Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Hent hele databladet som PDF:
Uddrag af datablad: Tekniske data for
PUS-F161-B31-WCS
Produkt beskrivelse |
Safe evaluation unit for position and speed monitoring for WCS read heads; EtherCAT with FSoE protocol |
Functional safety related parameters |
Safety Integrity Level (SIL) | SIL 3 |
Performance level (PL) | PL e |
Category | Cat. 4 |
Mission Time (TM) | 20 a |
PFH | 12.6 E-9 |
Supply |
Rated voltage | 24 V DC |
Rated current | 2 A |
Power consumption | ≤ 6.8 W |
Indicators/operating means |
LED indication | see manual |
Interface |
Protocol | EtherCAT® , FailSafe over EtherCAT® (FSoE) |
Input |
Number | 14 |
Input type | safe digital inputs |
Input current | 20 mA Type 1 according to IEC 61131-2 |
Output |
Number | pp-switching: 4 (configurable via SafePLC) pn-switching: 2 (configurable via SafePLC) |
Number/Type | 2x Relay output 2x Auxiliary output 250 mA 2x Pulse output (clock output) 250 mA |
Output type | safe digital outputs |
Switching current | 2 A |
Ambient conditions |
Ambient temperature | 0 ... 50 °C (32 ... 122 °F) |
Storage temperature | -25 ... 70 °C (-13 ... 158 °F) |
Relative humidity | 5 % - 85 % |
Altitude | max. 2000 m |
Mechanical specifications |
Connection type | Inputs/Outputs screw terminals pluggable Ethernet RJ45 Read head RS-485 |
Degree of protection | IP20 |
Connection | at screw terminals min. Connection cross section : 0,2 mm2 / 24 AWG max. Connection cross section : 2.5 mm2 / 12 AWG |
Mass | 490 g |
Dimensions | |
| Height | 100 mm |
| Width | 90 mm |
| Length | 115 mm |
Mounting | DIN mounting rail |
Classifications
System | Classcode |
ECLASS 13.0 | 27270991 |
ECLASS 12.0 | 27270991 |
ECLASS 11.0 | 27270791 |
ECLASS 10.0.1 | 27270791 |
ECLASS 9.0 | 27270791 |
ECLASS 8.0 | 27270791 |
ECLASS 5.1 | 27270791 |
ETIM 9.0 | EC001852 |
ETIM 8.0 | EC001852 |
ETIM 7.0 | EC001852 |
ETIM 6.0 | EC001852 |
ETIM 5.0 | EC001852 |
UNSPSC 12.1 | 41111945 |
Details:
PUS-F161-B31-WCS
Product Documentation:
PUS-F161-B31-WCS
Approvals:
PUS-F161-B31-WCS
Software:
PUS-F161-B31-WCS
Tilhørende produkter:
PUS-F161-B31-WCS
Kit |
|
|
|
Kit consisting of a safe evaluation unit with fieldbus connection (EtherCAT® with FSoE protocol) and two safeWCS/PUS read heads, FailSafe over EtherCAT® (FSoE), Certified up to SIL 3 according to IEC 61508 and up to PLe according to EN 13849-1, Safe evaluation unit with WCS3B-LS221-U1 and WCS3B-LS221-U2, Reliable evaluation of position and speedfa |
|
Accessories |
|
|
|
License dongle for safeControl Expertfa |
|
|
|
|
Parameterization adapter for parameterization and analysis of the PUS evaluation unitfa |
|
|
|
|
DeviceNet/CANOpen bus cable M12 socket straight A-coded 4-pin to M12 plug straight A-coded 8-pin, PUR cable 4-core twisted pairs black, shielded, UL approved, drag chain suitable, outdoorfa |
|