Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Lataa koko tietolomake PDF-tiedostona:
Tuotekuvaus |
---|
Single or multi-beam light curtain for individual protection according to DIN 18650/EN16005 |
General specifications | ||
---|---|---|
Detection range min. | 0 ... 1500 mm | |
Detection range max. | 0 ... 2500 mm | |
Reference target | Minimum degree of reflection of the floor: 6 % Minimum degree of reflection to objects being detected: 0 % |
|
Light source | IRED | |
Light type | modulated infrared light 875 nm | |
Black-white difference (6 %/90 %) | < 2 % at 2000 mm sensor range | |
Number of beams | 1 (number of built-in sensor modules AIR) | |
Operating mode | Background evaluation | |
Diameter of the light spot | 1.1 cm x 8.3 cm at 2000 mm sensor range | |
Resolution | Reference object CA DIN 186850-1/EN 16005 in all applicable locations | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 1 | |
Performance level (PL) | PL c | |
Category | Cat. 2 | |
MTTFd | 880 a per module | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 90 % | |
Indicators/operating means | ||
Function indicator | LED red/green | |
Control elements | Sensing range adjuster ; Adjuster for edge monitoring left/right | |
Electrical specifications | ||
Operating voltage | 24 V DC +/- 20 % | |
No-load supply current | 75 mA | |
Input | ||
Test input | active at U = 11 V DC at 30 V DC inactive at U = -3 V DC at 5 V DC | |
Output | ||
Switching type | Relay de-energized at object inside the scanning range | |
Signal output | Relay, 1 alternator | |
Switching voltage | 5 V ... 30 V AC/DC | |
Switching current | max. 300 mA | |
Response time | ≤ 70 ms | |
Conformity | ||
Functional safety | ISO 13849-1 | |
Product standard | EN 12978 ; EN 16005 ; DIN 18650 | |
Approvals and certificates | ||
CCC approval | CCC approval / marking not required for products rated ≤36 V | |
TÜV approval | TÜV NORD | |
Ambient conditions | ||
Ambient temperature | -10 ... 50 °C (14 ... 122 °F) | |
Relative humidity | Humidity at 20 °C: < 90 % Humidity at 60 °C: < 50 % |
|
Mechanical specifications | ||
Housing length L | 900 mm | |
Mounting height | max. 2500 mm | |
Degree of protection | IP52 , IP54 Optional (with special seal) | |
Connection | screw terminals ; Cable cross-section 0.3 mm2 ... 1.3 mm2 (AWG26-16), single-stranded/multistranded CU | |
Material | ||
Housing | aluminum / ABS | |
Optical face | PMMA | |
Dimensions | ||
Height | 42 mm | |
Depth | 37 mm | |
Length | 900 mm | |
Cable length | max. 30 m | |
Note | Safety fuse ≤ 1 A (slow-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. |
System | Classcode |
---|---|
ECLASS 13.0 | 27270913 |
ECLASS 12.0 | 27270913 |
ECLASS 11.0 | 27270913 |
ECLASS 10.0.1 | 27270913 |
ECLASS 9.0 | 27270913 |
ECLASS 8.0 | 27270913 |
ECLASS 5.1 | 27270903 |
ETIM 9.0 | EC002550 |
ETIM 8.0 | EC002550 |
ETIM 7.0 | EC002550 |
ETIM 6.0 | EC002550 |
ETIM 5.0 | EC001821 |
UNSPSC 12.1 | 39121528 |
The TopScan-S is a presence sensor for automatic revolving doors that operates according to the active infrared principle in background evaluation, and can be installed for mobile use in addition to static use. The modular structure consisting of master and slave modules means that the systems can be configured for different door panel widths up to 1400 mm. Up to 7 individually adjustable beams can be used in one device. This ensures test object detection across the entire door width. The sensors are certified according to the current DIN 18650/EN 16005 standard and, in conjunction with an appropriate, safe controller, fulfill all requirements for testable active opto-electronic protective devices (AOPDs) in Category 2.
We are sorry, there are no documents for your language selection. Please select another language. |
Brief Instructions | Kieli | Tiedostotyyppi | Tiedoston koko |
---|---|---|---|
Brief Instructions - for Adjusting TopScan-S / Kurzanleitung - zur Einrichtung des TopScan-S | ALL | 471 KB | |
Hints for installation of moduls AIR16-S and AIR17-S on device TopScan-S / Einstellhinweise zur Einrichtung der Module AIR16-S und AIR17-S beim Gerät TopScan-S | ALL | 264 KB | |
Manuals | |||
Manual | ENG | 2122 KB |
CAD | Kieli | Tiedostotyyppi | Tiedoston koko |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 1067 KB |
CAD Portal / CAD Portal | ALL | LINK | --- |
Certificates | Sertifikaatin nro | Kieli | Tiedostotyyppi | Tiedoston koko |
---|---|---|---|---|
/cert/cert0951c.pdf | 44 780 13 095706 | ALL | 109 KB | |
Europe TUV Nord EC-Type Exam. Certificate Functional Safety | 44 205 13 095705 | ALL | 56 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|