產品規格摘要:的技術資料
F*-LBF-D1.32
產品描述 |
Surge protector, threaded, for installation via threaded inlet in field housing (Ex d), IP67 |
General specifications |
Design / Mounting | Outside installation |
Installation in hazardous area | Zone 1 |
Electrical specifications |
Rated voltage | 32 V |
Nominal discharge current (8/20 µs) | |
| per line | 10 kA |
| total | 10 kA |
Max. surge current (8/20 µs) | 10 kA |
Voltage protection level at max. rated current | |
| Line/Line | 58 V |
| Line/Earth | 1700 V |
Voltage protection level at 1 kV/µsec | |
| Line/Line | 50 V |
| Line/Earth | 1.2 kV |
Reaction time | |
| Line/Line | max. 1 ns |
| Line/Earth | max. 100 ns |
Capacitance | |
| Line/Line | 25 pF |
| Line/Earth | 15 pF |
Directive conformity |
Electromagnetic compatibility | |
| Directive 2014/30/EU | EN 61326-1:2013 |
Standard conformity |
Electromagnetic compatibility | NE 21:2006 |
Degree of protection | IEC/EN 60529 |
Fieldbus standard | IEC 61158-2 |
Surge protection | IEC 61643-21 |
Ambient conditions |
Ambient temperature | -50 ... 80 °C (-58 ... 176 °F) |
Storage temperature | -50 ... 85 °C (-58 ... 185 °F) |
Mechanical specifications |
Core cross section | 1.3 mm2 |
Housing material | Stainless steel 1.4401/316 |
Degree of protection | IP00/IP67 if correctly installed |
Mass | 160 g |
Mounting | screw mounting |
Data for application in connection with hazardous areas |
EU-type examination certificate | KEMA 04 ATEX 2318 X |
| Marking | II 2G Ex d IIC T6...T5 Gb |
Maximum values | |
| Rated voltage | 32 V |
Directive conformity | |
| Directive 2014/34/EU | EN 60079-0:2018 , EN 60079-1:2007 |
International approvals |
IECEx approval | IECEx KEM 09.0067X |
| Approved for | Ex d IIC T6...T5 Gb |
Certificates and approvals |
Marine approval | DNV A-14038 |
General information |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Classifications
System | Classcode |
ECLASS 13.0 | 27242692 |
ECLASS 12.0 | 19170104 |
ECLASS 11.0 | 27242692 |
ECLASS 10.0.1 | 27242692 |
ECLASS 9.0 | 27242692 |
ECLASS 8.0 | 27242692 |
ECLASS 5.1 | 27242692 |
ETIM 9.0 | EC002584 |
ETIM 8.0 | EC002584 |
ETIM 7.0 | EC002584 |
ETIM 6.0 | EC002584 |
ETIM 5.0 | EC001604 |
UNSPSC 12.1 | 39121610 |
Details:
F*-LBF-D1.32
Product Documentation:
F*-LBF-D1.32
Design / Simulation:
F*-LBF-D1.32
相關產品:
F*-LBF-D1.32
Accessory of |
|
|
|
FieldConnex® Fieldbus, Fieldbus barrier, module for DIN rail mounting, 8 ... 12 outputs Ex ia IIC, FISCO and Entity, Advanced fault isolation and diagnostics at the spur, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0...1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Dust protection, International, Europe, USA, Device coupler location: Zone 2 - high-power trunk Zone 1 - high-power trunk Division 2 - high-power trunk Division 1 - high-power trunkpa |
|