Select Your Country

Go to global website

KLD2-FBPS-1.25.360 Fieldbus Power SupplyFieldConnex® Fieldbus

Key Benefits at a Glance

  • Output: 25 ... 27 V/360 mA
  • For most fieldbus applications
  • High-power trunk for high device count and long cable lengths
  • Installation in Zone 2/Class I, Div. 2
  • For FOUNDATION Fieldbus H1
  • Fixed, high-availability terminator
  • No spacing required between modules

Show more

FieldConnex® interface
Approval
Product Compliance: Europe – CE
FOUNDATION Fieldbus interface
Note

All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

EN
  • DE
  • EN

Technical data of KLD2-FBPS-1.25.360

Fieldbus Power Supply
Installation in hazardous areaZone 2 / Div. 2
ConnectionPower Rail or terminals 8+, 11+; 9-, 12-
Rated voltageUr19.2 ... 35 V DC
Rated currentIr630 ... 340 mA
Power dissipationtyp. 2,0 W
Number of segments1
Connectionterminals 3+, 6+; 2-, 5-; 1S, 4S (S=screen connection)
Rated voltageUN25 ... 28 V
Rated currentIN360 mA
Fieldbus segment/Supplyfunctional insulation acc. to IEC 62103, rated insulation voltage 250 V AC
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
Electromagnetic compatibilityNE 21:2006
Degree of protectionIEC/EN 60529
Fieldbus standardIEC 61158-2, ISA S 50.02 part 2
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity< 95 % non-condensing
Shock resistance15 g 11 ms
Vibration resistance1 g , 10 ... 150 Hz
Pollution degreemax. 2, according to IEC 60664
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3
Connection typescrew terminal , pluggable
Core cross sectionup to 2.5 mm2
Housing20 mm x 115 mm x 107 mm
Housing materialPolycarbonate
Degree of protectionIP20
Massapprox. 210 g
MountingDIN rail mounting
CertificateTÜV 06 ATEX 553079 X
MarkingEx-Hexagon II 3G Ex ec IIC T4 Gc
Directive conformity
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018
FM approval
FM certificateFM 19 US 0015 X and FM 19 CA 0011 X
FM markingClass I, Division 2, Groups A, B, C, D, T4 / Class I, Zone 2, AEx/Ex ec IIC T4
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
General Notes