请注意:所有以Pepperl + Fuchs GmbH或Pepperl + Fuchs AG名义发行的产品相关文件,例如证书,合格声明等,同样适用于Pepperl + Fuchs SE。
產品規格摘要:的技術資料
F.SP5.T**.***.1.*.***.***.****
產品描述 |
Segment Protector Junction Box, Brushed Stainless Steel |
General specifications |
Design / Mounting | Outside installation |
Installed components | Segment Protector R2-SP-IC* For technical data on installed electronic component see data sheet. |
Conformity |
Degree of protection | EN 60529 |
Impact resistance | EN 60079-0 |
Ambient conditions |
Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) |
Relative humidity | < 75 % (annual mean) < 95 % (30 d/year), no moisture condensation |
Impact resistance | 7J |
Mechanical specifications |
Enclosure cover | Hinged door with captive retaining screws |
Degree of protection | IP66 |
Cable entry | cable gland and stopping plug options see separate table |
Material | |
| Housing | Stainless steel 1.4404 / AISI 316L |
| Surface | brushed |
| Seal | Silicone, fire-resistant, one piece, foamed |
| Material thickness | enclosure body, enclosure cover, mounting plate: 1.5 mm |
Dimensions | (W x H x D) 310 mm x 310 mm x 160 mm (SRM.31.31.16) 380 mm x 380 mm x 220 mm (SRM.38.38.22) |
Mounting | thru-holes Ø 7 mm |
Grounding | grounding bolt M6 , brass, nickel-plated |
Data for application in connection with hazardous areas |
Certificate | PTB 17 ATEX 1011 X |
| Marking | II 3G Ex eb nA [ic] IIC T4 Gc II 3D Ex tc [ic] IIIC T135°C Dc |
Directive conformity | |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-1:2014+AC:2018 , EN IEC 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN 60079-18:2015+Cor.2018 , EN 60079-31:2014 |
International approvals |
IECEx approval | IECEx PTB 09.0016 X |
EAC approval | TC RU C-IT.GB05.B.00915 |
General information |
Supplementary information | Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Classifications
System | Classcode |
ECLASS 13.0 | 27242610 |
ECLASS 12.0 | 27242610 |
ECLASS 11.0 | 27242610 |
ECLASS 10.0.1 | 27242610 |
ECLASS 9.0 | 27242610 |
ECLASS 8.0 | 27242610 |
ECLASS 5.1 | 27242601 |
ETIM 9.0 | EC001601 |
ETIM 8.0 | EC001601 |
ETIM 7.0 | EC001601 |
ETIM 6.0 | EC001601 |
ETIM 5.0 | EC001604 |
UNSPSC 12.1 | 39121008 |
Details:
F.SP5.T**.***.1.*.***.***.****
Product Documentation:
F.SP5.T**.***.1.*.***.***.****
相關產品:
F.SP5.T**.***.1.*.***.***.****
Matching System Components |
|
|
|
FieldConnex® Fieldbus, Segment protector, junction box for fieldbus with short-circuit and fault protection, field junction box, electronic component for control cabinet installation, 4 ... 12 outputs Ex ic (FISCO or Entity) or non-incendive (Div 2), Advanced fault isolation at the spur, Segment Protector in Zone 2/Div. 2, Instruments in Zone 2/Div. 2 or Zone 1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, International, Europe, USA, Canadapa |
|
|
|
|
FieldConnex® Fieldbus, Surge protector, pluggable module for trunk installation on segment protector, Pluggable, mounts between device coupler and trunk cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield via gas-discharge tube, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Europe, USA, Canadapa |
|
|
|
|
FieldConnex® Fieldbus, Surge protector, pluggable module for spur installation on segment protector, Pluggable, mounts between device coupler and spur cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield via gas-discharge tube, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Europe, USA, Canadapa |
|