General specifications
UL File NumberE360395
MTBF61.4 a
Indicators/operating means
LED indicationsee manual
Electrical specifications
Rated operating voltage5 ... 30 V DC
General informationRedundant power
Nominal voltage24 V DC
Interface
Interface typeSoftware selectable interfaces: RS-232 , RS-422 , RS-485 (2 and 4-wire)
Physical 1 x screw terminal
ProtocolRaw serial
Supported baud rates300 bps to 230Kbps
Interface 1
Interface typeIndustrial Ethernet
Physical 1 x RJ45
ProtocolTCP/IP
Additional protocolsARP, BOOTP, DHCP/RARP, HTTP, HTTPS, SSH, SSL/TLS, ICMP, RFC 1006 (ISO over TCP), SNMP (MIB-II), TCP/IP & UDP socket services, Telnet, and TFTP, and supports IP multicast data transmission
Transfer rate10/100 Mbps
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61000-6-2:2005 , EN 610006-4:2007 , EN 610006-4/A1:2011
RoHSEN IEC 63000:2018
Standard conformity
Degree of protectionNEMA TS2
Electrical safetyCSA C22.2 No. 61010-1-12 / CSA C22.2 No. 61010-1-201
UL 61010-1 / UL 61010-1-201
Emitted interferenceEN 61000-6-4, EN 55032, FCC Part 15 Subpart B, ICES-003, AS/NZS CISPR 32
Noise immunityEN 61000-6-2
Ambient conditions
Ambient temperature-40 ... 75 °C (-40 ... 167 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humiditymax. 95 %
Altitude0 ... 3048 m
Mechanical specifications
Degree of protectionIP20
ConnectionPower Supply: screw terminals
Fieldbus: 1 x RJ45
Inputs/outputs: 9-pin screw terminal block
Material
HousingPolyamide, UL94V-0
Mass113.4g
Dimensions
Height99.1 mm
Width22.9 mm
Length119.3 mm
Construction typeCabinet module
MountingDIN mounting rail

Classifications

SystemClasscode
ECLASS 13.027242608
ECLASS 12.027242608
ECLASS 11.027242608
ECLASS 10.0.127242608
ECLASS 9.027242608
ECLASS 8.027242608
ECLASS 5.127242608
ETIM 9.0EC001597
ETIM 8.0EC001597
ETIM 7.0EC001597
ETIM 6.0EC001597
ETIM 5.0EC001597
UNSPSC 12.132151705

Details: ICDM-RX/TCP-ST/RJ45-DIN

Informative Literature: ICDM-RX/TCP-ST/RJ45-DIN

Language Selection:
Literature語言檔案類型檔案尺寸
Product Information - Serial Gateways - DeviceMaster®ENGPDF1227 KB

Product Documentation: ICDM-RX/TCP-ST/RJ45-DIN

Language Selection:
Manuals語言檔案類型檔案尺寸
ICDM-RX/TCP (DeviceMaster) and ICRPC (RocketPort EXPRESS) Windows Driver Installation manualENGPDF21805 KB
ICDM-RX/TCP Hardware Installation and Configuration GuideENGPDF17301 KB

Design / Simulation: ICDM-RX/TCP-ST/RJ45-DIN

Language Selection:
CAD語言檔案類型檔案尺寸
CAD 3-D / CAD 3-DALLSTP3200 KB

Approvals: ICDM-RX/TCP-ST/RJ45-DIN

Language Selection:
Certificates證書號碼語言檔案類型檔案尺寸
Canada, USA UL ULE360395ALLLINK---
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-4274AALLPDF110 KB
Australia Declaration of ConformityACMA Supplier's declaration of conformityALLPDF302 KB

Software: ICDM-RX/TCP-ST/RJ45-DIN

Language Selection:
Device Description Files/Drivers發布資訊檔案類型檔案尺寸
ICDM-RX/TCP Linux device driver / ICDM-RX/TCP Linux Gerätetreiber2024-08 v8.12ZIP129 KB
ICDM-RX/TCP Windows Device Driver / ICDM-RX/TCP Windows Gerätetreiber2024-01 V4.16ZIP15757 KB
Firmware
ICDM-RX/TCP SocketServer firmware v11.66 / ICDM-RX/TCP SocketServer firmware v11.662024-09 v11.66ZIP681 KB
Software Tools
LCOM Linux utility / LCOM Linux-Dienstprogramm2024-02ZIP25 KB
PortVision DX v6.02 / PortVision DX v6.022020-08ZIP29584 KB

相關產品: ICDM-RX/TCP-ST/RJ45-DIN

Matching System Components
32-channel, 24 V DC supply, HART field device input (revision 5 to 7), RS-485 interface, Up to SIL 3 acc. to IEC/EN 61508pa
16-channel, 24 V DC supply (Power Rail), HART field device input (revision 5 to 7), Up to 15 KFD0-HMS-16 HART MUX secondary modules can be connected, Up to SIL 3 acc. to IEC/EN 61508pa
Accessories
Ethernet bus cable male cordset single-ended RJ45, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Ethernet bus cable male cordset single-ended RJ45, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Ethernet bus cable male cordset single-ended RJ45, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Ethernet bus cable RJ45 to RJ45 PROFINET-coded, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Ethernet bus cable RJ45 to RJ45 PROFINET-coded, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Ethernet bus cable RJ45 to RJ45 PROFINET-coded, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Ethernet bus cable RJ45 to RJ45 PROFINET-coded, 4-pin, PUR cable green, Cat5e, shielded, drag chain suitablefa
Free Download: White Paper on TCP-Based Communication Protocols (PDF)

这份免费的 PDF 白皮书比较了不同的基于TCP标准的通信协议(包括 AMQP、OPC UA、MQTT、REST API),这些协议已成为 IIoT 和工业 4.0 的推动力。立即免费下载!