Support Industrielle sensorer
Support Explosion Protection

Distance sensor OMR60M-R200-IEP-IO-V1-L

OMR60M-R200-IEP-IO-V1-L
  • Medium design with versatile mounting options
  • Space-saving distance sensors in small standardized design
  • Measuring method PRT (Pulse Ranging Technology)
  • IO-Link interface for service and process data
  • Red laser light, laser class 1
  • Analog output 4 ... 20 mA

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Hent hele databladet som PDF:


Uddrag af datablad: Tekniske data for   OMR60M-R200-IEP-IO-V1-L

Produkt beskrivelse
Universal distance sensor, measurement to reflector, IO-Link interface, measuring method PRT, measuring range up to 60 m, red laser light, laser class 1, push-pull output, analog output, M12 plug
General specifications
Measuring range0.2 ... 60 m
Reference targetOFR-500/500
Light sourcelaser diode
Light typemodulated visible red light
Laser nominal ratings
NoteLASER LIGHT , DO NOT STARE INTO BEAM
Laser class1
Wave length660 nm
Beam divergence2 mrad
Pulse length4 ns
Repetition rate300 kHz
max. pulse energy< 1.3 nJ
Measuring methodPulse Ranging Technology (PRT)
Max. Motion velocity10 m/s
Diameter of the light spot< 20 mm at 10 m
Ambient light limit10000 Lux
Resolution1 mm
Temperature influence< 0.25 mm/K
Functional safety related parameters
MTTFd> 300 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
Operation indicatorLED green:
constantly on - power on
flashing (4Hz) - short circuit
flashing with short break (1 Hz) - IO-Link mode
Function indicatorLED yellow:
constantly on - switch output active
constantly off - switch output inactive
Teach-in indicatorTeach-In : LED yellow/green; equiphase flashing; 2,5 Hz
Teach Error:LED green/yellow non equiphase flashing; 8.0 Hz
Control elementsTeach-In key
Control elements5-step rotary switch for operating modes selection
Electrical specifications
Operating voltage18 ... 30 V DC
Ripple10 % within the supply tolerance
No-load supply current< 25 mA at 24 V Operating voltage
Protection classIII
Time delay before availability< 900 ms
Interface
Interface typeIO-Link ( via C/Q = pin 4 )
IO-Link revision1.1
Device profileIdentification and Diagnosis - I&D
Smart Sensor - SSP 4.2.1
Process dataInput 6 Byte
- measurement value 4 Byte
- scaling factor 8 Bit
- signal quality 2 Bit
- switching signal 1 1 Bit
- switching signal 2 1 Bit
- diagnosis signals n Bit
- additional signals n Bit
Output 2 Bit
- sensor control function 1 Bit
- evaluation freeze 1 Bit
Vendor ID1 (0x0001)
Device ID1121042 (0x111B12)
Transfer rateCOM2 (38.4 kBit/s)
Min. cycle time4 ms
SIO mode supportyes
Output
Switching typeThe default setting is:
C/Q - Pin4: NPN normally open, PNP normally closed, IO-Link
I—Pin2: analog output 4...20 mA
Signal output1 push-pull output , 1 analog output , reverse polarity protected , overvoltage protected
Switching voltagemax. 30 V DC
Switching currentmax. 100 mA , resistive load
Usage categoryDC-12 and DC-13
Voltage drop≤ 1.5 V DC
Response time3 ms
Analog output
Output type1 current output: 4 ... 20 mA
Load resistor> 1 kΩ voltage output ; ≤ 470 Ω current output
Recovery time2 ms
Conformity
Communication interfaceIEC 61131-9 / IO-Link V1.1.3
Product standardEN 61000-6-2, EN 61000-6-3
Laser safetyEN 60825-1:2014
Measurement accuracy
Warm up time5 min
Measured value output1 ms
Average data age3 ms (default), 6 ms , 12 ms , 25 ms , 50 ms , 100 ms , adjustable
Absolute accuracytyp. ± 20 mm (including influence of temperature)
Repeat accuracy< 6 mm
Approvals and certificates
UL approvalE87056 , cULus Listed , class 2 power supply , type rating 1
CCC approvalCCC approval / marking not required for products rated ≤36 V
FDA approvalIEC 60825-1:2014 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007
Ambient conditions
Ambient temperature-30 ... 60 °C (-22 ... 140 °F)
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Mechanical specifications
Degree of protectionIP67 / IP69 / IP69K
Connection4-pin, M12 x 1 connector, 90° rotatable
Material
HousingPC (Polycarbonate)
Optical facePMMA
Massapprox. 35 g
Dimensions
Height50.6 mm
Width15 mm
Depth41.7 mm
Factory settings
Switching output 1Q1: switching signal high-active , Window mode 6000 ... 9000 mm
Switching output 2Q2: Window mode ( rising ramp ) 200 ... 5000 mm

