General specifications | ||
---|---|---|
Operating frequency | 902 … 928 MHz: USA, Canada, Mexico, Colombia Transmission licenses for other countries on request |
|
Emitted power | 50 ... 500 mW EIRP adjustable | |
UL File Number | E254700 | |
Indicators/operating means | ||
LED green | Power on | |
LED yellow | Read/write operation successful | |
LED blue | Transmission mode | |
Electrical specifications | ||
Power consumption | ≤ 7 W | |
Supply | from the IDENTControl | |
Compliance with standards and directives | ||
Standard conformity | ||
Electromagnetic compatibility | EN 301489-1 V1.9.2:2011 EN 301489-3 V1.4.1:2003 |
|
Safety | EN 60950-1:2006/A1:2010 | |
Degree of protection | EN 60529:2000 | |
Approvals and certificates | ||
UL approval | Class I, Division 1, Groups B, C, D | |
FCC approval | This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. |
|
IC approval | This device complies with Industry Canada licence-exempt RSS standard(s) and with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. |
|
Radio approval | USA: FCC IREIUH-F190-V1 Canada: IC 13-116260 Mexico: RCPPEIU 14-2030 Colombia: 201580046 |
|
Ambient conditions | ||
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) (Operation with nontransmission periods, adjustable) -25 ... 50 °C (-13 ... 122 °F) (Continuous transmission mode) |
|
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Degree of protection | NEMA Type 4, 7, 9 | |
Connection | M12 x 1 connector | |
Material | ||
Housing | diecast aluminum | |
Base | diecast aluminum | |
Mass | approx. 7720 g | |
Dimensions | ||
Height | 165 mm | |
Width | 267 mm | |
Length | 197 mm | |
Cable length | 20 m |
System | Classcode |
---|---|
ECLASS 13.0 | 27280401 |
ECLASS 12.0 | 27280401 |
ECLASS 11.0 | 27280401 |
ECLASS 10.0.1 | 27280401 |
ECLASS 9.0 | 27280401 |
ECLASS 8.0 | 27280401 |
ECLASS 5.1 | 27280401 |
ETIM 9.0 | EC002998 |
ETIM 8.0 | EC002998 |
ETIM 7.0 | EC002998 |
ETIM 6.0 | EC002998 |
ETIM 5.0 | EC002998 |
UNSPSC 12.1 | 43211710 |
The compact IUH-F190-FR2-02-20M-C1D1 read/write head operates in the UHF frequency range and is optimized for use in industrial applications involving ranges up to 1m. The device reads and writes passive tags according to EPC Generation 2 (ISO/IEC 18000-63). The read/write head can be operated in the USA, Canada, and Mexico. The read/write head complies with the respective radio regulations.
A wide range of options is supported for filtering data. The read/write head is connected to the IDENTControl interface using an M12 connector. The user can monitor the status of the read/write head using the integrated LEDs. The read/write head has a typical detection range of approx. 1 meter; this range is determined by the tag used and can be changed by adjusting the transmission power. Other influencing factors are the application-specific setup and surrounding materials, particularly metal. The read and write distances measured under ideal conditions can be found in a separate document. For the actual read and write distances under real conditions, the combination of read/write head and tag must be tested in the intended application.
This explosion-proof unit comes with a 20 m M12 straight pigtail pre-attached to the unit. The cable can be fed directly through a straight piece of conduit, or the M12 connector can be cut off and reconnected at the final destination after the cable has been fed through the conduit.
The conduit seal comes already poured so that no hazardous gasses can enter the enclosure by way of the conduit fitting. Removing the cover is not necessary but can be done if the read head IUH-F190-V1-FR2-02 needs to be replaced in the future.
Literature | Kieli | Tiedostotyyppi | Tiedoston koko |
---|---|---|---|
Product Information - RFID UHF-F190 Portfolio | ENG | 856 KB | |
Application Report - Clear Identification of Green Tires During Vulcanization | ENG | 320 KB | |
Application Report - Synchronous Detection of Various Objects on Load Carriers | ENG | 332 KB |
Brief Instructions | Kieli | Tiedostotyyppi | Tiedoston koko |
---|---|---|---|
Brief Instructions - IUH-F190-V1* | ENG | 1810 KB | |
Manuals | |||
Manual IUH-F190-V1-* | ENG | 4328 KB | |
Manual Read / Write Ranges and Passing Speeds RFID | ENG | 3640 KB |
CAD | Kieli | Tiedostotyyppi | Tiedoston koko |
---|---|---|---|
CAD 2-D / CAD 2-D | ALL | ZIP | 726 KB |
Certificates | Sertifikaatin nro | Kieli | Tiedostotyyppi | Tiedoston koko |
---|---|---|---|---|
CA Radio Approval | Canada 13-116260 | ALL | 32 KB | |
Canada, USA UL | E468231 | ALL | LINK | --- |
Canada, USA UL | CoC 2021-12-14-E468231 | ALL | 509 KB | |
Radio Approval | NYCE/CT/1343/14/TS | ALL | 131 KB | |
USA FCC Approval | USA IREIUH-F190-V1 | ALL | 64 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|