Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Lataa koko tietolomake PDF-tiedostona:
General specifications | ||
---|---|---|
Type | sensor for conductive limit value detection | |
Equipment architecture | A measuring system consists of a rod electrode HR-6**1** with electrode relay KFA6-ER 1.6, KFD2-ER 1.6, KFD2-ER-Ex1.W.LB or KFA6-ER-Ex1.W.LB. |
|
Series | HR-6**1** | |
Input | ||
Measured variable | measuring voltage directly from the electrode relay | |
Output | ||
Output signal | electrode relay creates switch signal corresponding to the selected responsiveness. | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2006 , EN 61326-2-3:2006 | |
Conformity | ||
Degree of protection | IEC 60529:2001 | |
Operating conditions | ||
Process conditions | ||
Process temperature | process connection 6: <= 150 °C (423 K) process connection 7: <= 90 °C (363 K) process connection 8: <= 150 °C (423 K) |
|
Process pressure (static pressure) | process connection 6: ≤ 30 bar process connection 7: ≤ 16 bar process connection 8: ≤ 6 bar |
|
Mechanical specifications | ||
Degree of protection | IP65 with terminal box IP52 with plug connector |
|
Connection | terminals in plug connector or in terminal box plug connector: terminal, max. 1 mm2 terminal box: terminal, max. 2.5 mm2 |
|
Material | housing: stainless steel 1.4571/316Ti, PP or PTFE process connection: stainless steel 1.4571/316Ti, PP or PTFE electrode rod: stainless steel 1.4571/316Ti, Hastelloy C, titanium or tantalum |
|
Dimensions | housing: max. Ø43 mm (1.7 inch), height max. 55 mm (2.2 inch) rod: length L max. 3000 mm (10 foot) |
|
Process connection | thread G1/2 to ISO 228 | |
General information | ||
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
System | Classcode |
---|---|
ECLASS 13.0 | 27200507 |
ECLASS 12.0 | 27200507 |
ECLASS 11.0 | 27200507 |
ECLASS 10.0.1 | 27200507 |
ECLASS 9.0 | 27200507 |
ECLASS 8.0 | 27200507 |
ECLASS 5.1 | 27200507 |
ETIM 9.0 | EC001447 |
ETIM 8.0 | EC001447 |
ETIM 7.0 | EC001447 |
ETIM 6.0 | EC001447 |
ETIM 5.0 | EC001447 |
UNSPSC 12.1 | 41111950 |
An electrode relay provides the measuring AC voltage for the electrode.
If the product comes into contact with conductive batch, the measuring circuit between electrode and wall of vessel is closed and the electrode relay is switched.
Declaration of Conformity | Sertifikaatin nro | Kieli | Tiedostotyyppi | Tiedoston koko |
---|---|---|---|---|
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-3881 | ALL | 231 KB | |
Contamination Declaration | ||||
Contamination declaration / Kontaminationserklärung | ALL | 137 KB |