工業感測器服務資訊
+886 2 27227708
+886-2-27227782
防爆產品服務資訊

Control Stations Division 2, Stainless Steel SR.CS2*

SR.CS2*
  • For use in North America
  • Stainless Steel enclosure
  • Certified for Class I, Division 2 hazardous areas
  • Up to 107 operators per control station
  • 10 enclosure size options
  • Return Flange Sealing provides Drain Channel
  • Customizable configuration of operators, cable entry quantities and cable gland types as per specification
  • Customizable configuration of gland plates, ground bolt and hinges as per specification
  • Option for vertical or horizontal mounting provides high flexibility
  • Up to 4 gland plates
  • Wide range of labels and accessories available

请注意:所有以Pepperl + Fuchs GmbH或Pepperl + Fuchs AG名义发行的产品相关文件,例如证书,合格声明等,同样适用于Pepperl + Fuchs SE。

將完整的規格書下載為PDF:


產品規格摘要:的技術資料  SR.CS2*

產品描述
Control Stations Division 2, Stainless Steel
Electrical specifications
Operating voltage250 V AC max.
Operating current5 A max.
Terminal capacity2.5 mm2
Terminal torque0.8 Nm ... 1.2 Nm
Mechanical specifications
Enclosure coverfully detachable , hinged
Cover fixingstainless steel A4 (V4A) hexagonal head screws , see data table
Cover sealsilicone
Degree of protectionType 4X
Cable entrycable glands as per specification
Gland plate on face(s)optional
Material
Enclosure1.5 mm AISI 316L, (1.4404) stainless steel
Gland plateoptional 3 mm or 6 mm AISI 316L (1.4404) stainless steel
Finishbrushed
Masssee data table
valid for empty enclosure, will increase according to integrated components
Dimensionssee data table
Mountingscrews , optional mounting brackets enclosed
GroundingM6 internal/external brass nickel-plated grounding bolt
M6 internal stainless steel grounding bolt welded to lid
M6 internal stainless steel grounding bolt welded to enclosure body
Ambient conditions
Ambient temperature-40 ... 55 °C (-40 ... 131 °F) depending on integrated components
International approvals
ETL approval
ETL certificateIntertek 5003368 , Intertek 5022079
Approved forClass I, Division 2, Groups A, B, C, D
cETLusaccording to UL 508A , UL 121201 , CSA C22.2, No. 213, 286
Ambient temperature-25 ... 40 °C (-13 ... 104 °F) T6
-40 ... 55 °C (-40 ... 131 °F) T5
Conformity
Degree of protectionUL 50 / UL 50E
General information
Ordering informationThis device will be delivered completely configured and assembled ready for use. For configuration details please contact Customer Service.
Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Accessories
Optional accessoriesMounting plate
M6 internal/external stainless steel grounding bolt
gland plate 3 mm AISI 316L (1.4404) stainless steel
gland plate 6 mm AISI 316L (1.4404) stainless steel
M6 internal stainless steel grounding bolt welded to bottom gland plate
quarter-turn key locks stainless steel A4 (V4A)
engraved traffolyte tag label
engraved AISI 316L stainless steel tag label
color in-fill stainless steel tag label
cover padlock facility
Indicators/operating means
Control elementssmall footprint max. 107 see data table
all NC contacts have a direct opening action for emergency stop functions

Classifications

SystemClasscode
ECLASS 13.027180502
ECLASS 12.027180502
ECLASS 11.027180502
ECLASS 10.0.127180502
ECLASS 9.027180502
ECLASS 8.027149144
ECLASS 5.127180502
ETIM 9.0EC002503
ETIM 8.0EC002503
ETIM 7.0EC002503
ETIM 6.0EC002503
ETIM 5.0EC002503
UNSPSC 12.139121314

Details: SR.CS2*

Product Documentation: SR.CS2*

Language Selection:
Brief Instructions語言檔案類型檔案尺寸
Brief Instructions - Control Stations SR.CS2* Class I, Division 2ENGPDF286 KB
Instruction leaflet / BeipackzettelALLPDF142 KB

Approvals: SR.CS2*

Language Selection:
Certificates證書號碼語言檔案類型檔案尺寸
Hazardous Location103993313DAL-003ALLPDF133 KB
SR Series—Stainless Steel Enclosures for Hazardous Areas

The new SR enclosure series made of stainless steel impresses with its modular concept: Discover the range of enclosures that perfectly solves every application—at every level …