General specifications |
Light type | Integrated LED lightning (white) |
Polarization filter | yes |
Symbologies | Data Matrix, Code 39, Code 128, Int 2 of 5, EAN13, Pharmacode |
Read distance | 45 ... 90 mm Nominal distance: 70 mm |
Reading field | Minimum read field: 22 mm x 30 mm Read field at nominal distance: 28 mm x 45 mm Maximum read field: 35 mm x 55 mm |
Modul size | Minimum module size: 0.15 mm |
Evaluation frequency | up to 100 Hz |
Target velocity | triggered max. 10 m/s |
Data Matrix | |
| Symbol size | rectangular up to 144 x 144 modules rectangular up to 16 x 48 modules |
| Data format | ASCII, C40, Text, X12, Edifact, Base 256 , all according to ISO 646 |
| Orientation | omnidirectional |
Nominal ratings |
Camera | |
| Type | CMOS , Global shutter |
| Number of pixels | 752 x 480 pixels |
| Gray scale | 256 |
| Image recording | real-time , Program-controlled or triggered externally |
Functional safety related parameters |
MTTFd | 40.5 a |
Mission Time (TM) | 8 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means |
Operation indicator | LED green: Ready for operation |
LED indication | for good/poor reading |
Electrical specifications |
Operating voltage | 24 V DC ± 15% , PELV |
No-load supply current | max. 250 mA |
Power consumption | 6 W |
Interface |
Interface type | serial , RS 232 |
Transfer rate | max. 115.2 kBit/s |
Cable length | max. 30 m |
Interface 1 |
Interface type | Ethernet |
Protocol | TCP/IP |
Transfer rate | 100 MBit/s |
Cable length | max. 30 m |
Input |
Input voltage | to be applied externally 24 V ± 15% PELV |
Number/Type | Trigger |
Input current | approx. 10 mA at 24 V DC |
Switching threshold | low: < 10 V, high: > 15 V |
Cable length | max. 30 m |
Output |
Number/Type | GOOD, BAD, Matchcode |
Switching type | PNP |
Switching voltage | to be applied externally 24 V ± 15 % PELV |
Switching current | 100 mA each output |
Cable length | max. 30 m |
Compliance with standards and directives |
Standard conformity | |
| Noise immunity | EN 61326-1:2006 |
| Emitted interference | EN 61000-6-4:2007/A1:2011 |
| Degree of protection | EN 60529 |
| Photobiological safety | Risk group 1 according to IEC 62471 |
Approvals and certificates |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Approvals | CE |
Ambient conditions |
Ambient temperature | 0 ... 45 °C (32 ... 113 °F) |
Storage temperature | -20 ... 60 °C (-4 ... 140 °F) |
Mechanical specifications |
Degree of protection | IP67 |
Connection | 8-pin, M12x1 connector, standard (supply+IO) , 5-pin, M12x1 socket, standard (RS 232) , 4-pin, M12x1 socket, standard (LAN) |
Material | |
| Housing | PC/ABS |
Installation | 4 x M6 threading |
Mass | approx. 160 g |
Dimensions | |
| Height | 70 mm |
| Width | 70 mm |
| Depth | 53 mm |