Inductive sensor NEN40-30GM60-E0

NEN40-30GM60-E0
  • 40 mm non-flush
  • Increased operating distance

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Hent hele databladet som PDF:


Uddrag af datablad: Tekniske data for   NEN40-30GM60-E0

General specifications
Switching functionNormally open (NO)
Output typeNPN
Rated operating distance40 mm
Installationnon-flush
Output polarityDC
Assured operating distance0 ... 32.4 mm
Reduction factor rAl 0.42
Reduction factor rCu 0.37
Reduction factor r304 0.78
Output type3-wire
Nominal ratings
Installation conditions
Ain aluminum: 25 mm
in steel 1.0037 (St37): 35 mm
in brass 25 mm
in stainless steel 20 mm
B55 mm
C120 mm
F150 mm
Operating voltage10 ... 30 V
Switching frequency0 ... 100 Hz
Hysteresis≤ 10 %
Reverse polarity protectionreverse polarity protected
Short-circuit protectionpulsing
Voltage drop≤ 2 V
Operating current0 ... 200 mA
Off-state current0 ... 0.1 mA typ. 0.1 µA at 25 °C
No-load supply current≤ 10 mA
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd211 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
StandardsEN IEC 60947-5-2
Approvals and certificates
CCC approvalCCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection typecable PVC , 2 m
Core cross section0.34 mm2
Housing materialchromium plated brass
Sensing facePBT
Degree of protectionIP67
Dimensions
Length60 mm
Diameter30 mm

Classifications

SystemClasscode
ECLASS 13.027274001
ECLASS 12.027274001
ECLASS 11.027270101
ECLASS 10.0.127270101
ECLASS 9.027270101
ECLASS 8.027270101
ECLASS 5.127270101
ETIM 9.0EC002714
ETIM 8.0EC002714
ETIM 7.0EC002714
ETIM 6.0EC002714
ETIM 5.0EC002714
UNSPSC 12.139121550

Details: NEN40-30GM60-E0

Design / Simulation: NEN40-30GM60-E0

Language Selection:
CADSprogFil typeFil størrelse
CAD 3-D / CAD 3-DALLSTP40 KB
CAD Portal / CAD PortalALLLINK---
CAE
CAE EPLAN Data Portal / CAE EPLAN Data PortalALLLINK---
EPLAN macro EDZ / EPLAN Makro EDZALLEDZ64 KB

Approvals: NEN40-30GM60-E0

Language Selection:
CertificatesCertifikat nr.SprogFil typeFil størrelse
China Information on CCCCCC-Exempt Declaration (Pepperl+Fuchs)ALLPDF457 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-3027BALLPDF1218 KB
UK Declaration of Conformity (P+F)TDOC-6087_ENGENGPDF1285 KB

Tilhørende produkter: NEN40-30GM60-E0

Accessories

Mounting flange, 30 mmfa

Our amplify article gives interesting insights about the development of the new, modern portfolio of inductive proximity sensors from Pepperl+Fuchs. Get the whole story here! 

 

 

Knowledge Base for Inductive Sensors

The knowledge base for inductive sensors contains extensive expertise and supports you in the highly precise and smooth operation of the sensors in your machinery and plants.

VariKont with Active Shielding Technology

The VariKont inductive sensors with Active Shielding Technology ensure high switching distances, no matter the installation situation and the surrounding material. Benefit from easier equipment design and reduced costs!

Inductive Safety Sensors SIL 2 PL d

As the SIL 2/PL d inductive safety sensors have no dead band, data transfer can occur with no minimum distance between sensor and target. Discover the optimized portfolio for demanding environments.