Assistance gamme Détecteurs industriels
Support en ligne pour la protection contre le risque d’explosion

Intrinsically safe digital multimeter 28 II EX ANZEx/IECEx

Fluke
28 II EX ANZEx/IECEx
  • CAT III 1000 V / CAT IV 600 V
  • Dustproof, waterproof (IP67)
  • Measures up to 1000V / 10A (outside of the Ex-hazardous area)
  • Min/Max/Avg and Peak capture
  • Low pass filter for accurate measurements on variable speed motor drives
  • 4½“ digit display (20,000 counts) with backlight
  • Input Alert

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Téléchargez ici la fiche technique complète en PDF:


Caractéristiques techniques  28 II EX ANZEx/IECEx

Description produit
Rugged and intrinsically safe multimeter
General specifications
Measuring range
DC voltage0.1 mV to 1000 V
Accuracy: ± (0.05 % + 1)
AC voltage0.1 mV to 1000 V
Accuracy: ± (0.7 % + 4)
DC current0.1 µA to 10 A
Accuracy: ± (0.2 % + 4)
AC current0.1 µA to 10 A
Accuracy: ± (1.0 % + 2)
Resistor0.1 Ω to 50 MΩ
Accuracy: ± (0.2 % + 1)
Conductivity60.00 nS
Accuracy: ± (1.0 % + 10)
Diode test2.0 V
Accuracy: ± (2.0 % + 1)
Duty cycle0.0 % to 99.9 %
Accuracy: Within ± (0.2 % per kHz + 0.1 %) for rise times <1 µs
Display count rate6,000 counts / 19,999 counts in high-resolution
Capacitance10 nF to 9999 µF
Accuracy: ± (1.0 % + 2)
Frequency0.5 Hz to 199.99 kHz
Accuracy: ± (0.005 % + 1)
Temperature-200 °C to +1090 °C (-328 °F to +1994 °F)
Accuracy: ± (1.0 % + 10) °C [± (1.0 + 10) °F]
 
 
Error: % of reading + number of digits
Indicators/operating means
DisplayLC display with backlight
Electrical specifications
Battery type3x AAA, type-proofed
Operating durationapprox. 400 h
Ambient conditions
Ambient temperatureDifferent temperature ranges result from the type-tested batteries used.
Storage temperature-40 ... 60 °C (-40 ... 140 °F) , without batteries
Mechanical specifications
Degree of protectionIP67
Massapprox. 690 g
Dimensionsapprox. 210 mm x 100 mm x 64 mm (with holster)
International approvals
IECEx approval
IECEx certificateIECEx PTB 11.0080X
IECEx markingEx ia IIC T4 Gb
Ex ia I Ma
ANZEx approval
ANZEx certificateANZEx 24.3004X
ANZEx markingEx ia I Ma
Ex ia IIC T4 Gb
General information
NoteRemarks:
Measurement inside the hazardous area: Ui ≤ 65V, Ii ≤ 5A
Measurement outside the hazardous area: Ui ≤ 1000V, Ii ≤ 10A
Scope of deliveryFluke 28 II EX
Ex-holster
Alligator clips AC175
Test leads TL175
Batteries
Documentation

Classifications

SystemClasscode
ECLASS 13.027200390
ECLASS 12.027200390
ECLASS 11.027200390
ECLASS 10.0.127200390
ECLASS 9.027200390
ECLASS 8.027200390
ECLASS 5.127200390
ETIM 9.0EC000069
ETIM 8.0EC000069
ETIM 7.0EC000069
ETIM 6.0EC000069
ETIM 5.0EC000069
UNSPSC 12.141113630

Details: 28 II EX ANZEx/IECEx

Product Documentation: 28 II EX ANZEx/IECEx

Language Selection:
Safety and Security DocumentationLangueType de fichierTaille
Safety Note / SicherheitshinweisALLPDF109 KB

Approvals: 28 II EX ANZEx/IECEx

Language Selection:
CertificatesIdentificationLangueType de fichierTaille
Test SafeANZEx 24.3004XALLPDF499 KB
Worldwide PTB IECEx Certificate of ConformityIECEx PTB 11.0080XALLLINK---
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitätserklärung (P+F)DOC-5320AALLPDF89 KB

Produits associés : 28 II EX ANZEx/IECEx

Accessories
Replacement protection module 440mA for Fluke 28 II EXpa
Industrial surface temperature probe for Fluke 28 II Expa
Leather case with carrying strap for Fluke 28 II Expa
AC current clamp for Fluke 28 II Expa
Test leads with adjustable length test tips for Fluke 28 II Expa