General specifications |
Effective detection range | 0 ... 3500 mm |
Threshold detection range | 3500 mm |
Light source | IRED |
Light type | modulated infrared light , 950 nm |
Field height | 1800 mm |
Beam crossover | automatic, 3x/5x/7x (depending on distance between transmitter/receiver) |
Beam blanking | Defective beams are faded out after 60 s. Deactivation of the light grid upon failure of 2 adjacent beams or more than 50 % of all beams |
Beam spacing | 90 mm |
Number of beams | 61 ... 135 (dynamic) |
Opening angle | Emitter: < 20 ° , Receiver: < 6 ° |
Ambient light limit | > 100000 Lux |
Functional safety related parameters |
MTTFd | 180 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means |
Function indicator | LED red (in receiver): Illuminates after connecting operating power, out when object is detected, flashes in case of permanent interruption of 2 neighbouring beams |
Electrical specifications |
Operating voltage | 11 ... 30 V DC: max. |
Ripple | 10 % |
No-load supply current | < 180 mA |
Output |
Switching type | light-on |
Signal output | 1 PNP and 1 NPN, short-circuit protected |
Switching voltage | max. 30 V DC |
Switching current | 100 mA |
Switching frequency | < 3 Hz |
Response time | < 100 ms |
Compliance with standards and directives |
Directive conformity | |
| EMC Directive 2004/108/EC | EN 12015:2014 EN 12016:2013 |
Standard conformity | |
| Product standard | EN 60947-5-2:2007+A1:2012 IEC 60947-5-2:2007 + A1:2012 |
| Standards | EN 81-70:2003/A1:2004; Section 5.2.4 EN 81-20:2014; Section 5.3.6.2.2.1 Taking into account object detection in accordance with the datasheet specification for the monitoring field. |
Approvals and certificates |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Ambient temperature | -20 ... 55 °C (-4 ... 131 °F) |
Storage temperature | -20 ... 65 °C (-4 ... 149 °F) |
Pollution degree | Pollution Degree 2: Nonconductive pollution, temporary conductivity caused by condensation is possible |
Mechanical specifications |
Profile width | 9 mm |
Degree of protection | IP54 |
Connection | 5 m fixed cable |
Material | |
| Housing | Aluminum |
| Optical face | plastic |
Mass | 2300 g (device) |
Dimensions | |
| Width | 9 mm |
| Depth | 34 mm |
| Length | 2000 mm |
Equipment protection level Gc (nA) |
Instruction | Manual electrical apparatus for hazardous areas
|
Device category 3G (nA) | for use in hazardous areas with gas, vapour and mist |
ATEX marking | II 3 G Ex nAc op is IIC T4 |
Directive conformity | 94/9/EG |
Standards | EN 60079-0:2009 , EN 60079-15:2010 , EN 60079-28:2007 |
Installation, commissioning | Laws and/or regulations and standards governing the use or intended usage goal must be observed. The apparatus should be set up so that the housing is oriented vertically and the cable glands enter the housing from above. |
Maintenance | No modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. |
Special conditions | |
| Maximum permissible ambient temperature TUmax | 55 °C (131 °F) |
| Protection from mechanical danger | The apparatus must be protected from mechanical damage. |
| Protection of overvoltage | Precautions must be taken to prevent the rated voltage being exceeded by more than 40 % due to transient disturbances. |
| Protection from UV light | The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas. |
Equipment protection level Dc |
Instruction | Manual electrical apparatus for hazardous areas
|
Details for use in hazardous areas | Electrical apparatus for potentially explosive atmospheres |
ATEX marking | II 3 D Ex tc IIIB T80°C |
Directive conformity | 94/9/EG |
Standards | EN 60079-31:2009 |
Installation, commissioning | Laws and/or regulations and standards governing the use or intended usage goal must be observed. Only connections that are disconnected from the power supply may be unplugged. The apparatus should be set up so that the housing is oriented vertically and the cable glands enter the housing from above. |
Maintenance | No modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible. |
Special conditions | |
| Protection from mechanical danger | The apparatus must be protected from mechanical damage. |
General information |
Use in the hazardous area | see more details for the use in hazardous areas |
| Category | 3G; 3D |