Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Hent hele databladet som PDF:
Uddrag af datablad: Tekniske data for
RMS-G-RC
Produkt beskrivelse |
Premium industrial door opener with the ability to differentiate between people and vehicles, can be operated remotely, detection range 7 m x 6 m, max. installation height 7 m, black housing, 2 relay contact outputs, cable connection |
General specifications |
Sensing range | 7000 x 6000 mm (DxW) at 5000 mm mounting height and 30° inclination angle 8000 x 5000 mm (DxW) at 7000 mm mounting height and 30° inclination angle |
Function principle | Microwave module |
Detection speed | min. 0.1 m/s , max. ... 5 m/s (18 km/h) |
Marking | CE, FCC |
Setting angle | 0 ... 40 ° in 5 ° increments |
Operating frequency | 24.15 ... 24.25 GHz K-Band |
Operating mode | Radar motion sensor |
Transmitter radiated power (EIRP) | < 13 dBm |
Functional safety related parameters |
MTTFd | 620 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means |
Function indicator | LED red/green |
Control elements | Programming push-button for selection of operating modes : direction detection , cross-traffic suppression , Vehicle detection , Switching type , relay hold time |
Control elements | Programming via 2 keys , alternative via remote control (Accessories ordered separately) |
Electrical specifications |
Operating voltage | 12 ... 36 V DC , 12 ... 28 V AC |
No-load supply current | ≤ 50 mA at 24 V DC |
Power consumption | ≤ 1 W |
Output |
Switching type | NO/NC |
Signal output | 2 relay outputs |
Switching voltage | max. 48 V AC / 48 V DC |
Switching current | max. 0.5 A AC / 1 A DC |
Switching power | max. 24 W / 60 VA |
De-energized delay | 0.2 ... 5 s adjustable |
Approvals and certificates |
CE conformity | 2014/53/EU This device can be used in all countries within the EU including the United Kingdom. In other countries, all applicable national regulations must be observed. |
EAC conformity | TR CU 020/2011 |
FCC approval | FCC Rules part 15 / This device can be used in the USA. RSS-310 of Industry Canada / This device can be used in Canada. |
Ambient conditions |
Operating temperature | -30 ... 60 °C (-22 ... 140 °F) |
Storage temperature | -30 ... 60 °C (-22 ... 140 °F) |
Relative humidity | max. 90 % non-condensing |
Mechanical specifications |
Mounting height | max. 7000 mm |
Degree of protection | IP54 |
Connection | plug-in screw terminals 4-pin and 2-pin , 8 m connecting cable included with delivery |
Material | |
| Housing | ABS, anthracite |
Mass | 120 g |
Dimensions | 123 mm x 65 mm x 57 mm |
| Height | 65 mm |
| Width | 123 mm |
| Depth | 57 mm |
Suitable series |
Series | RMS |
Classifications
System | Classcode |
ECLASS 13.0 | 27274501 |
ECLASS 12.0 | 27280890 |
ECLASS 11.0 | 27280890 |
ECLASS 10.0.1 | 27280890 |
ECLASS 9.0 | 27280890 |
ECLASS 8.0 | 27280890 |
ECLASS 5.1 | 27270990 |
ETIM 9.0 | EC004807 |
ETIM 8.0 | EC000138 |
ETIM 7.0 | EC000138 |
ETIM 6.0 | EC000138 |
ETIM 5.0 | EC000138 |
UNSPSC 12.1 | 39121528 |
Details:
RMS-G-RC
Product Documentation:
RMS-G-RC
Design / Simulation:
RMS-G-RC
Tilhørende produkter:
RMS-G-RC
Accessories |
|
|
|
Roof mounting- weather cap set for simple mounting on roofs and exposed positions, Protection from adverse effects of weather such as rain, snow, etc., Installation without toolsfa |
|