Accessory of |
|
|
|
Measuring range 0 ... 14 mm, 2 programmable switch outputs, Switching element function: PNP Dual NO, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: PNP (2 Channels), UL approval: cULus Listed, Class 2 Power Source, Type 1 enclosure, Connection type: 5 x 0.14 mm2 , screened 2 m PUR cable, Degree of protection: IP65, Housing: Zinc diecast, nickel-plated cover , PBTfa |
|
|
|
|
Analog output 0 ... 10 V, Measuring range 0 ... 14 mm, Scalable measuring range programmable via cable, Switching element function: Analog voltage output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: 1 voltage output: 0 ... 10 V, Connection type: fixed cable with plug, Degree of protection: IP65, Housing: Zinc diecast, nickel-plated cover , PBT, Threading: M12 x 1fa |
|
|
|
|
Measuring range 0 ... 14 mm, 2 programmable switch outputs, Switching element function: PNP Dual NO, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: PNP (2 Channels), Connection type: fixed cable with plug, Degree of protection: IP65, Housing: Zinc diecast, nickel-plated cover , PBT, Threading: M12 x 1fa |
|
|
|
|
IO-Link interface for service and process data, Measuring range 0 ... 15 mm, Switching element function: Push-pull (4 in 1) output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4), Output type: 1 Push-pull (4 in 1) output , short-circuit protected , reverse polarity protected , overvoltage protected , programmable, UL approval: cULus Listed, Class 2 Power Source, Type 1 enclosure, Connection type: fixed cable with plugfa |
|
|
|
|
Analog output 0 ... 10 V, Measuring range 0 ... 14 mm, Scalable measuring range programmable via cable, Switching element function: Analog voltage output, Output polarity: DC, Type of voltage: DC, Output type: 1 voltage output: 0 ... 10 V, Connection type: 1 m, PUR cable, Housing: Zinc diecast, nickel-plated cover , PBTfa |
|
|
|
|
Analog output 0 ... 10 V, Measuring range 0 ... 14 mm, Scalable measuring range programmable via cable, Switching element function: Analog voltage output, Output polarity: DC, Type of voltage: DC, Output type: 1 voltage output: 0 ... 10 V, Connection type: fixed cable with plug, Housing: Zinc diecast, nickel-plated cover , PBT, Threading: M12 x 1fa |
|
|
|
|
IO-Link interface for service and process data, Measuring range 0 ... 15 mm, Switching element function: Push-pull (4 in 1) output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4), Output type: 1 Push-pull (4 in 1) output , short-circuit protected , reverse polarity protected , overvoltage protected , programmable, UL approval: cULus Listed, Class 2 Power Source, Type 1 enclosure, Connection type: cablefa |
|
|
|
|
Analog output 0 ... 10 V, Measuring range 0 ... 14 mm, Scalable measuring range programmable via cable, Switching element function: Analog voltage output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: 1 voltage output: 0 ... 10 V, UL approval: cULus Listed, Class 2 Power Source, Type 1 enclosure, Connection type: 5 x 0.14 mm2 , screened 2 m PUR cable, Degree of protection: IP65fa |
|
|
|
|
IO-Link interface for service and process data, Measuring range 0 ... 15 mm, Switching element function: Push-pull (4 in 1) output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4), Output type: 1 Push-pull (4 in 1) output , short-circuit protected , reverse polarity protected , overvoltage protected , programmable, UL approval: cULus Listed, Class 2 Power Source, Type 1 enclosure, Connection type: cablefa |
|
|
|
|
IO-Link interface for service and process data, Measuring range 0 ... 15 mm, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4), Output type: 1 push-pull (4 in 1) output, short-circuit protected, reverse polarity protected, overvoltage protected, UL approval: cULus Listed, Class 2 Power Source, Type 1 enclosure, Connection type: 5-pin, M12 x 1 connector, Degree of protection: IP67fa |
|
|
|
|
Analog output 0 V ... 10 V/4 mA ... 20 mA, Measuring range 0 ... 104 mm, Switching element function: analog, current or voltage output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: 1 current output: 4 ... 20 mA 1 voltage output: 0 ... 10 V, UL approval: cULus Listed, General Purpose, Class 2 Power Source, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: 4-pin, M12 x 1 connector, Degree of protection: IP67fa |
