MLV41-54-G/25/123/124/136
Produkt beskrivelse |
Robust retroreflective sensor for glass detection, compact housing design, 5.2 m detection range, red light, light on, 2 push-pull outputs, M12 plug |
General specifications |
Effective detection range | 0 ... 4 m in TEACH mode 0 ... 5.2 m at switch position "N" |
Reflector distance | 0 ... 4 m in TEACH mode 0 ... 5.2 m at switch position "N" |
Threshold detection range | 6.5 m
|
Reference target | H85-2 reflector |
Light source | LED |
Light type | modulated visible red light , 660 nm |
Polarization filter | yes |
Angle deviation | max. ± 1° |
Diameter of the light spot | approx. 100 mm at detection range 4 m |
Opening angle | 1.5 ° |
Ambient light limit | 40000 Lux |
Functional safety related parameters |
MTTFd | 900 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means |
Operation indicator | LED green, statically lit Power on , Undervoltage indicator: Green LED, pulsing (approx. 0.8 Hz) , short-circuit : LED green flashing (approx. 4 Hz) |
Function indicator | 2 LEDs yellow for switching state, operating reserve, Teach-In and contrast detection mode |
Control elements | 5-step switch for setting the contrast detection levels.
|
Contrast detection levels | 10 % - clean, water filled PET bottles 18 % - clear glass bottles 40 % - colored glass or opaque materials adjustable due to Teach-In switch |
Electrical specifications |
Operating voltage | 10 ... 30 V DC |
Ripple | max. 10 % |
No-load supply current | max. 35 mA |
Input |
Function input | Ext. Teach-In input (ET) |
Output |
Signal output | 2 push-pull (4 in 1) outputs, complementary, short-circuit proof, reverse polarity protected |
Switching voltage | max. 30 V DC |
Switching current | max. 100 mA |
Voltage drop | ≤ 2.5 V DC |
Switching frequency | 1000 Hz |
Response time | 0.5 ms |
Conformity |
Product standard | EN 60947-5-2 |
Approvals and certificates |
Protection class | II, rated voltage ≤ 50 V AC with pollution degree 1-2 according to IEC 60664-1 , functional insulation acc. to DIN EN 50178 |
UL approval | cULus Listed 57M3 (Only in association with UL Class 2 power supply; Type 1 enclosure) |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) |
Storage temperature | -40 ... 75 °C (-40 ... 167 °F) |
Mechanical specifications |
Degree of protection | IP67 |
Connection | 5-pin, M12 x 1 connector |
Material | |
| Housing | Aluminum , Delta-Seal coated |
| Optical face | glass pane |
| Connector | metal |
Mass | 50 g |
Dimensions | |
| Height | 56.5 mm |
| Width | 31 mm |
| Depth | 13.6 mm |
Classifications
System | Classcode |
ECLASS 13.0 | 27270902 |
ECLASS 12.0 | 27270902 |
ECLASS 11.0 | 27270902 |
ECLASS 10.0.1 | 27270902 |
ECLASS 9.0 | 27270902 |
ECLASS 8.0 | 27270902 |
ECLASS 5.1 | 27270902 |
ETIM 9.0 | EC002717 |
ETIM 8.0 | EC002717 |
ETIM 7.0 | EC002717 |
ETIM 6.0 | EC002717 |
ETIM 5.0 | EC002717 |
UNSPSC 12.1 | 39121528 |
Details:
MLV41-54-G/25/123/124/136
Product Documentation:
MLV41-54-G/25/123/124/136
Design / Simulation:
MLV41-54-G/25/123/124/136
Approvals:
MLV41-54-G/25/123/124/136
Tilhørende produkter:
MLV41-54-G/25/123/124/136
Accessories |
|
|
|
Female cordset single-ended M12 straight A-coded, 5-pin, PUR cable greyfa |
|
|
|
|
Mounting bracket for Sensors series MLV41 for M12 rod mountingfa |
|
|
|
|
Reflector, rectangular 84.5 mm x 84.5 mm, mounting holesfa |
|
|
|
|
Reflector, rectangular 51 mm x 61 mm, mounting holes, fixing strapfa |
|
|
|
|
Reflector, rectangular 60 mm x 19 mm, mounting holesfa |
|
|
|
|
Reflector, rectangular 50.9 mm x 60.9 mm, mounting holes, fixing strap and polarization filterfa |
|
|
|
|
Reflective tape 100 mm x 100 mmfa |
|