1-channel signal conditioner, 24 V DC supply, Input 2-wire and 3-wire SMART transmitters and current sources, Output 0/4 mA ... 20 mA, Accuracy 0.1 %, Connection via screw terminals, Number of channels: 1-channel, HART communication, Signal type: Analog input, Rated voltage: 16.8 ... 31.2 V DC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current source, Signal: 0/4 ... 20 mA, Signal: 1 x 0/4 ... 20 mApa

1-channel signal conditioner, 24 V DC supply, Input 2-wire and 3-wire transmitters and 2-wire current sources, Current and voltage output, Accuracy 0.1 %, Configurable by DIP switches, Connection via screw terminals, Number of channels: 1-channel, Signal type: Analog input, Rated voltage: 16.8 ... 31.2 V DC, Field device: 2-wire transmitter, Field device [2]: 3-wire transmitter, Field device [3]: current source, Signal: 0/4 ... 20 mA, Signal: 1 x 0/4 ... 20 mA, Signal [2]: 1 x 0/2 ... 10 Vpa

1-channel signal conditioner, 24 V DC supply, Input current and voltage sources, Current and voltage output, Accuracy 0.1 %, Configurable by DIP switches, Connection via screw terminals, Number of channels: 1-channel, Signal type: Analog input, Rated voltage: 16.8 ... 31.2 V DC, Signal: 0/4 ... 20 mA, Signal [2]: 0/2 ... 10 V, Signal: 1 x 0/4 ... 20 mA, Signal [2]: 1 x 0/2 ... 10 V, Configuration: via DIP switchespa

1-channel signal conditioner, 24 V DC supply, Input bipolar current and voltage sources, Output bipolar current and voltage sources, Accuracy 0.1 %, Configurable via DIP switches and potentiometer, Connection via screw terminals, Number of channels: 1-channel, Signal type: Analog input, Rated voltage: 16.8 ... 31.2 V DC, Signal: 0/2 ... 10 mA, Signal [2]: 0/4 ... 20 mA, Signal [5]: 0/1 ... 5 V, Signal [7]: 0/2 ... 10 V, Line fault detection, Signal: 1 x 0/4 ... 20 mA, Signal [2]: 1 x -10 ... 10 mApa

1-channel signal conditioner, 24 V DC supply, Input 2-wire transmitters, Dual output 0/4 mA ... 20 mA, Signal splitter (1 input and 2 outputs), Accuracy 0.1 %, Connection via screw terminals, Number of channels: 1-channel, Signal type: Analog input, Rated voltage: 16.8 ... 31.2 V DC, Field device: 2-wire transmitter, Signal: 0/4 ... 20 mA, Signal: 1 x 0/4 ... 20 mA, splitter function (1 input and several outputs)pa

1-channel signal conditioner, 24 V DC supply, Input 2-wire transmitters, Input current and voltage sources, Dual output 0/4 mA ... 20 mA, 0/1 V ... 5 V or 0/2 V ... 10 V, Signal splitter (1 input and 2 outputs), Accuracy 0.1 %, Connection via screw terminals, Number of channels: 1-channel, Signal type: Analog input, Rated voltage: 16.8 ... 31.2 V DC, Field device: 2-wire transmitter, Signal: 0/4 ... 20 mA, Signal [2]: 0/2 ... 10 V, Signal: 2 x 0/4 ... 20 mApa

1-channel signal conditioner, 24 V DC supply, Input for 2- or 3-wire sensors or AC/DC voltage sources, Relay contact output, Timer function, Configurable by DIP switches, Connection via screw terminals, Number of channels: 1-channel, Time function, Signal type: Digital Input, Rated voltage: 16.8 ... 31.2 V DC, Field device: NAMUR sensor, Field device [2]: volt-free contact, Field device [3]: 2-wire DC sensor, Field device [4]: SN sensor, Field device [5]: S0 sensor, Field device [6]: NPN sensorpa

1-channel signal conditioner, 24 V DC supply, Thermocouple, RTD, potentiometer or mV input, Input for PTC thermistor, Current and voltage output, Line fault (LFD) and sensor burnout detection, Accuracy 0.1 %, Connection via screw terminals, Number of channels: 1-channel, Signal type: Analog input, Rated voltage: 16.8 ... 31.2 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometer, Field device [2]: Thermocouplepa

1-channel signal conditioner, Field side loop powered, Current input/output 0/4 mA ... 20 mA, Accuracy 0.1 %, Reverse polarity protection, Connection via screw terminals, Number of channels: 1-channel, Signal type: Analog input, Rated voltage: 2.2 ... 30 V DC , loop powered, Signal: 0/4 ... 20 mA, Signal: 1 x 0/4 ... 20 mApa

2-channel signal conditioner, Field side loop powered, Current input/output 0/4 mA ... 20 mA, Accuracy 0.1 %, Reverse polarity protection, Connection via screw terminals, Number of channels: 2-channel, Signal type: Analog input, Rated voltage: 2.2 ... 30 V DC , loop powered, Signal: 0/4 ... 20 mA, Signal: 2 x 0/4 ... 20 mApa
Næste sideSidste side

Tilpas Udvalg

Function principle

Number of channels

Digital Input

Analog Input

Output

Supply

Configuration

Functions

Global approvals

undefined

We value your privacy!

We and our partners are using technologies like cookies and process personal data like the IP-address or browser information in order to personalize the advertising that you see. This helps us to show you more relevant ads and improves your internet experience. We also use it in order to measure results or align our website content. Because we value your privacy, we are herewith asking for your permission to use these technologies. You can always change/withdraw your consent later by clicking on the settings button on the left lower corner of the page.

Deny all cookies

We value your privacy!

Please select the group of cookies and scripts, that you consent to.

Functional
These cookies are necessary so that you can navigate through the pages and use essential functions (e.g. login).
Analytics
We use these cookies and scripts to measure the visits and clicks on our website in order to constantly improve it.
Marketing
These cookies and similar technologies are used to provide you with personalized and therefore relevant advertising content.