General specifications |
Measuring range | X = 40 ... 310 mm ; Z = 60 ... 700 mm |
Light source | laser diode |
Light type | red laser + Integrated LED lightning red 650 nm |
Laser nominal ratings | |
| Note | VISIBLE LASER RADIATION , DO NOT STARE INTO BEAM DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS |
| Laser class | 1 |
| Wave length | Measuring laser: 660 nm |
| Pulse length | Measuring laser: 2 ms |
| Maximum optical power output | Measuring laser: 15 mW |
| Laser monitoring | The safety system switches off the laser when the laser current is too high |
Object size | > 0.1 mm at min. read distance |
Scan rate | 30 s-1 |
Functional safety related parameters |
MTTFd | 20 a |
Mission Time (TM) | 10 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means |
Operation indicator | LED green |
Diagnostics indicator | LED yellow / red |
Function indicator | Trigger: LED yellow ; object in evaluation range : LED red / green |
Control elements | 2 push-buttons |
Electrical specifications |
Operating voltage | 24 V ± 20 % , PELV |
No-load supply current | max. 250 mA |
Power consumption | max. 6 W , Outputs without load |
Interface |
Interface type | RS 485 interface |
Physical | Switchable terminal resistor |
Protocol | binary code |
Transfer rate | 38400 ... 230400 Bit/s |
Input |
Input voltage | 24 V |
Number/Type | External triggering + 1 Input |
Switching threshold | low: < 2.5 V, high: > 8 V |
Output |
Number/Type | 2 digital outputs |
Switching type | PNP |
Switching voltage | 24 V |
Switching current | 150 mA each output |
Compliance with standards and directives |
Standard conformity | |
| Noise immunity | EN 61000-6-2:2005 |
| Emitted interference | EN 61000-6-4:2007/A1:2011 |
| Degree of protection | EN 60529 |
| Shock and impact resistance | EN 60068-2-27:2009 |
| Laser class | IEC 60825-1:2007 |
Approvals and certificates |
UL approval | cULus Listed, Type 1 enclosure |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Approvals | CE |
Ambient conditions |
Operating temperature | -20 ... 45 °C (-4 ... 113 °F) , (noncondensing; prevent icing on the lens!) |
Storage temperature | -20 ... 70 °C (-4 ... 158 °F) |
Mechanical specifications |
Degree of protection | IP67 |
Connection | 8-pin, M12 x 1 connector ( supply + RS485 + Inputs/Outputs ) ; can be rotated 90° ; Grounding : Grounding clip for PCV system |
Material | |
| Housing | PC/ABS |
| Optical face | Plastic pane |
Mass | approx. 125 g |
Tightening torque, fastening screws | max. 2 Nm |
Dimensions | |
| Height | 85 mm |
| Width | 38 mm |
| Depth | 55 mm |
General information |
Note | Security Instructions: - Read the operating instructions before attempting commissioning - Installation, connection and adjustments should only be undertaken by specialist personnel - Not a safety component in accordance with the EU Machinery Directive |