Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Hent hele databladet som PDF:
Uddrag af datablad: Tekniske data for
NCN25-F35-A2-250-V1
General specifications |
Switching function | complementary |
Output type | PNP |
Rated operating distance | 25 mm |
Installation | flush mountable |
Output polarity | DC |
Assured operating distance | 0 ... 20 mm |
Reduction factor rAl | 0.5 |
Reduction factor rCu | 0.5 |
Reduction factor r304 | 0.6 ... 1 |
Output type | 4-wire |
Mounting angle | Al |
Amplifier housing | Stainless steel |
Nominal ratings |
Operating voltage | 10 ... 30 V |
Switching frequency | 0 ... 20 Hz |
Hysteresis | 0.3 ... 5 typ. 2 % |
Reverse polarity protection | reverse polarity protected |
Short-circuit protection | pulsing |
Voltage drop | ≤ 3 V |
Operating current | 0 ... 200 mA |
No-load supply current | ≤ 25 mA |
Time delay before availability | ≤ 20 ms |
Switching state indicator | Multihole-LED, yellow |
Functional safety related parameters |
MTTFd | 7515 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Compliance with standards and directives |
Standard conformity | |
| Standards | EN IEC 60947-5-2 |
Approvals and certificates |
UL approval | cULus Listed, General Purpose, Class 2 Power Source |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Ambient temperature | 0 ... 250 °C (32 ... 482 °F) |
Mechanical specifications |
Connection type | Connector plug M12 x 1 , 4-pin |
Cable version | PFA cable, with armour of stainless steel |
Core cross section | 3 x 0.34 , screened |
Housing material | PTFE / Al / 1.4305 / AISI 303 |
Sensing face | PTFE |
Degree of protection | amplifier IP67 sensor IP40 |
Dimensions | |
| Height | 40 mm |
| Width | 44 mm |
| Length | 56 mm |
Cable length | L = 10 m |
Note | - amplifier 0 °C ... 70 °C - r1.4305 dep. on thickness of measurement plate d: r1.4305 = 1 for d < 1mm Additional accessory: Protective cover SH-F35 is available for use in areas where there is moisture and as a means of mechanical protection. |
Classifications
System | Classcode |
ECLASS 13.0 | 27274001 |
ECLASS 12.0 | 27274001 |
ECLASS 11.0 | 27270101 |
ECLASS 10.0.1 | 27270101 |
ECLASS 9.0 | 27270101 |
ECLASS 8.0 | 27270101 |
ECLASS 5.1 | 27270101 |
ETIM 9.0 | EC002714 |
ETIM 8.0 | EC002714 |
ETIM 7.0 | EC002714 |
ETIM 6.0 | EC002714 |
ETIM 5.0 | EC002714 |
UNSPSC 12.1 | 39121550 |
Details:
NCN25-F35-A2-250-V1
Design / Simulation:
NCN25-F35-A2-250-V1
Approvals:
NCN25-F35-A2-250-V1
Tilhørende produkter:
NCN25-F35-A2-250-V1
Accessories |
|
|
|
Female cordset single-ended M12 angled A-coded, 4-pin, PUR cable greyfa |
|
|
|
|
Female cordset single-ended M12 straight A-coded, 4-pin, PUR cable greyfa |
|
|
|
|
Mounting flange, 18 mm, Retainer for all cylindrical sensors with M18 thread, Simple installation and exact setting, Large sensing range (max. 20 mm)fa |
|
|
|
|
fa |
|