Incremental rotary encoder RHI90N

RHI90N
  • Compact design housing ∅90 mm
  • Variable hollow shaft from ∅16 mm ... ∅45 mm
  • Up to 50,000 ppr
  • Easy shaft clamping
  • Very high resolution and accuracy
  • Optional: Shaft insulation through heavy-duty plastic insulating sleeve

请注意:所有以Pepperl + Fuchs GmbH或Pepperl + Fuchs AG名义发行的产品相关文件,例如证书,合格声明等,同样适用于Pepperl + Fuchs SE。

將完整的規格書下載為PDF:


產品規格摘要:的技術資料  RHI90N

General specifications
Detection typephotoelectric sampling
Pulse countmax. 50000
Functional safety related parameters
MTTFd140 a
L1050 E+9 at 1750 rpm
Diagnostic Coverage (DC)0 %
Electrical specifications
Operating voltage10 ... 30 V DC or 5 V DC ± 5 % (see "Output circuit" in the ordering information)
No-load supply currentmax. 70 mA
Output
Output typepush-pull, incremental or RS-422, incremental
(see "Output circuit" in the ordering information)
Voltage drop< 2.5 V (push-pull, incremental)
Load currentmax. per channel 40 mA , short-circuit protected, reverse polarity protected (push-pull, incremental)
max. per channel 20 mA , short-circuit protected, reverse polarity protected (RS 422, incremental)
Output frequencymax. 200 kHz
Rise time600 ns
De-energized delay600 ns
Connection
Connectortype 9416 (M23), 12-pin, type 9416L (M23), 12-pin
Cable∅6.5 mm, 4 x 2 x 0.14 mm2, 1 m
Standard conformity
Degree of protectionDIN EN 60529, IP65
Climatic testingDIN EN 60068-2-78
Emitted interferenceEN IEC 61000-6-4:2019
Noise immunityEN IEC 61000-6-2:2019
Shock resistanceDIN EN 60068-2-27, 100 g, 6 ms
Vibration resistanceDIN EN 60068-2-6, 10 g, 10 ... 2000 Hz
Approvals and certificates
UL approvalE223176 , cULus Listed, General Purpose, Class 2 Power Source
Maximum permissible ambient temperaturemax. 60 °C (max. 140 °F)
Ambient conditions
Operating temperature-5 ... 70 °C (23 ... 158 °F) , cable, movable installation
-20 ... 70 °C (-4 ... 158 °F), cable, fixed installation
Storage temperature-40 ... 80 °C (-40 ... 176 °F)
Mechanical specifications
Material
Housingaluminum, blank
Flange3.1645 aluminum
ShaftStainless steel 1.4305 / AISI 303
With insulating sleeve provided as an option, made from PPS GF40 material with internal diameters of 16 mm, 25 mm, 30 mm, 38 mm, isolation voltage of 3 kV (see type code)
Massapprox. 900 g
Rotational speedmax. 3500 min -1
Starting torque≤ 18 Ncm
Shaft load
Angle offset1 °
Axial offsetmax. 1 mm
Dimensions
Length48.5 mm
Diameter87.1 mm

Classifications

SystemClasscode
ECLASS 13.027270501
ECLASS 12.027270501
ECLASS 11.027270501
ECLASS 10.0.127270501
ECLASS 9.027270501
ECLASS 8.027270501
ECLASS 5.127270501
ETIM 9.0EC001486
ETIM 8.0EC001486
ETIM 7.0EC001486
ETIM 6.0EC001486
ETIM 5.0EC001486
UNSPSC 12.139121527

Details: RHI90N

Product Documentation: RHI90N

Language Selection:
Brief Instructions語言檔案類型檔案尺寸
Instruction leaflet / BeipackzettelALLPDF536 KB

Design / Simulation: RHI90N

Language Selection:
CAD語言檔案類型檔案尺寸
CAD 3-D / CAD 3-DALLSTP181 KB
CAD 3-D additional / CAD 3-D additionalALLSTP184 KB
CAD Portal / CAD PortalALLLINK---
CAD Portal / CAD PortalALLLINK---

Approvals: RHI90N

Language Selection:
Certificates證書號碼語言檔案類型檔案尺寸
Canada, USA UL General PurposeUL-US-2233187-0 / UL-CA-2232331-0ALLPDF493 KB
Canada, USA UL General PurposeCoC E223176 RepRef E223176-20050829ALLPDF409 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-2735AALLPDF72 KB

相關產品: RHI90N

Accessories
Female cordsetfa
Female cordsetfa