General specifications |
Measuring range | 0.1 … 20 m (black 10 %) 0.1 … 60 m (white 90 %) 0.1 … 60 m (reflector) Min. reflectivity 1.8 % |
Light source | laser diode |
Light type | modulated infrared light |
Laser nominal ratings | |
| Note | LASER RADIATION , DO NOT STARE INTO BEAM |
| Laser class | 1 |
| Wave length | 905 nm |
| Beam divergence | transversal 2 mrad , longitudinal 10 mrad |
| Pulse length | 5 ns |
| Repetition rate | 54 kHz |
| max. pulse energy | < 94 nJ |
Measuring method | Pulse Ranging Technology (PRT) |
Scan rate | 10 Hz, 20 Hz, 30 Hz |
Scanning angle | 360° |
Diameter of the light spot | 25 mm x 105 mm at 10 m |
Ambient light limit | 50000 Lux |
Functional safety related parameters |
MTTFd | 75 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means |
Operation indicator | LED green |
Data flow indicator | LED yellow: active ethernet LED green: Ethernet link |
Function indicator | LED red: fault LED yellow: Q1 + Q2 |
Control elements | 2 Button |
Parameterization indicator | 24 x 252 pixels , red |
Electrical specifications |
Operating voltage | 10 ... 30 V DC |
Ripple | 10 % within the supply tolerance |
No-load supply current | ≤ 400 mA / 24 V DC |
Power consumption | < 10 W |
Time delay before availability | < 40 s |
Integrated application |
Application | Field monitoring |
Number of fields | 4 |
Response time | 30 ms + 1 Scan duration |
Detectable object shape | Almost any |
Object size | > 1 mm |
Linking fields | Up to 4 x 3 levels |
Interface |
Interface type | 4 x switching inputs/outputs (selectable) |
Input/Output |
Input/output type | 4 Inputs/Outputs , Independently configurable , short circuit/reverse polarity protected |
Input |
Switching threshold | low: Ue < 5 V, high: Ue > 10 V |
Output |
Switching threshold | low: Ua < 1 V, high: Ua > Ub - 2 V |
Switching current | 100 mA per output |
Conformity |
Laser safety | EN 60825-1:2014 |
Compliance with standards and directives |
Standard conformity | |
| Product standard | IEC 61000-6-2 |
| Shock and impact resistance | EN 60068-2-6 EN 60068-2-27 |
Measurement accuracy |
Measuring speed | 54000 measurements per second |
Angle resolution | 0,071°; 0,15°; 0,2° |
Repeat accuracy | < 12 mm |
Approvals and certificates |
Protection class | III (operating voltage 50 V) |
UL approval | cULus Listed, Class 2 Power Source, Type 1 enclosure |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Ambient temperature | -30 ... 50 °C (-22 ... 122 °F) |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) |
Relative humidity | 95 % , no moisture condensation |
Mechanical specifications |
Degree of protection | IP67 |
Connection | 4-pin, M12x1 connector, standard (supply) , 8-pin, M12x1 connector, A-coded (MultiPort) , 4-pin, M12x1 socket, D-coded (LAN) |
Material | |
| Housing | ABS + PC + Aluminum |
| Optical face | PMMA |
Mass | approx. 0.8 kg |
Dimensions | |
| Height | 116.5 mm |
| Width | 106 mm |
| Length | 106 mm |