请注意:所有以Pepperl + Fuchs GmbH或Pepperl + Fuchs AG名义发行的产品相关文件,例如证书,合格声明等,同样适用于Pepperl + Fuchs SE。
產品規格摘要:的技術資料
NDS-F146-8E2-V1
產品描述 |
Inductive transmitter system |
Nominal ratings |
Number of signal channels | 8 |
Signal transfer direction | from secondary side to primary side |
Sensor supply voltage | 12 V ± 10 % , overload and short-circuit resistant |
Ripple | ≤ 5 % |
Transfer power | max. 2.5 W (1.5 W at 5 mm) |
Load step | ≤ 100 mA |
Functional safety related parameters |
MTTFd | 465 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Input |
Number | 8 |
Input type | Input for sensor signals |
Connectable sensor types | DC, 3-wire , PNP ( switched high ) |
Input current | ≤ 1 mA |
Internal resistor | ≥ 15 kΩ |
Compliance with standards and directives |
Directive conformity | |
| EMC Directive 89/336/EEC | EN 61000-6-2:2001, EN 61000-6-4:2001, EN 50295:1999 |
Standard conformity | |
| Standards | EN IEC 60947-5-2 |
Approvals and certificates |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Ambient temperature | 0 ... 50 °C (32 ... 122 °F) |
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
Mechanical specifications |
Degree of protection | IP65 |
Material | |
| Housing | PA 66-FR |
Installation | screw mounting |
Mass | 140 g |
General information |
Note | Maximum cable length between WIS module and WIS transmitter must not exceed 5 m. |
Classifications
System | Classcode |
ECLASS 13.0 | 27274090 |
ECLASS 12.0 | 27274090 |
ECLASS 11.0 | 27270190 |
ECLASS 10.0.1 | 27270190 |
ECLASS 9.0 | 27270190 |
ECLASS 8.0 | 27270190 |
ECLASS 5.1 | 27270190 |
ETIM 9.0 | EC002714 |
ETIM 8.0 | EC002714 |
ETIM 7.0 | EC002714 |
ETIM 6.0 | EC002714 |
ETIM 5.0 | EC002714 |
UNSPSC 12.1 | 39121550 |
Details:
NDS-F146-8E2-V1
Product Documentation:
NDS-F146-8E2-V1
Design / Simulation:
NDS-F146-8E2-V1
相關產品:
NDS-F146-8E2-V1
Matching System Components |
|
|
|
fa |
|
|
|
|
fa |
|
Matching System Components |
|
|
|
fa |
|
|
|
|
fa |
|