multi-beam light curtain for individual protection according to DIN 18650/EN16005 |
General specifications | ||
---|---|---|
Detection range min. | 0 ... 1500 mm | |
Detection range max. | 0 ... 2500 mm | |
Reference target | Minimum degree of reflection of the floor: 6 % Minimum degree of reflection to objects being detected: 0 % |
|
Light source | IRED | |
Light type | modulated infrared light 875 nm | |
Black-white difference (6 %/90 %) | < 2 % at 2000 mm sensor range | |
Number of beams | 1 (number of built-in sensor modules AIR) | |
Operating mode | Background evaluation | |
Diameter of the light spot | 1.1 cm x 8.3 cm at 2000 mm sensor range | |
Resolution | Reference object CA DIN 186850-1/EN 16005 in all applicable locations | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 1 | |
Performance level (PL) | PL c | |
Category | Cat. 2 | |
MTTFd | 880 a per module | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 90 % | |
Indicators/operating means | ||
Function indicator | LED red/green | |
Control elements | Sensing range adjuster ; Adjuster for edge monitoring left/right | |
Electrical specifications | ||
Operating voltage | 24 V DC +/- 20 % | |
No-load supply current | 75 mA | |
Input | ||
Test input | active at U = 11 V DC at 30 V DC inactive at U = -3 V DC at 5 V DC | |
Output | ||
Switching type | Relay de-energized at object inside the scanning range | |
Signal output | Relay, 1 alternator | |
Switching voltage | 5 V ... 30 V AC/DC | |
Switching current | max. 300 mA | |
Response time | ≤ 70 ms | |
Conformity | ||
Functional safety | ISO 13849-1 | |
Product standard | EN 12978 ; EN 16005 ; DIN 18650 | |
Approvals and certificates | ||
CCC approval | CCC approval / marking not required for products rated ≤36 V | |
TÜV approval | TÜV NORD | |
Ambient conditions | ||
Ambient temperature | -10 ... 50 °C (14 ... 122 °F) | |
Relative humidity | Humidity at 20 °C: < 90 % Humidity at 60 °C: < 50 % |
|
Mechanical specifications | ||
Housing length L | 750 mm | |
Mounting height | max. 2500 mm | |
Degree of protection | IP52 , IP54 Optional (with special seal) | |
Connection | screw terminals ; Cable cross-section 0.3 mm2 ... 1.3 mm2 (AWG26-16), single-stranded/multistranded CU | |
Material | ||
Housing | aluminum / ABS | |
Optical face | PMMA | |
Dimensions | ||
Height | 42 mm | |
Depth | 37 mm | |
Length | 750 mm | |
Cable length | max. 30 m | |
Note | Safety fuse ≤ 1 A (slow-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. |
System | Classcode |
---|---|
ECLASS 13.0 | 27270913 |
ECLASS 12.0 | 27270913 |
ECLASS 11.0 | 27270913 |
ECLASS 10.0.1 | 27270913 |
ECLASS 9.0 | 27270913 |
ECLASS 8.0 | 27270913 |
ECLASS 5.1 | 27270903 |
ETIM 9.0 | EC002550 |
ETIM 8.0 | EC002550 |
ETIM 7.0 | EC002550 |
ETIM 6.0 | EC002550 |
ETIM 5.0 | EC001821 |
UNSPSC 12.1 | 39121528 |
We are sorry, there are no documents for your language selection. Please select another language. |
Brief Instructions | 語言 | 檔案類型 | 檔案尺寸 |
---|---|---|---|
Brief Instructions - for Adjusting TopScan-S / Kurzanleitung - zur Einrichtung des TopScan-S | ALL | 471 KB | |
Hints for installation of moduls AIR16-S and AIR17-S on device TopScan-S / Einstellhinweise zur Einrichtung der Module AIR16-S und AIR17-S beim Gerät TopScan-S | ALL | 264 KB | |
Manuals | |||
Manual | ENG | 2122 KB |
CAD | 語言 | 檔案類型 | 檔案尺寸 |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 797 KB |
CAD Portal / CAD Portal | ALL | LINK | --- |
Certificates | 證書號碼 | 語言 | 檔案類型 | 檔案尺寸 |
---|---|---|---|---|
/cert/cert0951c.pdf | 44 780 13 095706 | ALL | 109 KB | |
Europe TUV Nord EC-Type Exam. Certificate Functional Safety | 44 205 13 095705 | ALL | 56 KB | |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-0118E | ALL | 165 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|