Classifications

SystemClasscode
ECLASS 13.027270916
ECLASS 12.027270916
ECLASS 11.027270801
ECLASS 10.0.127270801
ECLASS 9.027270801
ECLASS 8.027270801
ECLASS 5.127270801
ETIM 9.0EC001825
ETIM 8.0EC001825
ETIM 7.0EC001825
ETIM 6.0EC001825
ETIM 5.0EC001825
UNSPSC 12.141111613

Details: OMR60M-R200-IEP-IO-V1-L

Informative Literature: OMR60M-R200-IEP-IO-V1-L

Language Selection:
LiteratureSprogFil typeFil størrelse
Product information R10x and R20x Series Standard Housings - All Sensing ModesENGPDF2583 KB
Application Report - Compact Design and Precise Distance Measurement up to 60 mENGPDF332 KB

Product Documentation: OMR60M-R200-IEP-IO-V1-L

Language Selection:
Product informationSprogFil typeFil størrelse
Installation and user instructions for offline parameterization of IO-Link sensorsENGPDF1788 KB
Parameter Information
IO-Link parameter documentation OMR60M-R200-IEP-IO* seriesENGPDF437 KB

Design / Simulation: OMR60M-R200-IEP-IO-V1-L

Language Selection:
CADSprogFil typeFil størrelse
CAD 3-D / CAD 3-DALLSTP1499 KB

Approvals: OMR60M-R200-IEP-IO-V1-L

Language Selection:
CertificatesCertifikat nr.SprogFil typeFil størrelse
Canada USA UL Ordinary LocationUL-US-L87056-11-41301991-3 / UL-CA-L87056-31-41301991-3ALLPDF1806 KB
Declaration of Conformity
EU Declaration of Conformity (P+F)TDOC-7485_DANDANPDF219 KB
UK Declaration of Conformity (P+F)TDOC-7486_ENGENGPDF195 KB

Software: OMR60M-R200-IEP-IO-V1-L

Language Selection:
Device Description Files/DriversUdgivelses infoFil typeFil størrelse
IODD for OMR60M-R200-IEP-L series / IODD für OMR60M-R200-IEP-L SerieV1.00.001 / 2023-10-30ZIP274 KB
DTM / DTMZIP16922 KB
Software Tools
IO-Link Offline Parameterization Tool / IO-Link Offline-ParametriertoolV1.00.006 / 2022-07-10ZIP96138 KB

Tilhørende produkter: OMR60M-R200-IEP-IO-V1-L

Accessories

Female connector M12 straight A-coded 4-pin, for cable diameter 6 - 8 mm, field-attachablefa

Female connector M12 angled A-coded 4-pin, for cable diameter 6 - 8 mm, field-attachablefa

Female cordset single-ended M12 straight A-coded, 4-pin, PUR cable greyfa

Female cordset single-ended M12 angled A-coded, 4-pin, PUR cable greyfa
M12 protective cap set (connector + socket) for series LS610 / LS611fa
IO-Link master, supply via USB port or separate power supply, LED indicators, M12 plug for sensor connectionfa
Mounting aid for round steel ø 12 mm or sheet 1.5 mm ... 3 mmfa
Reflective tape 100 mm x 100 mmfa
Reflective tapefa
Universal DTM host platform, For all DTMs of Pepperl+Fuchs, Approved FDT/DTM technology, Free of charge, Download from Pepperl+Fuchs websitepa

Discover the SmartRunner laser profile sensors equipped with a unique combination of light section technology and a 2-D vision sensor with integrated LEDs …

The R2000 provides reliable and extremely precise measuring results—with a gapless all-around visibility of 360° ...

Measuring in 3-D or at high speed: The R2300 series offers the right LiDAR sensor for every challenge. Learn more about the advantages, the technology, and the application areas ...

R10x and R20x series photoelectric sensors

For the first time, a consistent solution range of photoelectric functional principles and innovative technologies is available in identical housings. Users benefit from a uniform operating concept across the entire portfolio. Discover the R100, R101, R103, R200 and R201 series ...

With state-of-the-art technologies, the distance sensors offer the highest levels of precision and reliability ...