General specifications |
Sensing range | 30 ... 500 mm |
Adjustment range | 50 ... 500 mm |
Dead band | 0 ... 30 mm |
Standard target plate | 100 mm x 100 mm |
Transducer frequency | approx. 380 kHz |
Response delay | approx. 50 ms |
Indicators/operating means |
LED green | solid: Power-on flashing: program function object detected |
LED yellow | solid: switching state switch output flashing: program function |
LED red | normal operation: "fault" program function: no object detected |
Electrical specifications |
Operating voltage | 10 ... 30 V DC , ripple 10 %SS |
No-load supply current | ≤ 50 mA |
Input/Output |
Synchronization | bi-directional 0 level -UB...+1 V 1 level: +4 V...+UB input impedance: > 12 KOhm synchronization pulse: ≥ 100 µs, synchronization interpulse period: ≥ 2 ms |
Synchronization frequency | |
| Common mode operation | max. 95 Hz |
| Multiplex operation | ≤ 95 Hz / n , n = number of sensors , n ≤ 5
|
Input |
Input type | 1 program input, operating range 1: -UB ... +1 V, operating range 2: +4 V ... +UB input impedance: > 4.7 kΩ; program pulse: ≥ 1 s |
Output |
Output type | 1 switch output NPN , Normally open/closed , programmable |
Rated operating current | 200 mA , short-circuit/overload protected |
Voltage drop | ≤ 2.5 V |
Repeat accuracy | ≤ 0.5 % of switching point |
Switching frequency | ≤ 10 Hz |
Range hysteresis | 1 % of the set operating distance |
Temperature influence | < 2 % of far switch point |
Compliance with standards and directives |
Standard conformity | |
| Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 |
Approvals and certificates |
UL approval | cULus Listed, General Purpose |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
Ambient conditions |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications |
Connection type | Connector plug M12 x 1 , 5-pin |
Degree of protection | IP65 |
Material | |
| Housing | nickel plated brass; plastic components: PBT |
| Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam |
Mass | 135 g |
Dimensions | |
| Length | 94 mm |
| Diameter | 30 mm |
Factory settings |
Output | Switch point A1: 60 mm Switch point A2: 525 mm output function: Window mode output behavior: NO contact |