Assistance gamme Détecteurs industriels
Support en ligne pour la protection contre le risque d’explosion

Enclosure protection vent EPV-*-GP-90

EPV-*-GP-90
  • Top or side mount configurations
  • Seamless cap
  • Friction free valve assembly
  • Spark arresting exhaust

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Téléchargez ici la fiche technique complète en PDF:


Caractéristiques techniques  EPV-*-GP-90

Description produit
Pressure relief vent for use with the Pepperl+Fuchs Bebco EPS® purge and pressurization systems
General specifications
SeriesEPV
Hazardous environmentgas or dust
Pneumatic parameters
Protective gas supplyinstrument grade air or inert gas
Pressure requirement2" ...5" wc (50.8 mm ... 127 mm wc)
Maximum pressure5" ... 7" wc (127 mm ... 177 mm wc)
Breaking pressure0.65" wc (16.5 mm wc)
Ambient conditions
Ambient temperature-29 ... 49 °C (-20.2 ... 120.2 °F)
Relative humidity5 ... 95 %, noncondensing
Mechanical specifications
MaterialBody:
cap - 3003 drawn aluminum
base - A.S.E. 306, 308 cast aluminum
mounting hub - zinc plated steel
pipe fittings - schedule 40 3003 aluminum
nameplates - Lexan®
hardware - 316 SS
Exhaust elements:
spark arrestor - 316 SS
element cap - 6061 aluminum
Valve assembly:
base - 14 Ga. machined 316 ss
seat disc - 14 Ga. machined 316 SS
hinge - Zytel® 8018, 14% glass fill
pin & rivets - 316 SS
disc adhesive - urethane epoxy
MassEPV-1-GP-90: 4 lb (1.81 kg)
EPV-2-GP-90: 4 lb (1.81 kg)
EPV-3-GP-90: 5 lb (2.27 kg)
EPV-4-GP-90: 9 lb (4.08 kg)
EPV-5-GP-90: 12 lb (5.44 kg)
MountingSide or Top Mount

Classifications

SystemClasscode
ECLASS 13.027180591
ECLASS 12.027180591
ECLASS 11.027180591
ECLASS 10.0.127293101
ECLASS 9.027293101
ECLASS 8.027293101
ECLASS 5.140050501
ETIM 9.0EC000243
ETIM 8.0EC000243
ETIM 7.0EC000243
ETIM 6.0EC000243
ETIM 5.0EC000243
UNSPSC 12.139121303

Details: EPV-*-GP-90