Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Lataa koko tietolomake PDF-tiedostona:
Tuotekuvaus |
---|
Radar sensor for distance and velocity measuring up to 25 m sensing range, with M12 connector |
General specifications | ||
---|---|---|
Measuring technology | FMCW | |
Measured variable | distance velocity |
|
Measuring range | ||
Distance | 0.5 ... 25 m | |
Velocity | 0.1 ... 80 m/s | |
Dead band | 0 ... 0.5 m | |
Standard target plate | corner reflector 100 mm edge length | |
Working frequency | 122.25 ... 123 GHz | |
Opening angle | < 12 ° (see characteristic curve) | |
Transmitter radiated power (EIRP) | < +20 dBm | |
Sampling rate | 1 ... 200 Hz , programmable | |
Nominal ratings | ||
Linearity error | < ± 0.1 % of full-scale value (linearity error incl. temperature drift) | |
Repeat accuracy | 1 mm | |
Resolution | distance 1 mm velocity 0.01 m/s |
|
Time delay before availability | ≤ 400 ms | |
Functional safety related parameters | ||
Performance level (PL) | up to PL c | |
MTTFd | 310 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | up to 60 % , see functional safety manual | |
Indicators/operating means | ||
LED yellow | object within measuring range | |
LED red/green | CANopen status display | |
Electrical specifications | ||
Operating voltage | 9 ... 32 V | |
No-load supply current | ≤ 100 mA | |
Power consumption | typ. 0.4 W , max. 1 W | |
Interface | ||
Interface type | CANopen | |
Process data | distance velocity signal quality cycle counter |
|
Node ID | 1 ... 127 , programmable | |
Transfer rate | 125 kBit/s , 250 kBit/s , 500 kBit/s , 800 kBit/s , 1 MBit/s , programmable | |
Termination | external | |
Compliance with standards and directives | ||
Standard conformity | ||
Standards | EN 301489-1 EN 301489-3 EN 305550-1 EN 62368-1 EN 62311 |
|
Approvals and certificates | ||
UL approval | cULus | |
FCC approval | CFR Title 47, Part 15 FCC ID: IRE-MWL2A |
|
ISED approval | IC ID: 7037A-MWL2A HVIN/PMN: MWL2A |
|
Ambient conditions | ||
Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
Mechanical specifications | ||
Connection type | Connector plug | |
Degree of protection | IP68 / IP69 | |
Material | ||
Housing | PA-GF35 powder coated metal mounting flange |
|
Radome | PTFE | |
Connector | ||
Threading | M12 x 1 | |
Number of pins | 5 | |
Mass | 180 g | |
Dimensions | ||
Height | 40 mm | |
Width | 40 mm | |
Length | 83.3 mm | |
Factory settings | ||
Default setting | measured value "distance", measured value "velocity", signal quality, counter-2 (object 0x4000) | |
Sampling rate | 50 Hz (object 0x4000) | |
Node ID | 16 | |
Transfer rate | 250 kBit/s |
System | Classcode |
---|---|
ECLASS 13.0 | 27274501 |
ECLASS 12.0 | 27280890 |
ECLASS 11.0 | 27280890 |
ECLASS 10.0.1 | 27280890 |
ECLASS 9.0 | 27280890 |
ECLASS 8.0 | 27280890 |
ECLASS 5.1 | 27270990 |
ETIM 9.0 | EC004807 |
ETIM 8.0 | EC000138 |
ETIM 7.0 | EC000138 |
ETIM 6.0 | EC000138 |
ETIM 5.0 | EC000138 |
UNSPSC 12.1 | 39121528 |
The radar sensor series MWC25M with CANopen interface for medium distances up to 25 m range is optimized for use in industrial applications. Its compact cubic housing of the L2 series is proven in many industrial areas due to its high robustness.
Via Service Data Objects (SDOs), you can directly parameterize the radar sensor optimally for your application. Alternatively, parameterization with extended functionality is also possible using the FDT framework program PACTware and a DTM. This allows you to additionally use various evaluation and filter settings for distance and velocity values
The radar sensor operates according to the frequency modulated continuous wave (FMCW) method in the ISM band at 122 ... 123 GHz, approved for industrial use. In doing so, it emits a continuous radar signal that is varied over the frequency range of the ISM band. With this method, the sensor is able to reliably detect the distance and velocity of static and moving objects. When measuring velocity, the radar sensor detects the velocity of an object in the radial direction only, without measuring tangential velocities or velocity parts.
Literature | Kieli | Tiedostotyyppi | Tiedoston koko |
---|---|---|---|
Application Report - Collision Avoidance of AGVs in All Weather Conditions | ENG | 346 KB |
Brief Instructions | Kieli | Tiedostotyyppi | Tiedoston koko |
---|---|---|---|
Instruction leaflet / Beipackzettel | ALL | 192 KB | |
Safety and Security Documentation | |||
Functional Safety Manual | ENG | 2167 KB | |
Manuals | |||
Manual MWC25M-L2M-B16 series | ENG | 3581 KB |
CAD | Kieli | Tiedostotyyppi | Tiedoston koko |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 2867 KB |
Certificates | Sertifikaatin nro | Kieli | Tiedostotyyppi | Tiedoston koko |
---|---|---|---|---|
Canada USA UL Ordinary Location | E87056 | ALL | 576 KB | |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-7497 | ALL | 55 KB | |
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F) | DOC-7498 | ALL | 41 KB | |
FCC Suppliers Declaration of Conformity / FCC-Konformitätserklärung des Lieferanten | DOC-7546 | ALL | 42 KB |
Device Description Files/Drivers | Julkaisutiedot | Tiedostotyyppi | Tiedoston koko |
---|---|---|---|
EDS file for MWC25M-L2M-B20* / EDS-Datei für MWC25M-L2M-B20* | ZIP | 6 KB | |
DTM for MWC25M-L2M-B16* / DTM für MWC25M-L2M-B16* | V1.0.0.2 / 2023-11-02 | ZIP | 17880 KB |
Software Tools | |||
CANopen Parameterization Tool / CANopen Parametriertool | V1.00.002 / 2024-05-15 | ZIP | 216152 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|