Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Ladda ned datablad som PDF::
Utdrag ur datablad: Tekniska data för
VDM18-300/20/88/122/151
Product Description |
Universal distance sensor, measurement to object, 300 mm detection range, red laser light, laser class 2, RS485 interface, 2 x PNP outputs, analog output, M12 plug |
General specifications |
Measuring range | 80 ... 300 mm |
Light source | laser diode typ. service life 50,000 h at Ta = +40 °C |
Light type | modulated visible red light |
Laser nominal ratings | |
| Note | LASER LIGHT , DO NOT STARE INTO BEAM |
| Laser class | 2 |
| Wave length | 650 nm |
Light spot representation | approx. 2 mm x 4.5 mm at 300 mm |
Measuring method | Laser triangulation |
Ambient light limit | ≤ 5000 Lux |
Nominal ratings |
Linearity error | 0.25 % of the measuring range |
Repeat accuracy | < 0.25 % of the measured value |
Resolution | < 0.1 % of the measuring range |
Temperature drift | < 0.02 % / °C |
Indicators/operating means |
Operation indicator | LED green |
Function indicator | 2 yellow LEDs: Switching status (each output) , 4 green LEDs: Operating mode |
Control elements | Control panel : Adjuster for switch point , Operating mode , Analog output ( S - Set , T - Toggle ) |
Parameterization indicator | LED red |
Electrical specifications |
Operating voltage | 18 ... 30 V DC |
No-load supply current | ≤ 40 mA at 24 V DC |
Protection class | II , rated voltage ≤ 50 V DC |
Time delay before availability | ≤ 300 ms |
Interface |
Interface type | RS-485 |
Output |
Interfaces | RS-485 |
Signal output | 2 PNP outputs, independent , short-circuit protected, reverse polarity protected |
Switching current | max. 100 mA |
Measurement output | 1 analog output 4 ... 20 mA, short-circuit/overload protected , Rmax = 500 Ohm |
Switching frequency | ≤ 1 kHz |
Response time | 0.4 ms |
Compliance with standards and directives |
Directive conformity | |
| EMC Directive 2004/108/EC | EN 60947-5-2 |
Standard conformity | |
| Laser class | DIN EN 60825-1:2008, IEC 60825-1:2007 |
Approvals and certificates |
UL approval | cULus Listed |
Ambient conditions |
Ambient temperature | -10 ... 60 °C (14 ... 140 °F) |
Storage temperature | -20 ... 80 °C (-4 ... 176 °F) |
Mechanical specifications |
Degree of protection | IP67 |
Connection | M12 connector, 8-pin |
Material | |
| Housing | ABS , impact resistant |
| Optical face | PMMA |
Mass | approx. 43 g |
Dimensions | |
| Height | 50 mm |
| Width | 17 mm |
| Depth | 50 mm |
Classifications
System | Classcode |
ECLASS 13.0 | 27270916 |
ECLASS 12.0 | 27270916 |
ECLASS 11.0 | 27270801 |
ECLASS 10.0.1 | 27270801 |
ECLASS 9.0 | 27270801 |
ECLASS 8.0 | 27270801 |
ECLASS 5.1 | 27270801 |
ETIM 9.0 | EC001825 |
ETIM 8.0 | EC001825 |
ETIM 7.0 | EC001825 |
ETIM 6.0 | EC001825 |
ETIM 5.0 | EC001825 |
UNSPSC 12.1 | 41111613 |
Details:
VDM18-300/20/88/122/151
Product Documentation:
VDM18-300/20/88/122/151
Design / Simulation:
VDM18-300/20/88/122/151
Approvals:
VDM18-300/20/88/122/151
Software:
VDM18-300/20/88/122/151
Associated Products:
VDM18-300/20/88/122/151
Accessories |
|
|
|
Mounting accessory, distance measuring devices Series VDM18fa |
|
|
|
|
Mounting accessory, distance measuring devices Series VDM18fa |
|