Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Hent hele databladet som PDF:
Uddrag af datablad: Tekniske data for
WCS3B-LS510-OM
Produkt beskrivelse |
Reader with protective enclosure, EtherNet/IP interface |
General specifications |
Passage speed | ≤ 12.5 m/s |
Measuring length | max. 314.5 m |
Free tolerances to code rail | horizontal: 28 mm ( ± 14 mm ) vertical: 25.5 mm ( +11.5 mm/-14 mm ) |
Resolution | ± 0.4 mm (1,250 positions/m) |
Functional safety related parameters |
MTTFd | 172 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means |
LED green | ETHERNET link To: ETHERNET connection OK |
LED yellow | ETHERNET Bus Activity Flashing: data transfer |
LED red | ETHERNET communication To: communication error |
LED red/green | Status indication Green: code rail detected, normal function Red: system error Flashing red: no code rail detected |
Electrical specifications |
Operating voltage | 10 ... 30 V DC |
Power consumption | 6 W |
Interface |
Interface type | 100 BASE-TX |
Data output code | binary code |
Protocol | EtherNet/IP
|
Transfer rate | 100 MBit/s |
Standard conformity |
Emitted interference | EN 61000-6-4:2007+A1:2011 |
Noise immunity | EN 61000-6-2:2005 |
Shock resistance | EN 60068-2-27:2009 |
Vibration resistance | EN 60068-2-6:2008 |
Approvals and certificates |
CSA approval | cCSAus Certified, General Purpose Class 2 power source |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Operating temperature | 0 ... 60 °C (32 ... 140 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications |
Connection type | 8-pin, M12 x 1 connector socket, Y-coded |
Degree of protection | IP67 / IP69 |
Material | |
| Housing | PET , PC (Polycarbonate) |
Mass | 1000 g |
Note | The reader must not be operated without the protective housing! |
Classifications
System | Classcode |
ECLASS 13.0 | 27270918 |
ECLASS 12.0 | 27270918 |
ECLASS 11.0 | 27270701 |
ECLASS 10.0.1 | 27270701 |
ECLASS 9.0 | 27270701 |
ECLASS 8.0 | 27270701 |
ECLASS 5.1 | 27270701 |
ETIM 9.0 | EC001852 |
ETIM 8.0 | EC001852 |
ETIM 7.0 | EC001852 |
ETIM 6.0 | EC001852 |
ETIM 5.0 | EC001852 |
UNSPSC 12.1 | 41111945 |
Details:
WCS3B-LS510-OM
Product Documentation:
WCS3B-LS510-OM
Design / Simulation:
WCS3B-LS510-OM
Approvals:
WCS3B-LS510-OM
Software:
WCS3B-LS510-OM
Device Description Files/Drivers | Udgivelses info | Fil type | Fil størrelse |
EDS / EDS | | ZIP | 7 KB
|
Tilhørende produkter:
WCS3B-LS510-OM
Accessory of |
|
|
|
WCS3 guiding trolley for the WCS3B read head with protective enclosure, outdoor use, Ensures the optimum alignment of reading head and code rail, Plastic rollersfa |
|
Accessories |
|
|
|
Outdoor protective cover for WCS3B reader, Accessory WCS3Bfa |
|
|
|
|
Male connector RJ45 straight 4-pin, Cat5, shielded, field-attachable, insulation displacement connection, Outdoorfa |
|
|
|
|
Male connector M12 angled A-coded 5-pin, for cable diameter 5 - 8 mm, shielded, field-attachablefa |
|
|
|
|
Male connector M12 straight A-coded 5-pin, for cable diameter 5 - 8 mm, shielded, field-attachablefa |
|
|
|
|
Stopping plugs For WCS32B-OP* housing, Accessory WCS3Bfa |
|
|
|
|
Y-Splitter M12 plug 8-pin Y-coded to M12 socket 4-pin D-coded / M12 plug 4-pin A-codedfa |
|