Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Hent hele databladet som PDF:
Uddrag af datablad: Tekniske data for
OBT80-R101-2P1-IO-0,3M-V1
Produkt beskrivelse |
Triangulation sensor with background suppression |
General specifications |
Detection range | 10 ... 80 mm |
Detection range max. | 10 ... 100 mm |
Background suppression | starts from 100 mm |
Reference target | standard white, 100 mm x 100 mm |
Light source | LED |
Light type | modulated visible red light |
LED risk group labelling | exempt group |
Black-white difference (6 %/90 %) | approx. 5 mm |
Diameter of the light spot | approx. 6 mm at 80 mm |
Opening angle | approx. 5 ° |
Ambient light limit | EN 60947-5-2 : 40000 Lux |
Functional safety related parameters |
MTTFd | 600 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means |
Operation indicator | LED green: constantly on - power on flashing (4Hz) - short circuit flashing with short break (1 Hz) - IO-Link mode |
Function indicator | LED yellow: constantly on - object detected constantly off - object not detected |
Electrical specifications |
Operating voltage | 10 ... 30 V DC |
Ripple | max. 10 % |
No-load supply current | < 25 mA at 24 V supply voltage |
Protection class | III |
Interface |
Interface type | IO-Link ( via C/Q = BK ) |
IO-Link revision | 1.1 |
Device profile | Smart Sensor |
Device ID | 0x110507 (1115399) |
Transfer rate | COM2 (38.4 kBit/s) |
Min. cycle time | 2.3 ms |
Process data width | Process data input 1 Bit Process data output 2 Bit |
SIO mode support | yes |
Compatible master port type | A |
Output |
Switching type | C/Q - Pin4: NPN normally closed / dark-on, PNP normally open / light-on, IO-Link /Q - Pin2: NPN normally open / light-on, PNP normally closed / dark-on |
Signal output | 2 push-pull (4 in 1) outputs, short-circuit protected, reverse polarity protected, overvoltage protected |
Switching voltage | max. 30 V DC |
Switching current | max. 100 mA , resistive load |
Usage category | DC-12 and DC-13 |
Voltage drop | ≤ 1.5 V DC |
Switching frequency | 500 Hz |
Response time | 1 ms |
Conformity |
Communication interface | IEC 61131-9 |
Product standard | EN 60947-5-2 |
Approvals and certificates |
UL approval | E87056 , cULus Listed , class 2 power supply , type rating 1 |
Ambient conditions |
Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) , cable, fixed installation -25 ... 60 °C (-13 ... 140 °F) , movable cable not appropriate for conveyor chains |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) |
Mechanical specifications |
Degree of protection | IP67 / IP69 / IP69K |
Connection | 300 mm fixed cable with M12 x 1, 4-pin connector |
Material | |
| Housing | PC (Polycarbonate) |
| Optical face | PMMA |
Mass | approx. 17 g |
Dimensions | |
| Height | 31.9 mm |
| Width | 13.9 mm |
| Depth | 18.3 mm |
Cable length | 0.3 m |
Classifications
System | Classcode |
ECLASS 13.0 | 27270903 |
ECLASS 12.0 | 27270903 |
ECLASS 11.0 | 27270903 |
ECLASS 10.0.1 | 27270903 |
ECLASS 9.0 | 27270903 |
ECLASS 8.0 | 27270903 |
ECLASS 5.1 | 27270903 |
ETIM 9.0 | EC001821 |
ETIM 8.0 | EC001821 |
ETIM 7.0 | EC001821 |
ETIM 6.0 | EC001821 |
ETIM 5.0 | EC002719 |
UNSPSC 12.1 | 39121528 |
Details:
OBT80-R101-2P1-IO-0,3M-V1
Product Documentation:
OBT80-R101-2P1-IO-0,3M-V1
Design / Simulation:
OBT80-R101-2P1-IO-0,3M-V1
Approvals:
OBT80-R101-2P1-IO-0,3M-V1
Software:
OBT80-R101-2P1-IO-0,3M-V1
Tilhørende produkter:
OBT80-R101-2P1-IO-0,3M-V1
Accessories |
|
|
|
EtherNet/IP IO-Link master with 8 inputs/outputsfa |
|
|
|
|
PROFINET IO IO-Link master with 8 inputs/outputsfa |
|
|
|
|
Female cordset single-ended M12 straight A-coded, 4-pin, PUR cable greyfa |
|
|
|
|
Female cordset single-ended M12 angled A-coded, 4-pin, PUR cable greyfa |
|
|
|
|
Ethernet IO-Link module with 8 inputs/outputsfa |
|
|
|
|
Ethernet IO-Link module with 8 inputs/outputsfa |
|
|
|
|
EtherNet/IP IO-Link master with 8 inputs/outputs, DIN rail, push-in connectorsfa |
|
|
|
|
EtherNet/IP IO-Link master with 8 inputs/outputs, DIN rail, screw terminalfa |
|
|
|
|
PROFINET IO IO-Link master with 8 inputs/outputs, DIN rail, push-in terminalsfa |
|
|
|
|
PROFINET IO IO-Link master with 8 inputs/outputs, DIN rail, screw terminalfa |
|
|
|
|
IO-Link master, supply via USB port or separate power supply, LED indicators, M12 plug for sensor connectionfa |
|