|
|
|
|
Parameterization and diagnosis via IO-Link, Analog output 0 ... 10 V, Measuring range 0 ... 14 mm, Shielded line 2 m, Switching element function: Analog voltage output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Interface type: IO-Link, Output type: voltage output 0 ... 10 V, UL approval: cULus Listed, Class 2 Power Source, Type 1 enclosure, CCC approval: CCC approval / marking not required for products rated ≤36 Vfa |
|
|
|
|
Parameterization and diagnosis via IO-Link, Analog output 0 ... 10 V, Measuring range 0 ... 14 mm, Switching element function: Analog voltage output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Interface type: IO-Link, Output type: voltage output 0 ... 10 V, UL approval: cULus Listed, Class 2 Power Source, Type 1 enclosure, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Cable connectorfa |
|
|
|
|
Parameterization and diagnosis via IO-Link, Analog output 0 ... 10 V, Measuring range 0 ... 14 mm, Switching element function: Analog voltage output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Interface type: IO-Link, Output type: voltage output 0 ... 10 V, UL approval: cULus Listed, Class 2 Power Source, Type 1 enclosure, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: M8 x 1 connector, 4-pinfa |
|
|
|
|
Analog output 0 ... 10 V, Scalable measuring range, programmable via key, Measuring range 0 ... 14 mm, Switching element function: Analog voltage output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: 1 voltage output: 0 ... 10 V, UL approval: cULus Listed, Class 2 Power Source, Type 1 enclosure, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: M8 x 1 connector, 3-pinfa |
|
|
|
|
Analog output 0 ... 10 V, Measuring range 0 ... 14 mm, Switching element function: Analog voltage output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: voltage output 0 ... 10 V, UL approval: cULus Listed, Class 2 Power Source, Type 1 enclosure, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: fixed cable with plug, Housing material: diecast zinc, not laquered or coatedfa |
|
|
|
|
Parameterization and diagnosis via IO-Link, 3 configurable switching frames, Measuring range 0 ... 14 mm, Shielded line 2 m, Output polarity: DC, Type of voltage: DC, Interface type: IO-Link, Output type: 2 Push-pull (4 in 1) outputs , 1 switch output PNP , short-circuit protected , reverse polarity protected , overvoltage protected , programmable, UL approval: cULus Listed, Class 2 Power Source, Type 1 enclosure, CCC approval: CCC approval / marking not required for products rated ≤36 Vfa |
|
|
|
|
Parameterization and diagnosis via IO-Link, 3 configurable switching frames, Measuring range 0 ... 14 mm, Output polarity: DC, Type of voltage: DC, Interface type: IO-Link, Output type: 2 Push-pull (4 in 1) outputs , 1 switch output PNP , short-circuit protected , reverse polarity protected , overvoltage protected , programmable, UL approval: cULus Listed, Class 2 Power Source, Type 1 enclosure, CCC approval: CCC approval / marking not required for products rated ≤36 Vfa |
|
|
|
|
Parameterization and diagnosis via IO-Link, 3 configurable switching frames, Measuring range 0 ... 14 mm, Shielded line 2 m, Output polarity: DC, Type of voltage: DC, Interface type: IO-Link, Output type: 2 Push-pull (4 in 1) outputs , 1 switch output PNP , short-circuit protected , reverse polarity protected , overvoltage protected , programmable, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: 2 m PUR cable , screenedfa |
|
|
|
|
Parameterization and diagnosis via IO-Link, 2 configurable switching frames, Measuring range 0 ... 14 mm, Output polarity: DC, Type of voltage: DC, Interface type: IO-Link, Output type: 2 Push-pull (4 in 1) outputs , short-circuit protected , reverse polarity protected , overvoltage protected , programmable, UL approval: cULus Listed, Class 2 Power Source, Type 1 enclosure, CCC approval: CCC approval / marking not required for products rated ≤36 Vfa |
|