Yhteydenotto, Koneautomaatio
+358 20 7861 290
Yhteydenotto, Prosessiautomaatio
+358 20 7861 291

Safe evaluation unit PUS-F161-B31-WCS

PUS-F161-B31-WCS
  • FailSafe over EtherCAT® (FSoE)
  • Certified up to SIL 3 according to IEC 61508 and up to PLe according to EN 13849-1
  • Safe evaluation unit for WCS3B-LS221-U1 and WCS3B-LS221-U2
  • Reliable evaluation of position and speed

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Lataa koko tietolomake PDF-tiedostona:


Ote tietolomakkeesta: Tekniset tiedot  PUS-F161-B31-WCS

Tuotekuvaus
Safe evaluation unit for position and speed monitoring for WCS read heads;
EtherCAT with FSoE protocol
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Performance level (PL)PL e
CategoryCat. 4
Mission Time (TM)20 a
PFH12.6 E-9
Supply
Rated voltage24 V DC
Rated current2 A
Power consumption≤ 6.8 W
Indicators/operating means
LED indicationsee manual
Interface
ProtocolEtherCAT® , FailSafe over EtherCAT® (FSoE)
Input
Number14
Input typesafe digital inputs
Input current20 mA Type 1 according to IEC 61131-2
Output
Numberpp-switching: 4 (configurable via SafePLC)
pn-switching: 2 (configurable via SafePLC)
Number/Type2x Relay output
2x Auxiliary output 250 mA
2x Pulse output (clock output) 250 mA
Output typesafe digital outputs
Switching current2 A
Ambient conditions
Ambient temperature0 ... 50 °C (32 ... 122 °F)
Storage temperature-25 ... 70 °C (-13 ... 158 °F)
Relative humidity5 % - 85 %
Altitudemax. 2000 m
Mechanical specifications
Connection typeInputs/Outputs screw terminals pluggable
Ethernet RJ45
Read head RS-485
Degree of protectionIP20
Connectionat screw terminals
min. Connection cross section : 0,2 mm2 / 24 AWG
max. Connection cross section : 2.5 mm2 / 12 AWG
Mass490 g
Dimensions
Height100 mm
Width90 mm
Length115 mm
MountingDIN mounting rail

Classifications

SystemClasscode
ECLASS 13.027270991
ECLASS 12.027270991
ECLASS 11.027270791
ECLASS 10.0.127270791
ECLASS 9.027270791
ECLASS 8.027270791
ECLASS 5.127270791
ETIM 9.0EC001852
ETIM 8.0EC001852
ETIM 7.0EC001852
ETIM 6.0EC001852
ETIM 5.0EC001852
UNSPSC 12.141111945

Details: PUS-F161-B31-WCS

Function

The PUS-F161-B**-WCS safe evaluation unit can be used to perform safety shutdowns and safety functions. The device can calculate safe position and velocity data for an axis using the data from the WCS3B-LS221-U1 and WCS3B-LS221-U2 read heads.

Product Documentation: PUS-F161-B31-WCS

Language Selection:
Brief InstructionsKieliTiedostotyyppiTiedoston koko
Installation InstructionsENGPDF11966 KB
Safety and Security Documentation
KäyttöohjeFINPDF150 KB
Manuals
Error listENGPDF1740 KB

Approvals: PUS-F161-B31-WCS

Language Selection:
CertificatesSertifikaatin nroKieliTiedostotyyppiTiedoston koko
TUV Rheinland Functional Safety CertificateReg.-Nr.: 01/205/5910.00/22ALLPDF406 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitätserklärung (P+F)DOC-6813AALLPDF34 KB

Software: PUS-F161-B31-WCS

Language Selection:
Device Description Files/DriversJulkaisutiedotTiedostotyyppiTiedoston koko
EDS / EDSZIP8 KB
Software Tools
Software tool / Software ToolZIP146704 KB

Liitännäistuotteet: PUS-F161-B31-WCS

Kit
Kit consisting of a safe evaluation unit with fieldbus connection (EtherCAT® with FSoE protocol) and two safeWCS/PUS read heads, FailSafe over EtherCAT® (FSoE), Certified up to SIL 3 according to IEC 61508 and up to PLe according to EN 13849-1, Safe evaluation unit with WCS3B-LS221-U1 and WCS3B-LS221-U2, Reliable evaluation of position and speedfa
Accessories
License dongle for safeControl Expertfa
Parameterization adapter for parameterization and analysis of the PUS evaluation unitfa
DeviceNet/CANOpen bus cable M12 socket straight A-coded 4-pin to M12 plug straight A-coded 8-pin, PUR cable 4-core twisted pairs black, shielded, UL approved, drag chain suitable, outdoorfa