Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Hent hele databladet som PDF:
Uddrag af datablad: Tekniske data for
AIR30-8-HW-2500-3767/38a/76a
Produkt beskrivelse |
Single-beam light scanners with finely bundled light beam for monitoring main and ancillary closing edges |
General specifications |
Detection range min. | 100 ... 1000 mm |
Detection range max. | 100 ... 2500 mm |
Light source | IRED |
Light type | modulated infrared light |
Black-white difference (6 %/90 %) | ≤ 400 mm at a distance of 2000 mm |
Transmitter frequency | 1800 Hz |
Operating mode | Background evaluation |
Diameter of the light spot | 50 mm at 2000 mm sensor range |
Opening angle | approx. 1.4 ° |
Accessories provided | Mounting frame for sensors in the AIR30 and PROSCAN series (pre-mounted) |
Functional safety related parameters |
MTTFd | 1050 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 90 % |
Indicators/operating means |
Function indicator | LED red: lights up when output is active |
Control elements | Sensing range adjuster, light-on/dark-on changeover switch |
Factory setting | light-on |
Electrical specifications |
Operating voltage | 10 ... 48 V DC / 11 ... 36 V AC |
No-load supply current | 100 mA |
Input |
Test input | emitter deactivation at +UB |
Output |
Switching type | light/dark on, switchable |
Signal output | relay, 1 NO |
Switching voltage | ≤ 50 V AC / 24 V DC |
Switching current | ≤ 200 mA AC / 1 A DC |
Response time | 50 ms |
De-energized delay | approx. 200 ms |
Standard conformity |
Standards | EN 60947-5-2 |
Standards 2 | EN 61000-6-2 without EN 61000-4-5, EN 61000-4-11 |
Standards 3 | EN 61000-6-3 |
Approvals and certificates |
CCC approval | Certified by China Compulsory Certification (CCC) |
Ambient conditions |
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Storage temperature | -20 ... 75 °C (-4 ... 167 °F) |
Mechanical specifications |
Degree of protection | IP52 |
Connection | 5 m fixed cable |
Material | |
| Housing | plastic |
| Optical face | Luran® |
Mass | 50 g |
Dimensions | |
| Height | 45 mm |
| Width | 102 mm |
| Depth | 32 mm |
Classifications
System | Classcode |
ECLASS 13.0 | 27270913 |
ECLASS 12.0 | 27270913 |
ECLASS 11.0 | 27270913 |
ECLASS 10.0.1 | 27270913 |
ECLASS 9.0 | 27270913 |
ECLASS 8.0 | 27270913 |
ECLASS 5.1 | 27270903 |
ETIM 9.0 | EC002550 |
ETIM 8.0 | EC002550 |
ETIM 7.0 | EC002550 |
ETIM 6.0 | EC002550 |
ETIM 5.0 | EC001821 |
UNSPSC 12.1 | 39121528 |
Details:
AIR30-8-HW-2500-3767/38a/76a
Product Documentation:
AIR30-8-HW-2500-3767/38a/76a
Design / Simulation:
AIR30-8-HW-2500-3767/38a/76a
Approvals:
AIR30-8-HW-2500-3767/38a/76a
Tilhørende produkter:
AIR30-8-HW-2500-3767/38a/76a
Accessories |
|
|
|
Mounting frame for sensors in the AIR30 and PROSCAN seriesfa |
|
|
|
|
Frame for mounting AIR30 sensors in suspended ceilings, Material: plasticfa |
|
|
|
|
Protection from adverse effects of weather such as rain, snow, etc., Material: black ABSfa |
|